{"title":"Lewmar 250 \u0026 300 VRTT Retractable Thruster — Owner's Manual","description":"\u003clink rel=\"stylesheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/om-manual-v2.css\"\u003e\u003cstyle\u003e.mpom .om-tbl.nw td+td{white-space:nowrap}.mpom details.om-dd{position:relative;margin:0}.mpom details.om-dd\u003esummary{list-style:none;cursor:pointer}.mpom details.om-dd\u003esummary::-webkit-details-marker{display:none}.mpom .om-dd-menu{position:absolute;left:0;top:calc(100% + 6px);min-width:100%;width:max-content;max-width:360px;background:#fff;border:1px solid #e3e5e8;border-radius:6px;box-shadow:0 8px 24px rgba(0,0,0,.14);z-index:30;padding:6px}.mpom .om-dd-menu a{display:flex;justify-content:space-between;align-items:center;gap:14px;padding:10px 12px;border-radius:4px;font-size:14px;font-weight:600;color:#2a2b2a!important;text-decoration:none!important}.mpom .om-dd-menu a:hover{background:#f5f6f8}.mpom .om-dd-menu small{font-weight:400;color:#5f6368;white-space:nowrap}\u003c\/style\u003e\u003cdiv class=\"mpom\"\u003e\n\u003cdiv class=\"om-head\"\u003e\n\u003cdiv\u003e\n\u003cspan class=\"om-tag\"\u003eOWNER'S MANUAL\u003c\/span\u003e\u003cp class=\"om-lead\"\u003eHull fitting, raise\/lower limit setting, hydraulic and 24 V electric drive data, control box and panel wiring, operation, maintenance and manual raise\/lower for the Lewmar 250 and 300 VRTT retractable thrusters.\u003c\/p\u003e\n\u003cdiv class=\"om-box\"\u003e\n\u003cdiv class=\"om-row\"\u003e\n\u003cspan\u003eDocument\u003c\/span\u003e\u003cb\u003eLewmar 250 \u0026amp; 300 VRTT Retractable Thruster Owner's Manual\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-row\"\u003e\n\u003cspan\u003eFormat\u003c\/span\u003e\u003cb\u003ePDF · 31 pages · 1.5 MB\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-row\" style=\"border-bottom:0\"\u003e\n\u003cspan\u003eLanguage\u003c\/span\u003e\u003cb\u003eEnglish\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-acts\"\u003e\n\u003ca class=\"om-btn dl\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Lewmar-250-300-VRTT-Retractable-Thruster-Owners-Manual.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003csvg viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2.4\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M12 4v11\"\u003e\u003c\/path\u003e\u003cpath d=\"m7 10 5 5 5-5\"\u003e\u003c\/path\u003e\u003cpath d=\"M5 20h14\"\u003e\u003c\/path\u003e\u003c\/svg\u003e Download PDF\u003c\/a\u003e\u003ca class=\"om-btn buy\" href=\"\/products\/lew589028\"\u003eBuy\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-toc\"\u003e\n\u003ca href=\"#om-specs\"\u003eSpecifications\u003c\/a\u003e\u003ca href=\"#om-dims\"\u003eDimensions\u003c\/a\u003e\u003ca href=\"#om-install\"\u003eInstallation\u003c\/a\u003e\u003ca href=\"#om-control\"\u003eControls\u003c\/a\u003e\u003ca href=\"#om-use\"\u003eOperation\u003c\/a\u003e\u003ca href=\"#om-service\"\u003eMaintenance\u003c\/a\u003e\u003ca href=\"#om-products\"\u003eProducts\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-img\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Lewmar-250-300-VRTT-Retractable-Thruster-Owners-Manual-Cover.png\" alt=\"Lewmar 250 \u0026amp; 300 VRTT Retractable Thruster — Owner's Manual\" loading=\"lazy\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-specs\"\u003e\n\u003ch2 class=\"om-h\"\u003eModels \u0026amp; Main Drive\u003c\/h2\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePart no.\u003c\/th\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e59127002\u003c\/td\u003e\n\u003ctd\u003e250 VRTTH (low displacement)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e59127004\u003c\/td\u003e\n\u003ctd\u003e250 VRTTH (high displacement)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e59127100\u003c\/td\u003e\n\u003ctd\u003e250 VRTTE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e59137001\u003c\/td\u003e\n\u003ctd\u003e300 VRTTH (low displacement, aluminium)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e59137002\u003c\/td\u003e\n\u003ctd\u003e300 VRTTH (low displacement, bronze)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e59137003\u003c\/td\u003e\n\u003ctd\u003e300 VRTTH (high displacement, aluminium)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e59137004\u003c\/td\u003e\n\u003ctd\u003e300 VRTTH (high displacement, bronze)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv style=\"height:16px\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"om-grid2\"\u003e\n\u003cdiv\u003e\n\u003ch3 class=\"om-h3\"\u003eHydraulic (VRTTH)\u003c\/h3\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003cth\u003eFlow\u003c\/th\u003e\n\u003cth\u003ePressure (ΔP)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cb\u003e250 VRTT\u003c\/b\u003e – 15 kW output\u003c\/td\u003e\n\u003ctd\u003e16.8 cc\/rev\u003c\/td\u003e\n\u003ctd\u003e53 l\/min\u003c\/td\u003e\n\u003ctd\u003e190 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cb\u003e250 VRTT\u003c\/b\u003e – 15 kW output\u003c\/td\u003e\n\u003ctd\u003e26 cc\/rev\u003c\/td\u003e\n\u003ctd\u003e82 l\/min\u003c\/td\u003e\n\u003ctd\u003e122 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cb\u003e300 VRTT\u003c\/b\u003e – 22.5 kW output\u003c\/td\u003e\n\u003ctd\u003e26 cc\/rev\u003c\/td\u003e\n\u003ctd\u003e72 l\/min\u003c\/td\u003e\n\u003ctd\u003e210 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cb\u003e300 VRTT\u003c\/b\u003e – 22.5 kW output\u003c\/td\u003e\n\u003ctd\u003e30 cc\/rev\u003c\/td\u003e\n\u003ctd\u003e82 l\/min\u003c\/td\u003e\n\u003ctd\u003e182 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eMotor ports: A + B = 3\/4\" BSP, drain = 1\/4\" BSP. The drain line must be connected.\u003c\/li\u003e\n\u003cli\u003eMotors are supplied pre-tested with female ports and blanking caps.\u003c\/li\u003e\n\u003cli\u003eCheck the supply hoses for stray current; if found, fit correctly rated insulated hoses.\u003c\/li\u003e\n\u003cli\u003eOn first start, pulse the controller to fill the hydraulic motor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3 class=\"om-h3\"\u003eElectric (250 VRTTE)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMain and control voltage: 24 VDC.\u003c\/li\u003e\n\u003cli\u003eMinimum voltage at the motor when running: 21 V.\u003c\/li\u003e\n\u003cli\u003eBattery cold crank capacity at least equal to the thruster current.\u003c\/li\u003e\n\u003cli\u003eRing terminals to suit the 10 mm (3\/8\") motor studs; fit the supplied insulating boots (replace them with larger boots if you use very large cables).\u003c\/li\u003e\n\u003cli\u003eTerminal nut torque shown on the drawing: 20 Nm (15 lbs.ft).\u003c\/li\u003e\n\u003cli\u003eBattery switch and correctly sized fuse in the positive line; switch off when nobody is on board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"height:16px\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eCable CSA mm²\u003c\/th\u003e\n\u003cth\u003e35\u003c\/th\u003e\n\u003cth\u003e50\u003c\/th\u003e\n\u003cth\u003e70\u003c\/th\u003e\n\u003cth\u003e95\u003c\/th\u003e\n\u003cth\u003e120\u003c\/th\u003e\n\u003cth\u003e150\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cb\u003eMax total run\u003c\/b\u003e (battery → thruster → battery)\u003c\/td\u003e\n\u003ctd\u003e9 m\u003c\/td\u003e\n\u003ctd\u003e12 m\u003c\/td\u003e\n\u003ctd\u003e21 m\u003c\/td\u003e\n\u003ctd\u003e28 m\u003c\/td\u003e\n\u003ctd\u003e36 m\u003c\/td\u003e\n\u003ctd\u003e45 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eCable AWG\u003c\/th\u003e\n\u003cth\u003e2\u003c\/th\u003e\n\u003cth\u003e1\u003c\/th\u003e\n\u003cth\u003e0\u003c\/th\u003e\n\u003cth\u003e00\u003c\/th\u003e\n\u003cth\u003e000\u003c\/th\u003e\n\u003cth\u003e0000\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMax total run\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e29 ft\u003c\/td\u003e\n\u003ctd\u003e41 ft\u003c\/td\u003e\n\u003ctd\u003e52 ft\u003c\/td\u003e\n\u003ctd\u003e66 ft\u003c\/td\u003e\n\u003ctd\u003e84 ft\u003c\/td\u003e\n\u003ctd\u003e105 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePart no.\u003c\/th\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e589010\u003c\/td\u003e\n\u003ctd\u003eFuse 400A (current 500)\u003c\/td\u003e\n\u003ctd\u003e\u003ca class=\"om-shop\" href=\"\/products\/lewspr589010\"\u003eView part →\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e589006\u003c\/td\u003e\n\u003ctd\u003eFuse holder\u003c\/td\u003e\n\u003ctd\u003e\u003ca class=\"om-ask\" href=\"\/pages\/contact\"\u003eAsk us to source it →\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp class=\"om-note\"\u003eLeave enough slack in the power cables, supported, for the vertical travel of the thruster. Electric motors spark and run hot: keep them away from flammable or sealed areas.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-dims\"\u003e\n\u003ch2 class=\"om-h\"\u003eDimensions \u0026amp; Stroke\u003c\/h2\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eModel no.\u003c\/th\u003e\n\u003cth\u003eDim 'A' (max height, mm)\u003c\/th\u003e\n\u003cth\u003eStroke (mm)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e59127002\u003c\/td\u003e\n\u003ctd\u003e721\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e59127004\u003c\/td\u003e\n\u003ctd\u003e711\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e59127100\u003c\/td\u003e\n\u003ctd\u003e886\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e59137001\u003c\/td\u003e\n\u003ctd\u003e765\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e59137002\u003c\/td\u003e\n\u003ctd\u003e765\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e59137003\u003c\/td\u003e\n\u003ctd\u003e751\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e59137004\u003c\/td\u003e\n\u003ctd\u003e751\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eBase plate pre-drilled with 8.5 mm holes (250 VRTT) or 10.5 mm holes (300 VRTT) (as printed: \"10.5 holes\").\u003c\/li\u003e\n\u003cli\u003eThe drawings show the hydraulic version.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block om-grid2\" id=\"om-install\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003ePlacement \u0026amp; Hull Fitting\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFit as far forward as possible. With the leg lowered, the hub centre line must be at least 1.5 × propeller diameter below the waterline and clear of the hull.\u003c\/li\u003e\n\u003cli\u003eLift with proper strops; never by the lead screw assembly or the propeller shroud. Protect the micro switches, control box and the seating surfaces.\u003c\/li\u003e\n\u003cli\u003eBuild a watertight compartment over the hull opening; its top is the seat for the base plate and must carry the thruster weight, the thrust and the loads at sea (naval architect recommended).\u003c\/li\u003e\n\u003cli\u003eAllow approx. 5–10 mm (3\/16–3\/8\") all-round clearance between the box and the shroud.\u003c\/li\u003e\n\u003cli\u003eBed the base plate on a thin closed-cell neoprene gasket or sealing compound; stainless bolts property class 70 with nuts, plain and locking washers. In an aluminium hull the base plate (5083-T6) may be welded to the box.\u003c\/li\u003e\n\u003cli\u003eRe-use the hull cut-out as the closing plate, fixed to the ribs on the tunnel shroud. The raise\/lower motor handles a hull piece up to 50 kg (110 lbs). Bolt heads must not foul the propeller tips.\u003c\/li\u003e\n\u003cli\u003eMould a landing\/register into the hull opening so the closing plate locates when retracted, with a resilient gasket that will not stick.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eLimits \u0026amp; Painting\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThe unit ships with the leg raised. Lower it (power or the lead screw) to fit the hull fairing.\u003c\/li\u003e\n\u003cli\u003eLimit switches are factory set and need adjusting at installation: set the adjustable stops with a 13 mm spanner, without crushing the plastic stop; Loctite 243 on the nuts at final setting.\u003c\/li\u003e\n\u003cli\u003eMake sure the limit switch actually \"makes\" at full retraction and full deployment, or the raise\/lower motor stays powered and loads the shroud\/closing plate.\u003c\/li\u003e\n\u003cli\u003eWhen lowered, the top plate must not touch the top face of the lower housing.\u003c\/li\u003e\n\u003cli\u003eBase plate is supplied bare aluminium: prime and antifoul its underside. Hub and propeller may be antifouled; the gel-coated shroud usually needs nothing.\u003c\/li\u003e\n\u003cli\u003eNever paint the 6 anodes (2 on the propeller shafts, 4 on the base plate) or the stainless main leg.\u003c\/li\u003e\n\u003cli\u003eBars or grids over the tunnel affect performance and must be removable for maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-control\"\u003e\n\u003ch2 class=\"om-h\"\u003eControl Box \u0026amp; Panel\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThe raise\/lower control box comes pre-wired to the limit switches, the raise\/lower motor and (VRTTE) the main drive control, with a mounting bracket and long leads.\u003c\/li\u003e\n\u003cli\u003eControl box supply: 24 VDC, 5 A nominal, from a separate source to the VRTTE main drive; it must handle a motor inrush of 45 A for 10 mS.\u003c\/li\u003e\n\u003cli\u003eThe box circuit breaker trips if the raise\/lower mechanism meets an obstruction.\u003c\/li\u003e\n\u003cli\u003eThe box only controls raise\/lower, not the main hydraulic or electric drive.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003ePower supply to raise\/lower control switches \u0026amp; lamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eSwitched (latched) power in, enables raise\/lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eSwitched (momentary) signal in: raise\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eSwitched (momentary) signal in: lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e0V supply to raise\/lower control switches \u0026amp; lamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6 \u0026amp; 7\u003c\/td\u003e\n\u003ctd\u003eVolt-free contact (5A max), closed when the thruster is UP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8 \u0026amp; 9\u003c\/td\u003e\n\u003ctd\u003eVolt-free contact (5A max), closed when the thruster is DOWN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 \u0026amp; 11\u003c\/td\u003e\n\u003ctd\u003eVolt-free contact (5A max), closed when the thruster is DOWN; not available on VRTTE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv style=\"height:16px\"\u003e\u003c\/div\u003e\n\u003cp\u003eVRTT control panel, part number 58401038 (ordered separately): 100 mm × 85 mm, IP67 above the panel with a suitable gasket or sealant. Loom 1 goes to the VRTT control box; Loom 2 goes to the VRTTE main drive control (black box) or to the hydraulic valves.\u003c\/p\u003e\n\u003cdiv class=\"om-grid2\"\u003e\n\u003cdiv\u003e\n\u003ch3 class=\"om-h3\"\u003eLoom 1 (control box)\u003c\/h3\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eWire\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eBox terminal\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eYellow\u003c\/td\u003e\n\u003ctd\u003eRaise switch position indicator\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003ctd\u003eLower switch position indicator\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrown\u003c\/td\u003e\n\u003ctd\u003eOn\/Off switch \/ control enable\u003c\/td\u003e\n\u003ctd\u003e2 \u0026amp; 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003ctd\u003e+V panel supply\u003c\/td\u003e\n\u003ctd\u003e1 \u0026amp; 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003ctd\u003e0V indicator common\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrey\u003c\/td\u003e\n\u003ctd\u003eLower switch signal\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrange\u003c\/td\u003e\n\u003ctd\u003eRaise switch signal\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3 class=\"om-h3\"\u003eLoom 2 (main drive)\u003c\/h3\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eWire\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eConnector pin\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003ctd\u003eJoystick switch common\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrey\u003c\/td\u003e\n\u003ctd\u003eThrust to PORT signal\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003ctd\u003eThrust to STBD signal\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eVRTTE: the panel connects to the main drive black box with standard Lewmar TT control looms (below). Extra wiring disables the main drive when the leg is not lowered.\u003c\/li\u003e\n\u003cli\u003eVRTTH: the panel joystick can switch the valves (discard the loom 1 connector). Power the valve circuit from a separate fuse, wire the second thruster-down volt-free contact into it, and add a hydraulic reservoir level switch. Contacts are rated 5A.\u003c\/li\u003e\n\u003cli\u003eWithout the VRTT panel: raise and lower switches must be momentary, the on\/off switch latching.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePart no.\u003c\/th\u003e\n\u003cth\u003eControl cable length\u003c\/th\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e589015\u003c\/td\u003e\n\u003ctd\u003e2M\u003c\/td\u003e\n\u003ctd\u003e\u003ca class=\"om-shop\" href=\"\/products\/lew589015\"\u003eView part →\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e589016\u003c\/td\u003e\n\u003ctd\u003e7M\u003c\/td\u003e\n\u003ctd\u003e\u003ca class=\"om-shop\" href=\"\/products\/lew589016\"\u003eView part →\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e589017\u003c\/td\u003e\n\u003ctd\u003e10M\u003c\/td\u003e\n\u003ctd\u003e\u003ca class=\"om-shop\" href=\"\/products\/lew589017\"\u003eView part →\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e589018\u003c\/td\u003e\n\u003ctd\u003e14M\u003c\/td\u003e\n\u003ctd\u003e\u003ca class=\"om-shop\" href=\"\/products\/lew589018\"\u003eView part →\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e589019\u003c\/td\u003e\n\u003ctd\u003e18M\u003c\/td\u003e\n\u003ctd\u003e\u003ca class=\"om-shop\" href=\"\/products\/lew589019\"\u003eView part →\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e589020\u003c\/td\u003e\n\u003ctd\u003e22M\u003c\/td\u003e\n\u003ctd\u003e\u003ca class=\"om-shop\" href=\"\/products\/lew589020\"\u003eView part →\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-use\"\u003e\n\u003ch2 class=\"om-h\"\u003eOperation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eSystem On\/Off\u003c\/b\u003e (latching, red lamp): enables the control box; the raise\/lower lamps show the leg position. Switching off halts the leg even mid-stroke.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRaise\u003c\/b\u003e (momentary): a brief push retracts the leg fully; blue lamp when fully retracted.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eLower\u003c\/b\u003e (momentary): a brief push deploys the leg fully; blue lamp when fully lowered. The thrust joystick\/switches only work once fully lowered.\u003c\/li\u003e\n\u003cli\u003eThe down lamp stays lit even with the system off: always raise the thruster when not in use.\u003c\/li\u003e\n\u003cli\u003eSystem lamp on but neither position lamp lit: the leg stopped mid-stroke (switched off too early or obstruction). Check for obstructions, then press UP to park it.\u003c\/li\u003e\n\u003cli\u003eControl box breaker tripped: clear the obstruction, then push the trip button back in.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"om-note\"\u003eDo not run the thruster out of the water, even for a few seconds: the motor overspeeds by 300%. With the leg down keep boat speed below 2 knots. Do not use the thruster near swimmers or as an earth point.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block om-grid2\" id=\"om-service\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003ePeriodic Maintenance\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eGeneral:\u003c\/b\u003e lower and raise regularly to stop the leg seizing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e6 months:\u003c\/b\u003e clean oil\/grease and dirt off the mechanism; wipe the lead screw, light coat of oil; grease the guide bars; replace anodes at more than 50% decay (all together).\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e12 months:\u003c\/b\u003e grease the main bearing nipple; check motor terminal tightness (250VRTTE); re-torque nuts and bolts; check propellers; clean leg and shroud; check the shroud for cracks; brush and vacuum carbon dust from the brush gear (250 VRTTE).\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e24–36 months:\u003c\/b\u003e check the lead screw and manual override bolt for wear; check the motor brushes (raise\/lower motor on all units, main motor on 250VRTTE).\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eLaid up ashore:\u003c\/b\u003e hose the hub and leg with fresh water, grease the leg and fully retract.\u003c\/li\u003e\n\u003cli\u003eThe hub is sealed and needs no routine maintenance. Service the hydraulic system to its maker's instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eAnodes \u0026amp; Manual Raise\/Lower\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e6 anodes: 2 on the propeller shaft, 4 on the base plate. Inspect monthly for the first six months, every three months from six months to one year, then every six months.\u003c\/li\u003e\n\u003cli\u003eFast anode decay after commissioning points to earth leaks or electrical faults: have the boat checked. Check the aluminium mounting plate regularly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eManual raise\/lower\u003c\/b\u003e (isolate power first): remove the 6 mm cross bolt from the raise\/lower drive (8 mm spanner and 3 mm hex key; do not over-tighten on refit).\u003c\/li\u003e\n\u003cli\u003eTurn the top of the lead screw with a 17 mm spanner or socket: clockwise to raise, anti-clockwise to lower. Do not hit the limit switches at the ends of the stroke.\u003c\/li\u003e\n\u003cli\u003eThe leg lowers under its own weight; extra force on top may be needed to overcome stiction.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"om-note\"\u003eNeed a part that isn't listed? \u003ca href=\"\/pages\/contact\"\u003eAsk us to source it\u003c\/a\u003e and quote the part number from the PDF.\u003c\/p\u003e\n\u003ch2 class=\"om-h\" id=\"om-products\"\u003eProducts in this Manual\u003c\/h2\u003e\n\u003c\/div\u003e","products":[{"product_id":"lewspr589010","title":"Lewmar Bow Thruster Fuse 400 Amp","description":"\u003cp\u003eShop your Lewmar Spare Parts at Mauri Pro Sailing Store, where we think about what makes boaters lives easierand bring those ideas to life in our products. We aim to relieve the aching muscles that often come with anchoring and give you more confidence when docking. That' why each Lewmar Sailing Hardware product we bring to the market is chosen by its finest quality materials and engineered for excellence.\u003c\/p\u003e\u003cp\u003eOur Part # LEWSPR589010 | Lewmar Part # 589010\u003c\/p\u003e","brand":"Lewmar","offers":[{"title":"Default Title","offer_id":49348011819314,"sku":"LEWSPR589010","price":33.34,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/LEWSPR589010.jpg?v=1728020933"},{"product_id":"lew589019","title":"Lewmar 18M Control Cable \u0026 Connectors","description":"\u003cp\u003eAchieve precise and responsive control on your vessel with the \u003cb\u003eLewmar 18M Control Cable \u0026amp; Connectors\u003c\/b\u003e. This durable 18-meter cable assembly provides a smooth and reliable link between your helm controls and engine or gearbox, ensuring effortless throttle and gear changes. Upgrade or replace your marine control cables for enhanced peace of mind and performance.\u003c\/p\u003e","brand":"Lewmar","offers":[{"title":"Default Title","offer_id":50904383422770,"sku":"LEW589019","price":83.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Lewmar-Spare_b1bf4faf-ffe0-4cc2-bda3-dc3486eaa941.png?v=1770771019"},{"product_id":"lew589017","title":"Lewmar 10M Control Cable \u0026 Connectors","description":"\u003cp\u003eGain precise and reliable remote operation for your marine equipment with the \u003cb\u003eLewmar 10M Control Cable \u0026amp; Connectors\u003c\/b\u003e. This durable 10-meter cable provides ample length for flexible installation, ensuring seamless communication between your control panel and windlass or thruster. Complete with essential connectors, it makes setup straightforward for consistent and responsive control.\u003c\/p\u003e","brand":"Lewmar","offers":[{"title":"Default Title","offer_id":50904383455538,"sku":"LEW589017","price":59.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Lewmar-Spare_92ad9786-4f1f-4220-8616-17c5ba6b5176.png?v=1770771019"},{"product_id":"lew589015","title":"Lewmar 2M Control Cable Extension","description":"\u003cp\u003eGain greater flexibility in your boat's control system with the convenient \u003cb\u003eLewmar 2M Control Cable Extension\u003c\/b\u003e. This extension allows you to strategically place your helm or control panel, providing an additional two meters of reach for seamless integration with your existing Lewmar setup. Perfect for custom installations or optimizing the ergonomics of your cockpit or flybridge.\u003c\/p\u003e","brand":"Lewmar","offers":[{"title":"Default Title","offer_id":50904383488306,"sku":"LEW589015","price":34.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Lewmar-Spare_e988a62f-262e-4d8a-8be3-b5a7d5b84b21.png?v=1770771020"},{"product_id":"lew589018","title":"Lewmar 14M Control Cable \u0026 Connectors","description":"\u003cp\u003eAchieve precise and reliable control over your marine systems with the \u003cb\u003eLewmar 14M Control Cable \u0026amp; Connectors\u003c\/b\u003e. This robust 14-meter cable provides the perfect length for a wide range of vessel layouts, ensuring smooth and responsive operation for your steering, throttle, or other remote functions. Engineered for durability and easy installation, it delivers consistent performance on the water.\u003c\/p\u003e","brand":"Lewmar","offers":[{"title":"Default Title","offer_id":50904383652146,"sku":"LEW589018","price":72.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Lewmar-Spare_ad4d8b1d-6ef6-40f3-9d0f-e60552391d1f.png?v=1770771020"},{"product_id":"lew589016","title":"Lewmar 7M Control Cable  \u0026 Connectors","description":"\u003cp\u003eEnsure precise and reliable control over your marine systems with the \u003cb\u003eLewmar 7M Control Cable \u0026amp; Connectors\u003c\/b\u003e. This durable, high-quality cable provides seamless operation for steering, throttle, or engine controls, enhancing your boating experience. Pre-fitted with robust connectors, installation is straightforward, guaranteeing a secure and long-lasting connection in any marine environment.\u003c\/p\u003e","brand":"Lewmar","offers":[{"title":"Default Title","offer_id":50904383881522,"sku":"LEW589016","price":50.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Lewmar-Spare_1cfc993f-af63-4993-8407-4577c0d6b69a.png?v=1770771020"},{"product_id":"lew589057","title":"Lewmar Vrtt Anode Kit","description":"\u003cp\u003eProtect your vital Lewmar thruster from corrosive elements with the essential \u003cb\u003eLewmar Vrtt Anode Kit\u003c\/b\u003e. This sacrificial anode kit is crucial for preventing electrolysis, extending the lifespan of your thruster components and ensuring peak performance in saltwater conditions.\u003c\/p\u003e","brand":"Lewmar","offers":[{"title":"Default Title","offer_id":50904384078130,"sku":"LEW589057","price":94.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Lewmar-Spare_d4e344a7-e7de-4d49-8d52-0c77a821745d.png?v=1770771020"},{"product_id":"lew589020","title":"Lewmar 22M Control Cable \u0026 Connectors","description":"\u003cp\u003eAchieve precise and reliable control over long distances with the \u003cb\u003eLewmar 22M Control Cable \u0026amp; Connectors\u003c\/b\u003e. This durable marine control cable, complete with connectors, provides smooth throttle or steering responses, making it perfect for various yachting and boat control applications. Its generous 22-meter length ensures flexible installation options for your vessel's remote systems.\u003c\/p\u003e","brand":"Lewmar","offers":[{"title":"Default Title","offer_id":50904384667954,"sku":"LEW589020","price":102.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Lewmar-Spare_662197bc-87b2-4e66-8138-3c88561a5c81.png?v=1770771021"},{"product_id":"lew589028","title":"Lewmar 250\/300 Vrtt Control Box","description":"\u003cp\u003eExperience unparalleled control and precise maneuvering with the advanced \u003cb\u003eLewmar 250\/300 Vrtt Control Box\u003c\/b\u003e. This essential control unit provides seamless variable-speed operation for your Lewmar VRTT thruster, allowing you to dock and navigate with exceptional accuracy and confidence. Upgrade or replace your control box to optimize your thruster system's performance for safer and easier boat handling.\u003c\/p\u003e","brand":"Lewmar","offers":[{"title":"Default Title","offer_id":50904384831794,"sku":"LEW589028","price":567.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Lewmar-Spare_4c3d949a-0bc8-47ad-8bce-6e5ae4a1ac44.png?v=1770771022"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/collections\/Lewmar-250-300-VRTT-Retractable-Thruster-Owners-Manual-Cover.png?v=1791467930","url":"https:\/\/www.mauripro.com\/collections\/owners-manuals-lewmar-250-300-vrtt-retractable-thruster.oembed","provider":"MAURIPRO Sailing","version":"1.0","type":"link"}