{"title":"Quick BK Series Water Heaters — Installation \u0026 Use Manual","description":"\u003clink rel=\"stylesheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/om-manual-v2.css\"\u003e\u003cstyle\u003e.mpom .om-tbl.nw td+td{white-space:nowrap}.mpom details.om-dd{position:relative;margin:0}.mpom details.om-dd\u003esummary{list-style:none;cursor:pointer}.mpom details.om-dd\u003esummary::-webkit-details-marker{display:none}.mpom .om-dd-menu{position:absolute;left:0;top:calc(100% + 6px);min-width:100%;width:max-content;max-width:360px;background:#fff;border:1px solid #e3e5e8;border-radius:6px;box-shadow:0 8px 24px rgba(0,0,0,.14);z-index:30;padding:6px}.mpom .om-dd-menu a{display:flex;justify-content:space-between;align-items:center;gap:14px;padding:10px 12px;border-radius:4px;font-size:14px;font-weight:600;color:#2a2b2a!important;text-decoration:none!important}.mpom .om-dd-menu a:hover{background:#f5f6f8}.mpom .om-dd-menu small{font-weight:400;color:#5f6368;white-space:nowrap}\u003c\/style\u003e\u003cdiv class=\"mpom\"\u003e\n\u003cdiv class=\"om-head\"\u003e\n\u003cdiv\u003e\n\u003cspan class=\"om-tag\"\u003eINSTALLATION MANUAL\u003c\/span\u003e\u003cp class=\"om-lead\"\u003eTechnical data, installation, single- and three-phase connection, thermostat setting and reset, maintenance and dimensions for the Quick BK Series large water heaters with double electric element (BK2 160, BK2 200, BK3 200).\u003c\/p\u003e\n\u003cdiv class=\"om-box\"\u003e\n\u003cdiv class=\"om-row\"\u003e\n\u003cspan\u003eDocument\u003c\/span\u003e\u003cb\u003eQuick BK Series Water Heaters Installation \u0026amp; Use Manual\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-row\"\u003e\n\u003cspan\u003eFormat\u003c\/span\u003e\u003cb\u003ePDF · 16 pages · 1.1 MB\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-row\" style=\"border-bottom:0\"\u003e\n\u003cspan\u003eLanguage\u003c\/span\u003e\u003cb\u003eEnglish\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-acts\"\u003e\n\u003ca class=\"om-btn dl\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Quick-BK-Series-Water-Heaters-Installation-Use-Manual.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003csvg viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2.4\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M12 4v11\"\u003e\u003c\/path\u003e\u003cpath d=\"m7 10 5 5 5-5\"\u003e\u003c\/path\u003e\u003cpath d=\"M5 20h14\"\u003e\u003c\/path\u003e\u003c\/svg\u003e Download PDF\u003c\/a\u003e\u003ca class=\"om-btn buy\" href=\"\/collections\/quick-plumbing-water-heaters\"\u003eView Collection\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-toc\"\u003e\n\u003ca href=\"#om-specs\"\u003eTechnical Data\u003c\/a\u003e\u003ca href=\"#om-install\"\u003eInstallation\u003c\/a\u003e\u003ca href=\"#om-electrical\"\u003eElectrical\u003c\/a\u003e\u003ca href=\"#om-maint\"\u003eMaintenance\u003c\/a\u003e\u003ca href=\"#om-products\"\u003eProducts\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-img\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Quick-BK-Series-Water-Heaters-Installation-Use-Manual-Cover.png\" alt=\"Quick BK Series Water Heaters — Installation \u0026amp; Use Manual\" loading=\"lazy\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-specs\"\u003e\n\u003ch2 class=\"om-h\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cp\u003eAISI 316L tank, polyurethane foam insulation, grey skai cladding, double electric element with adjustable and safety thermostat, relief\/non-return valve. Heat exchanger on BK2 only.\u003c\/p\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eBK2 160\u003c\/th\u003e\n\u003cth\u003eBK2 200\u003c\/th\u003e\n\u003cth\u003eBK3 200\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e160 l (42.27 US gal)\u003c\/td\u003e\n\u003ctd\u003e200 l (52.84 US gal)\u003c\/td\u003e\n\u003ctd\u003e200 l (52.84 US gal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (empty)\u003c\/td\u003e\n\u003ctd\u003e44 kg (97 lb)\u003c\/td\u003e\n\u003ctd\u003e52 kg (114 lb)\u003c\/td\u003e\n\u003ctd\u003e53 kg (116 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat exchanger\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv style=\"height:16px\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectric element voltage\u003c\/td\u003e\n\u003ctd\u003e230 Vac ± 10% - 400 Vac ± 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectric element power\u003c\/td\u003e\n\u003ctd\u003e2 × 2 KW (model 02) or 2 × 4 KW (model 04)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest pressure\u003c\/td\u003e\n\u003ctd\u003e800 kPa (1 Bar = 100 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum working pressure\u003c\/td\u003e\n\u003ctd\u003e1000 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFittings\u003c\/td\u003e\n\u003ctd\u003e3\/4\" (1\" exchanger)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp class=\"om-note\"\u003eModel code: series, tank capacity (l), heat exchanger (BK2 only), double element (D), element power (KW), element voltage on BK2: three-phase (T) or single-phase (-).\u003c\/p\u003e\n\u003ch3\u003eIn the Box\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003eWater heater, floor or wall-mounting brackets (optional for BK2, integrated on BK3), screws and hardware, user's manual, conditions of warranty.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-install\"\u003e\n\u003ch2 class=\"om-h\"\u003eInstallation and First Use\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDry, well-ventilated place: poor ventilation causes condensation that can look like a leak.\u003c\/li\u003e\n\u003cli\u003eSize the mounting for the full weight: empty weight plus about 1 kg (2.2 lb) per litre of water.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003col\u003e\n\u003cli\u003eFit the brackets and fix the heater to a flat surface with supports suited to the weight and surface.\u003c\/li\u003e\n\u003cli\u003eConnect tap cold water in, hot water out and (BK2) the engine cooling circuit to the exchanger, keeping that run as short as possible. On the BK3 one hot-water outlet is for vertical position only.\u003c\/li\u003e\n\u003cli\u003eUse Loctite 243, 577 or Teflon on the fittings and check for leaks.\u003c\/li\u003e\n\u003cli\u003eFit the relief valve stub pipe with its clamp, on a continuous downward slope, protected from ice and left open.\u003c\/li\u003e\n\u003cli\u003eOpen the hot taps and run the pump to purge air; close them when only water flows.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-electrical\"\u003e\n\u003ch2 class=\"om-h\"\u003ePower Supply and Thermostat\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNever switch on the element unless the heater is full of water.\u003c\/li\u003e\n\u003cli\u003eFit a double pole switch and a fuse suited to the input; at least 3 mm insulation between contacts; follow national wiring standards. Check the supply voltage matches.\u003c\/li\u003e\n\u003cli\u003eWiring diagrams in the PDF: single-phase 2000 watt connection and three-phase 4000 watt connection.\u003c\/li\u003e\n\u003cli\u003eThermostat (electric element only): factory-set to 60°C. Single-phase: power off, remove the protection cover, set the knob with a screwdriver, refit, power on. Three-phase: turn the knob to the desired value.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-maint\"\u003e\n\u003ch2 class=\"om-h\"\u003eMaintenance\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCheck the magnesium anode every 12 months and replace it if deteriorated.\u003c\/li\u003e\n\u003cli\u003eDrain the heater with the valve lever when unused in the cold season.\u003c\/li\u003e\n\u003cli\u003ePeriodically check fittings for leaks, fastening screws for wear or corrosion, and the electrical system.\u003c\/li\u003e\n\u003cli\u003eOver-temperature reset, single-phase: power off, remove the cover, turn the knob to maximum, press the reset button on the double thermostat, set the temperature, refit and power on. The three-phase thermostat has its own manual reset device.\u003c\/li\u003e\n\u003cli\u003eIf the safety device trips repeatedly, or the power cable is damaged, contact a Quick service centre.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp class=\"om-note\"\u003eNeed a part that isn't listed? \u003ca href=\"\/pages\/contact\"\u003eAsk us to source it\u003c\/a\u003e and quote the part number from the PDF.\u003c\/p\u003e\n\u003ch2 class=\"om-h\" id=\"om-products\"\u003eProducts in this Manual\u003c\/h2\u003e\n\u003c\/div\u003e","products":[{"product_id":"qckflbk201602s0a00","title":"Quick Nautic Boiler BK2 160L \/ 42.3 Gallon (Stainless Steel) - 230V - 2000W","description":"\u003cp\u003eThe heat exchanger used for Quick “Nautic Boiler BK” is AISI 316 stainless steel. The heat exchange capacity is notably higher than that achieved from other manufacturers.\u003c\/p\u003e\u003cp\u003eThe tank is made in AISI 316 stainless steel welded with Argon shielding gas and hence highly resistant to corrosive agents.\u003c\/p\u003e\u003cp\u003eThe electrical heating element is made of Incoloy®\u003c\/p\u003e\u003cp\u003eThe thermal insulation is high thickness polyurethane foam injected between the cover and tank giving excellent heat retention properties.\u003c\/p\u003e\u003cp\u003eOur Part # QCKFLBK201602S0A00 | Mfr. Part # FLBK201602S0A00\u003c\/p\u003e","brand":"Quick","offers":[{"title":"Default Title","offer_id":49349158469938,"sku":"QCKFLBK201602S0A00","price":2363.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/QCKFLBK201602S0A00.jpg?v=1728051058"},{"product_id":"qckflbk202002s0a00","title":"Quick Nautic Boiler BK2 200L \/ 52.8 Gallon (Stainless Steel) - 230V - 2000W","description":"\u003cp\u003eThe heat exchanger used for Quick “Nautic Boiler BK” is AISI 316 stainless steel. The heat exchange capacity is notably higher than that achieved from other manufacturers.\u003c\/p\u003e\u003cp\u003eThe tank is made in AISI 316 stainless steel welded with Argon shielding gas and hence highly resistant to corrosive agents.\u003c\/p\u003e\u003cp\u003eThe electrical heating element is made of Incoloy®\u003c\/p\u003e\u003cp\u003eThe thermal insulation is high thickness polyurethane foam injected between the cover and tank giving excellent heat retention properties.\u003c\/p\u003e\u003cp\u003eOur Part # QCKFLBK202002S0A00 | Mfr. Part # FLBK202002S0A00\u003c\/p\u003e","brand":"Quick","offers":[{"title":"Default Title","offer_id":49349168202034,"sku":"QCKFLBK202002S0A00","price":2684.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/QCKFLBK202002S0A00.jpg?v=1728030393"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/collections\/Quick-BK-Series-Water-Heaters-Installation-Use-Manual-Cover.png?v=1792719829","url":"https:\/\/www.mauripro.com\/collections\/owners-manuals-quick-bk-series-water-heater.oembed","provider":"MAURIPRO Sailing","version":"1.0","type":"link"}