{"title":"Facnor EC Relay Box — Installation Manual","description":"\u003clink rel=\"stylesheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/om-manual-v2.css\"\u003e\u003cstyle\u003e.mpom .om-tbl.nw td+td{white-space:nowrap}.mpom details.om-dd{position:relative;margin:0}.mpom details.om-dd\u003esummary{list-style:none;cursor:pointer}.mpom details.om-dd\u003esummary::-webkit-details-marker{display:none}.mpom .om-dd-menu{position:absolute;left:0;top:calc(100% + 6px);min-width:100%;width:max-content;max-width:360px;background:#fff;border:1px solid #e3e5e8;border-radius:6px;box-shadow:0 8px 24px rgba(0,0,0,.14);z-index:30;padding:6px}.mpom .om-dd-menu a{display:flex;justify-content:space-between;align-items:center;gap:14px;padding:10px 12px;border-radius:4px;font-size:14px;font-weight:600;color:#2a2b2a!important;text-decoration:none!important}.mpom .om-dd-menu a:hover{background:#f5f6f8}.mpom .om-dd-menu small{font-weight:400;color:#5f6368;white-space:nowrap}\u003c\/style\u003e\u003cdiv class=\"mpom\"\u003e\n\u003cdiv class=\"om-head\"\u003e\n\u003cdiv\u003e\n\u003cspan class=\"om-tag\"\u003eINSTALLATION MANUAL\u003c\/span\u003e\u003cp class=\"om-lead\"\u003eHow to set the voltage, wire and tighten the Facnor relay box used with EC electric headsail furlers and FXE electric code-sail furlers, run the furler from the box in an emergency, and troubleshoot it.\u003c\/p\u003e\n\u003cdiv class=\"om-box\"\u003e\n\u003cdiv class=\"om-row\"\u003e\n\u003cspan\u003eDocument\u003c\/span\u003e\u003cb\u003eFacnor EC Relay Box Installation Manual\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-row\"\u003e\n\u003cspan\u003eFormat\u003c\/span\u003e\u003cb\u003ePDF · 5 pages · 1.0 MB\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-row\" style=\"border-bottom:0\"\u003e\n\u003cspan\u003eLanguage\u003c\/span\u003e\u003cb\u003eEnglish\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-acts\"\u003e\u003ca class=\"om-btn dl\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Facnor-EC-FXE-Relay-Box-Installation-Manual.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003csvg viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2.4\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M12 4v11\"\u003e\u003c\/path\u003e\u003cpath d=\"m7 10 5 5 5-5\"\u003e\u003c\/path\u003e\u003cpath d=\"M5 20h14\"\u003e\u003c\/path\u003e\u003c\/svg\u003e Download PDF\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-toc\"\u003e\n\u003ca href=\"#om-specs\"\u003eSpecifications\u003c\/a\u003e\u003ca href=\"#om-install\"\u003eInstallation\u003c\/a\u003e\u003ca href=\"#om-use\"\u003eEmergency \u0026amp; Service\u003c\/a\u003e\u003ca href=\"#om-trouble\"\u003eTroubleshooting\u003c\/a\u003e\u003ca href=\"#om-products\"\u003eProducts\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-img\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Facnor-EC-FXE-Relay-Box-Installation-Manual-Cover.png\" alt=\"Facnor EC Relay Box — Installation Manual\" loading=\"lazy\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-specs\"\u003e\n\u003ch2 class=\"om-h\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e12–24V (open the box to choose the voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e50A permanent max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal power fuse\u003c\/td\u003e\n\u003ctd\u003e80A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal remote fuse\u003c\/td\u003e\n\u003ctd\u003e2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3 class=\"om-h3\"\u003eDelivery content\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 – Relay box and cover.\u003c\/li\u003e\n\u003cli\u003e2 – Swage terminals 25 \u0026amp; 35 mm² (towards the battery).\u003c\/li\u003e\n\u003cli\u003e3 – Swage terminals 10 \u0026amp; 6 mm² (towards the headsail or code-sail furler).\u003c\/li\u003e\n\u003cli\u003e4, 5 – Terminal caps.\u003c\/li\u003e\n\u003cli\u003e6 – Optional wireless remote receiver cable.\u003c\/li\u003e\n\u003cli\u003e7 – Plug to be connected to the wired control device.\u003c\/li\u003e\n\u003cli\u003e8 – Caps (over the emergency push-buttons).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block om-grid2\" id=\"om-install\"\u003e\n\u003ch2 class=\"om-h\"\u003eLayout, Voltage \u0026amp; Wiring\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eLayout \u0026amp; 12\/24V Setting\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLayout: battery → fitted-in battery cut-out → magneto-thermic circuit breaker → relay box → electric furling gear or electric code-sail furler; wired furl in\/out control box or wireless version.\u003c\/li\u003e\n\u003cli\u003eLoosen the 4 captive screws (A) holding the cover; do not try to remove them.\u003c\/li\u003e\n\u003cli\u003eFuse (B) is the voltage selector. (C) is the remote control circuit fuse, (D) the main power fuse.\u003c\/li\u003e\n\u003cli\u003eNever let the cover hang by the electric wires.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eWiring \u0026amp; Tightening\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRespect polarity: the electronic components will be destroyed if you don't.\u003c\/li\u003e\n\u003cli\u003eBattery terminals and drive unit (M) terminals: 10 Nm max. Inside the box: 2.2 Nm max.\u003c\/li\u003e\n\u003cli\u003eExcessive tightening torque irreversibly destroys the internal electronic main board; this damage is not covered by the warranty.\u003c\/li\u003e\n\u003cli\u003eConnect the battery (via the circuit breaker), the headsail or code-sail furler, and the wired control circuit or optional wireless remote control as shown in the PDF.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-use\"\u003e\n\u003ch2 class=\"om-h\"\u003eEmergency Operation \u0026amp; Precautions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIf the remote control circuit fails, you can run the furler clockwise and anti-clockwise from the relay box: remove the caps (8) over the push-buttons (9) and furl in or out. Refit the caps after use.\u003c\/li\u003e\n\u003cli\u003eThe emergency circuit is independent from the control circuit, so a blown control fuse does not affect it. In emergency mode make sure all safety conditions are respected before handling.\u003c\/li\u003e\n\u003cli\u003eInstallation and any further service must be carried out by a professional, following the rules for electrical equipment and the conditions of use on board.\u003c\/li\u003e\n\u003cli\u003eIf you must disassemble, never handle anything under power.\u003c\/li\u003e\n\u003cli\u003eSerial number: the label gives the box number and the year of manufacture (example: relay box No 002, year 2019).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-trouble\"\u003e\n\u003ch2 class=\"om-h\"\u003eTroubleshooting\u003c\/h2\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eProblem\u003c\/th\u003e\n\u003cth\u003ePossible reason\u003c\/th\u003e\n\u003cth\u003eSolution\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe furler doesn't work, or no longer works after the sail has been fitted\u003c\/td\u003e\n\u003ctd\u003eCircuit breaker activated\u003c\/td\u003e\n\u003ctd\u003eMake sure the electrical circuit is fully safe before resetting the circuit breaker.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent overload\u003c\/td\u003e\n\u003ctd\u003eCheck that the main power fuse (D) is not blown.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eThe relay box is set to the wrong voltage\u003c\/td\u003e\n\u003ctd\u003eMake sure the relay box is set to the correct voltage (C – 12\/24V settings).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe furler works in only one way\u003c\/td\u003e\n\u003ctd\u003eControl circuit connection error\u003c\/td\u003e\n\u003ctd\u003e1) Operate the emergency buttons, which are independent of the control circuit: if the furler works, the problem is in the control circuit. 2) Check the control options' wires are correctly connected (Optional Electric Remote Control instructions 29160050195). 3) Check the remote control fuse (C) is not blown.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"om-note\"\u003eNeed a part that isn't listed? \u003ca href=\"\/pages\/contact\"\u003eAsk us to source it\u003c\/a\u003e and quote the part number from the PDF.\u003c\/p\u003e\n\u003ch2 class=\"om-h\" id=\"om-products\"\u003eProducts in this Manual\u003c\/h2\u003e\n\u003c\/div\u003e","products":[],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/collections\/Facnor-EC-FXE-Relay-Box-Installation-Manual-Cover.png?v=1793120061","url":"https:\/\/www.mauripro.com\/collections\/owners-manuals-facnor-ec-relay-box.oembed","provider":"MAURIPRO Sailing","version":"1.0","type":"link"}