{"title":"Forespar Table Pedestal System — Installation","description":"\u003clink rel=\"stylesheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/om-manual-v2.css\"\u003e\u003cstyle\u003e.mpom .om-tbl.nw td+td{white-space:nowrap}.mpom details.om-dd{position:relative;margin:0}.mpom details.om-dd\u003esummary{list-style:none;cursor:pointer}.mpom details.om-dd\u003esummary::-webkit-details-marker{display:none}.mpom .om-dd-menu{position:absolute;left:0;top:calc(100% + 6px);min-width:100%;width:max-content;max-width:360px;background:#fff;border:1px solid #e3e5e8;border-radius:6px;box-shadow:0 8px 24px rgba(0,0,0,.14);z-index:30;padding:6px}.mpom .om-dd-menu a{display:flex;justify-content:space-between;align-items:center;gap:14px;padding:10px 12px;border-radius:4px;font-size:14px;font-weight:600;color:#2a2b2a!important;text-decoration:none!important}.mpom .om-dd-menu a:hover{background:#f5f6f8}.mpom .om-dd-menu small{font-weight:400;color:#5f6368;white-space:nowrap}\u003c\/style\u003e\u003cdiv class=\"mpom\"\u003e\n\u003cdiv class=\"om-head\"\u003e\n\u003cdiv\u003e\n\u003cspan class=\"om-tag\"\u003eINSTALLATION MANUAL\u003c\/span\u003e\u003cp class=\"om-lead\"\u003eHeights, bury and set-up of the Forespar Marelon table pedestals: gas spring telescoping, non-gas telescoping and fixed height units, plus advice for large tables and care.\u003c\/p\u003e\n\u003cdiv class=\"om-box\"\u003e\n\u003cdiv class=\"om-row\"\u003e\n\u003cspan\u003eDocument\u003c\/span\u003e\u003cb\u003eForespar Table Pedestal System Installation\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-row\"\u003e\n\u003cspan\u003eFormat\u003c\/span\u003e\u003cb\u003ePDF · 1 page · 0.2 MB\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-row\" style=\"border-bottom:0\"\u003e\n\u003cspan\u003eLanguage\u003c\/span\u003e\u003cb\u003eEnglish\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-acts\"\u003e\u003cdetails class=\"om-dd\"\u003e\u003csummary class=\"om-btn dl\"\u003e\u003csvg viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2.4\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M12 4v11\"\u003e\u003c\/path\u003e\u003cpath d=\"m7 10 5 5 5-5\"\u003e\u003c\/path\u003e\u003cpath d=\"M5 20h14\"\u003e\u003c\/path\u003e\u003c\/svg\u003e Download PDF ▾\u003c\/summary\u003e\u003cdiv class=\"om-dd-menu\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Forespar-Table-Pedestal-System-Installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003eInstallation Manual\u003c\/span\u003e\u003csmall\u003ePDF · 1 p.\u003c\/small\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Forespar-Table-Pedestal-System-Standard-Dimensions.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003eStandard dimensions diagram (D107)\u003c\/span\u003e\u003csmall\u003ePDF · 1 p.\u003c\/small\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-toc\"\u003e\n\u003ca href=\"#om-specs\"\u003eDimensions\u003c\/a\u003e\u003ca href=\"#om-use\"\u003eUse \u0026amp; Care\u003c\/a\u003e\u003ca href=\"#om-products\"\u003eProducts\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-img\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Forespar-Table-Pedestal-System-Installation-Cover.png\" alt=\"Forespar Table Pedestal System — Installation\" loading=\"lazy\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-specs\"\u003e\n\u003ch2 class=\"om-h\"\u003ePedestal Types \u0026amp; Heights\u003c\/h2\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003ePart no.\u003c\/th\u003e\n\u003cth\u003eDimensions (base to base)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas spring telescoping\u003c\/td\u003e\n\u003ctd\u003e#161001 \u0026amp; #161004\u003c\/td\u003e\n\u003ctd\u003eStandard bury 5\" → 26\" maximum height, 13\" compressed height\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-gas telescoping\u003c\/td\u003e\n\u003ctd\u003e#161003 \u0026amp; #161006\u003c\/td\u003e\n\u003ctd\u003eSame standard dimensions; generally 30\" maximum extended height with zero bury, 18\" compressed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFixed height\u003c\/td\u003e\n\u003ctd\u003eBases #164021 (silver coated) or #164009 (\"teak-look\")\u003c\/td\u003e\n\u003ctd\u003eUp to 29\" maximum (longest double tapered tube); most table heights are 25\" to 27\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eAll bases are 9-3\/4\" diameter with a five point fastener pattern. Bases and stop collars are molded in Marelon: no metal-to-metal contact, so no corrosion.\u003c\/li\u003e\n\u003cli\u003eBury = portion of the pedestal tube below the deck. On gas spring units the spring travel is fixed: removing 1\" of bury adds 1\" to both the overall and compressed heights; adding bury lowers them.\u003c\/li\u003e\n\u003cli\u003eNon-gas units allow more variation in bury and height, as no gas spring restricts the telescoping section.\u003c\/li\u003e\n\u003cli\u003eFixed height tubes: aluminum fluted tubing, clear anodized (silver look) or copper tone anodized (teak-look) to match the bases; 3\" (76mm) O.D. size only.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-use\"\u003e\n\u003ch2 class=\"om-h\"\u003eLarge Tables, Use \u0026amp; Care\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLarge or very heavy tables may need two pedestals: usually one gas spring and one non-gas unit, so they don't fight each other. Two gas spring units would be virtually impossible to lower.\u003c\/li\u003e\n\u003cli\u003eDo not use any lubricants on telescoping pedestals; clean with fresh, soapy water only.\u003c\/li\u003e\n\u003cli\u003eWhen lowering a gas spring unit, press down directly over the pedestal so the offset leverage of the table does not cock the tube.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"om-note\"\u003eDiagram D107 (second PDF) shows the standard dimensions on a gas spring unit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp class=\"om-note\"\u003eNeed a part that isn't listed? \u003ca href=\"\/pages\/contact\"\u003eAsk us to source it\u003c\/a\u003e and quote the part number from the PDF.\u003c\/p\u003e\n\u003ch2 class=\"om-h\" id=\"om-products\"\u003eProducts in this Manual\u003c\/h2\u003e\n\u003c\/div\u003e","products":[],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/collections\/Forespar-Table-Pedestal-System-Installation-Cover.png?v=1793136069","url":"https:\/\/www.mauripro.com\/collections\/owners-manuals-forespar-table-pedestal-system.oembed","provider":"MAURIPRO Sailing","version":"1.0","type":"link"}