{"title":"Lalizas Self-Contained Breathing Apparatus SOLAS\/MED — Instructions of Use","description":"\u003clink rel=\"stylesheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/om-manual-v2.css\"\u003e\u003cstyle\u003e.mpom .om-tbl.nw td+td{white-space:nowrap}.mpom details.om-dd{position:relative;margin:0}.mpom details.om-dd\u003esummary{list-style:none;cursor:pointer}.mpom details.om-dd\u003esummary::-webkit-details-marker{display:none}.mpom .om-dd-menu{position:absolute;left:0;top:calc(100% + 6px);min-width:100%;width:max-content;max-width:360px;background:#fff;border:1px solid #e3e5e8;border-radius:6px;box-shadow:0 8px 24px rgba(0,0,0,.14);z-index:30;padding:6px}.mpom .om-dd-menu a{display:flex;justify-content:space-between;align-items:center;gap:14px;padding:10px 12px;border-radius:4px;font-size:14px;font-weight:600;color:#2a2b2a!important;text-decoration:none!important}.mpom .om-dd-menu a:hover{background:#f5f6f8}.mpom .om-dd-menu small{font-weight:400;color:#5f6368;white-space:nowrap}\u003c\/style\u003e\u003cdiv class=\"mpom\"\u003e\n\u003cdiv class=\"om-head\"\u003e\n\u003cdiv\u003e\n\u003cspan class=\"om-tag\"\u003eINSTRUCTIONS\u003c\/span\u003e\u003cp class=\"om-lead\"\u003eInstructions of use for the Lalizas Self-Contained Breathing Apparatus SOLAS\/MED 71327 (6L) and 71328 (9L): components, technical data, pre-use checks, donning and doffing, cylinder change, service intervals, charging and storage.\u003c\/p\u003e\n\u003cdiv class=\"om-box\"\u003e\n\u003cdiv class=\"om-row\"\u003e\n\u003cspan\u003eDocument\u003c\/span\u003e\u003cb\u003eLalizas Self-Contained Breathing Apparatus SOLAS\/MED Instructions of Use\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-row\"\u003e\n\u003cspan\u003eFormat\u003c\/span\u003e\u003cb\u003ePDF · 12 pages · 0.4 MB\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-row\" style=\"border-bottom:0\"\u003e\n\u003cspan\u003eLanguage\u003c\/span\u003e\u003cb\u003eEnglish\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-acts\"\u003e\n\u003ca class=\"om-btn dl\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Lalizas-Self-Contained-Breathing-Apparatus-SOLAS-MED-71327-71328-Instructions.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003csvg viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2.4\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M12 4v11\"\u003e\u003c\/path\u003e\u003cpath d=\"m7 10 5 5 5-5\"\u003e\u003c\/path\u003e\u003cpath d=\"M5 20h14\"\u003e\u003c\/path\u003e\u003c\/svg\u003e Download PDF\u003c\/a\u003e\u003ca class=\"om-btn buy\" href=\"\/collections\/lalizas-sailing-marine-safety-fire-fightning-equipment\"\u003eView Collection\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-toc\"\u003e\n\u003ca href=\"#om-specs\"\u003eTechnical Data\u003c\/a\u003e\u003ca href=\"#om-parts\"\u003eComponents\u003c\/a\u003e\u003ca href=\"#om-check\"\u003eChecks Prior to Use\u003c\/a\u003e\u003ca href=\"#om-use\"\u003eDonning \u0026amp; Doffing\u003c\/a\u003e\u003ca href=\"#om-maint\"\u003eMaintenance\u003c\/a\u003e\u003ca href=\"#om-products\"\u003eProducts\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-img\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/713271_02f81bb8-5311-4713-8eb1-c62561ca66a9.jpg?v=1773944835\" alt=\"Lalizas Self-Contained Breathing Apparatus SOLAS\/MED — Instructions of Use\" loading=\"lazy\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-specs\"\u003e\n\u003ch2 class=\"om-h\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003e71327\u003c\/th\u003e\n\u003cth\u003e71328\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eOpen circuit, positive pressure\u003c\/td\u003e\n\u003ctd\u003eOpen circuit, positive pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir supply\u003c\/td\u003e\n\u003ctd\u003eOn demand\u003c\/td\u003e\n\u003ctd\u003eOn demand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarning pressure\u003c\/td\u003e\n\u003ctd\u003e50-60Bar\u003c\/td\u003e\n\u003ctd\u003e50-60Bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking pressure\u003c\/td\u003e\n\u003ctd\u003e300Bar\u003c\/td\u003e\n\u003ctd\u003e300Bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal rated duration\u003c\/td\u003e\n\u003ctd\u003e45min\u003c\/td\u003e\n\u003ctd\u003e60min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCylinder volume\u003c\/td\u003e\n\u003ctd\u003e6L\u003c\/td\u003e\n\u003ctd\u003e9L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCylinder material\u003c\/td\u003e\n\u003ctd\u003eSteel\u003c\/td\u003e\n\u003ctd\u003eCarbon composite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;15kg\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;12kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to +65°C\u003c\/td\u003e\n\u003ctd\u003e-30°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to +60°C\u003c\/td\u003e\n\u003ctd\u003e-10°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage lifetime\u003c\/td\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv style=\"height:16px\"\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eSelf-contained open-circuit compressed air breathing apparatus with positive pressure full face mask; apparatus for fire-fighting of Type 2 tested to EN 137 (2006) and EN 136 (1998) incl. AC (1999) and AC (2003), ISO 23269-2:2011; certified to MED Directive 2014\/90 and SOLAS requirements. Approved as breathing apparatus of the fire-fighter's outfit.\u003c\/li\u003e\n\u003cli\u003eNot for use in accidents with cargoes. It is not a diving apparatus. Lalizas strongly recommends use by well-trained personnel only.\u003c\/li\u003e\n\u003cli\u003eDurations estimated at an average consumption of 40L\/min with a fully charged cylinder; workload, physical fitness, restrictive clothing, emotional stress and fatigue increase consumption.\u003c\/li\u003e\n\u003cli\u003eEach SCBA shall be used with an approved lifeline as part of the fire-fighter's outfit (FSS Code Ch.3.2.1.3), attachable by snap-hook to the harness or a separate belt.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block om-grid2\" id=\"om-parts\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eMain Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBack frame: donning cushion harness, adjustable cylinder holding Velcro webbing, rubber pad, two grooves for the high and medium pressure hoses. Flame retardant, waterproof and antistatic.\u003c\/li\u003e\n\u003cli\u003eFirst stage regulator: reduces 300bar to a constant ≈7bar and a flow of \u0026gt;350L\/min; relief valve opens above 11bar; G5\/8 connecting thread (EN144-2). High pressure hose (WP 300Bar) to the pressure gauge (0–40Mpa \/ 400Bar, readable to 1Mpa \/ 10bar) and warning whistle (sounds below 50-60bar, \u0026gt;90dB (A)); medium pressure hose (WP 20Bar) to the second stage.\u003c\/li\u003e\n\u003cli\u003eSecond stage regulator: \"on demand\" valve with ON \u0026amp; OFF buttons, fast joint on its hose, plug-in interface to the face piece, 360º rotation at the mask joint.\u003c\/li\u003e\n\u003cli\u003eFace piece: Class 3 mask for special use per EN 136:1998 + AC (2003) – visor, speech diaphragm, exhalation valve, plug-in interface, rubber straps, sealing edge, head net. Leakage requirements are unlikely to be met if facial hair or spectacle side arms pass under the facial seal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eCylinder \u0026amp; Valve\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e71327: steel cylinder 6L, working pressure 300bar (EN 1964-1).\u003c\/li\u003e\n\u003cli\u003e71328: composite cylinder 9L, working pressure 300bar (EN 1975 \u0026amp; EN 12245).\u003c\/li\u003e\n\u003cli\u003eCylinder thread for both models 18x1, 5mm (EN 144-1) (as printed); colour coded for breathing air per EN 1089-3:2001.\u003c\/li\u003e\n\u003cli\u003eCylinder valve: inlet M18X 1, 5mm (EN 144-1), outlet G5\/8 (EN 144-2), working pressure 30MPa, relief valve, rubber knob operable while wearing; the spindle cannot be completely unscrewed in normal operation.\u003c\/li\u003e\n\u003cli\u003eIf you do not use a Lalizas cylinder: it must be designed to national regulations, hold at least 1200 liter of air, and be marked with charging pressure, capacity and the inspection body stamp; the complete apparatus shall undergo practical performance tests.\u003c\/li\u003e\n\u003cli\u003eSupplied in heavy duty plastic carrying suitcases.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-check\"\u003e\n\u003ch2 class=\"om-h\"\u003eBrief Check Before Use\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eRemove the SCBA from the suitcase.\u003c\/li\u003e\n\u003cli\u003ePush the face piece lock button and detach the second stage regulator from the face piece.\u003c\/li\u003e\n\u003cli\u003ePush the \"OFF\" button of the second stage regulator.\u003c\/li\u003e\n\u003cli\u003eOpen the cylinder valve until you hear the whistle and the gauge stabilises: it must read at least 80% of the rated filling pressure (300bar), i.e. 240-300bar (±10% with ambient temperature). Close the valve and watch the gauge for 60 sec: a drop of 20bar or less (printed \"20dar\") means the system is leak-tight; more than 20bar → send it to a Lalizas authorized service station.\u003c\/li\u003e\n\u003cli\u003ePut the second stage regulator to your mouth and inhale to check the on demand valve; the whistle sounds again – check the gauge reads approximately 50 bar when it sounds.\u003c\/li\u003e\n\u003cli\u003eWhen the gauge reads zero, detach the second stage regulator from the first stage at the fast joint.\u003c\/li\u003e\n\u003cli\u003eCheck the second stage O-ring, the visor and the sealing edge for damage.\u003c\/li\u003e\n\u003cli\u003eAssemble the second stage regulator to the face piece and don the face piece.\u003c\/li\u003e\n\u003cli\u003ePlug the tube entrance with your finger and inhale: the face piece should deform towards your face. Any deficiency → authorized service station.\u003c\/li\u003e\n\u003cli\u003eDoff the face piece and reconnect the second stage regulator to the first stage at the fast joint. The SCBA is ready to use or to pack for storage.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block om-grid2\" id=\"om-use\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eFitting \u0026amp; Use\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eHarness: don it like a jacket, no twisted harness or hose; adjust the shoulder straps tight but comfortable; close the waist belt buckle and fasten the strap.\u003c\/li\u003e\n\u003cli\u003ePush the \"OFF\" button of the second stage regulator.\u003c\/li\u003e\n\u003cli\u003eOpen the cylinder valve slowly counterclockwise until fully open; listen for the whistle and check 240-300bar (at least 80%). Take extra care to have the cylinder valve fully opened during use.\u003c\/li\u003e\n\u003cli\u003eFace mask: fully extend the straps; place the lower strap over your head; pull the head-net on top of the face piece; fit the sealing edge to your face and pull the head net over the head with its loop; tighten the side straps – do not over-tighten, this can distort the seal; breathe freely.\u003c\/li\u003e\n\u003cli\u003eSeal check: take a breath and hold it, feel the flow stop, insert a finger under the seal – the demand valve should give steady flow again; remove the finger and let the mask reseal.\u003c\/li\u003e\n\u003cli\u003eAmbient air breathing: press the lock button, detach the second stage regulator and press \"OFF\"; reattach it to have device air again immediately.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eDoffing \u0026amp; After Use\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCheck how much air is left and close the cylinder valve; below 80% (240-300bar) the cylinder needs refilling.\u003c\/li\u003e\n\u003cli\u003ePull the metal buckles forward to release the head-net straps and remove the face piece.\u003c\/li\u003e\n\u003cli\u003eRelease the waist belt, slacken the shoulder straps and remove the apparatus.\u003c\/li\u003e\n\u003cli\u003eCylinder change: open the Velcro webbing and unscrew the hand-wheel connector; mark the cylinder empty or half load and send it for charging; fit the rubber protection cover on the first stage regulator. To fit a charged Lalizas cylinder (6L 300bar or 9L 300bar): place it in the webbing, remove the cover, align and screw the valve to the first stage hand wheel, fasten the webbing.\u003c\/li\u003e\n\u003cli\u003eAfter every use clean and visually inspect the apparatus; reassemble and pack when all components are thoroughly dry.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-maint\"\u003e\n\u003ch2 class=\"om-h\"\u003eMaintenance and Service\u003c\/h2\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAction\u003c\/th\u003e\n\u003cth\u003eAfter use\u003c\/th\u003e\n\u003cth\u003eEvery month\u003c\/th\u003e\n\u003cth\u003eEvery 4 months\u003c\/th\u003e\n\u003cth\u003eEvery 1 year *\u003c\/th\u003e\n\u003cth\u003eEvery 2 years\u003c\/th\u003e\n\u003cth\u003eEvery 5 years\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClean and disinfect as necessary (A)\u003c\/td\u003e\n\u003ctd\u003eX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVisual inspection (B)\u003c\/td\u003e\n\u003ctd\u003eX\u003c\/td\u003e\n\u003ctd\u003eX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharge cylinder to correct pressure (C)\u003c\/td\u003e\n\u003ctd\u003eX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction test (E)\u003c\/td\u003e\n\u003ctd\u003eX\u003c\/td\u003e\n\u003ctd\u003eX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck manufacturing date of the cylinder\u003c\/td\u003e\n\u003ctd\u003eX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck cylinder pressure\u003c\/td\u003e\n\u003ctd\u003eX\u003c\/td\u003e\n\u003ctd\u003eX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService (authorized service station)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir replacement (authorized service station)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydraulic test (D) (authorized service station)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp class=\"om-note\"\u003e* or more frequently in case of severe use.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCleaning (A): no organic solvents (acetone, white spirit, trichloroethylene or similar); do not immerse the apparatus. Back frame and straps: brush or sponge with warm soapy water, rinse, dry in clean air away from heat and sunlight. Cylinder, valve and regulators: wet cloth in hot water, then dry cloth.\u003c\/li\u003e\n\u003cli\u003eFace piece: warm fresh water (maximum 43ºC) and neutral soap, rinse, shake and dry with a cotton cloth or clean gauze (not ginned cotton); disinfect mask and sealing edge with a cotton cloth moistened in 70% isopropyl alcohol and let it evaporate away from heat and sunlight.\u003c\/li\u003e\n\u003cli\u003eVisual inspection (B): face piece and on demand valve; cylinder valve, regulator, hose, gauge and connections; straps and buckles. Don and check the straps; check visor, sealing edge, head net and rubber straps; check the second stage for wear and the ON-OFF buttons; remove the cylinder, release the remaining air and recharge to 300bar.\u003c\/li\u003e\n\u003cli\u003eCharging (C): air to EN12021; cylinder to national standards with original test date and mark; hydraulic test (D) every five years after manufacture not exceeded. Open the valve, connect the G5\/8 hand wheel of the charging hose, set the compressor to 300 bar; assemble to the apparatus 24 hours after charging; with \"OFF\" pushed, open the valve for 15 sec to check pressure, first stage and whistle; about 300 bar steady for 20 sec, then push \"ON\" to vent (search for a leak if it does not stay steady). Close the valve, vent and remove the hose, refit the plug, repack.\u003c\/li\u003e\n\u003cli\u003eFunction test (E): see the pre-use check; it should last only a few seconds.\u003c\/li\u003e\n\u003cli\u003eStorage: clean, dry, away from direct heat, dust, sunlight, extreme cold and damaging chemicals; not compressed; storage temperature -30ºC to +65ºC. Transport tightly packed in a strong box.\u003c\/li\u003e\n\u003cli\u003eLife expectancy: 10 years from date of manufacture when maintained per the instructions and national regulations and serviced annually by a Lalizas authorized service station (or more frequently in severe use).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"om-note\"\u003eLalizas safety notification: to be used only by well-trained personnel following the manufacturer's instructions; misuse can lead to injuries or even death; non-trained personnel must not use the respirators, either for safety or training. If something is not clear, do not use the equipment and contact a Lalizas representative \/ service station.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp class=\"om-note\"\u003eNeed a part that isn't listed? \u003ca href=\"\/pages\/contact\"\u003eAsk us to source it\u003c\/a\u003e and quote the part number from the PDF.\u003c\/p\u003e\n\u003ch2 class=\"om-h\" id=\"om-products\"\u003eProducts in this Manual\u003c\/h2\u003e\n\u003c\/div\u003e","products":[{"product_id":"lal-713271","title":"Lalizas Self Contained Breathing Apparatus Solas\/Med, Without Cylinder","description":"\u003cp\u003eEnsure critical safety with the \u003cb\u003eLalizas Self Contained Breathing Apparatus Solas\/Med, Without Cylinder\u003c\/b\u003e, designed for marine emergency and firefighting use. This essential SCBA unit meets strict SOLAS\/MED standards, providing reliable respiratory protection in hazardous environments when paired with your existing air cylinder. It's the perfect flexible solution for professionals needing a high-quality, compliant breathing apparatus.\u003c\/p\u003e","brand":"Lalizas","offers":[{"title":"Default Title","offer_id":50909394764082,"sku":"LAL-713271","price":667.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/713271_02f81bb8-5311-4713-8eb1-c62561ca66a9.jpg?v=1773944835"},{"product_id":"lal-71328","title":"Lalizas Self Contained Breathing Apparatus Solas\/Med 2,3Gal (9L) 300Bar","description":"\u003cp\u003eEquip your vessel with the complete \u003cb\u003eLalizas Self Contained Breathing Apparatus Solas\/Med 2,3Gal (9L) 300Bar\u003c\/b\u003e, a fully compliant SCBA system for critical marine safety. Featuring a high-capacity 9L, 300Bar cylinder, this breathing apparatus ensures extended operational time for emergency response and firefighting missions. Rely on this robust and certified system to provide essential respiratory protection in demanding maritime conditions.\u003c\/p\u003e","brand":"Lalizas","offers":[{"title":"Default Title","offer_id":50909395124530,"sku":"LAL-71328","price":1565.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/71328_9eeb96fc-4cb0-4902-b5c9-00d7ca5b9d2e.jpg?v=1773944834"},{"product_id":"lal-71327","title":"Lalizas Self Contained Breathing Apparatus Solas\/Med 1,58Gal (6L) 300Bar","description":"\u003cp\u003eEquip your vessel with top-tier emergency protection using the \u003cb\u003eLalizas Self Contained Breathing Apparatus Solas\/Med 1,58Gal (6L) 300Bar\u003c\/b\u003e. This essential SOLAS\/MED approved SCBA provides a critical supply of breathable air, allowing crew members to safely enter smoke-filled compartments or hazardous environments during onboard emergencies like firefighting. Its high-capacity 6L 300Bar cylinder ensures extended usage for vital rescue operations, prioritizing safety on every voyage.\u003c\/p\u003e","brand":"Lalizas","offers":[{"title":"Default Title","offer_id":50909395386674,"sku":"LAL-71327","price":905.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/71327_b90b2471-7c53-4701-b1f6-6aa434caadf1.jpg?v=1773944834"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/collections\/713271_02f81bb8-5311-4713-8eb1-c62561ca66a9.jpg?v=1795788151","url":"https:\/\/www.mauripro.com\/collections\/owners-manuals-lalizas-self-contained-breathing-apparatus.oembed","provider":"MAURIPRO Sailing","version":"1.0","type":"link"}