{"title":"Quick PCS System — User Manual \u0026 Installation Guides","description":"\u003clink rel=\"stylesheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/om-manual-v2.css\"\u003e\u003cstyle\u003e.mpom .om-tbl.nw td+td{white-space:nowrap}.mpom details.om-dd{position:relative;margin:0}.mpom details.om-dd\u003esummary{list-style:none;cursor:pointer}.mpom details.om-dd\u003esummary::-webkit-details-marker{display:none}.mpom .om-dd-menu{position:absolute;left:0;top:calc(100% + 6px);min-width:100%;width:max-content;max-width:360px;background:#fff;border:1px solid #e3e5e8;border-radius:6px;box-shadow:0 8px 24px rgba(0,0,0,.14);z-index:30;padding:6px}.mpom .om-dd-menu a{display:flex;justify-content:space-between;align-items:center;gap:14px;padding:10px 12px;border-radius:4px;font-size:14px;font-weight:600;color:#2a2b2a!important;text-decoration:none!important}.mpom .om-dd-menu a:hover{background:#f5f6f8}.mpom .om-dd-menu small{font-weight:400;color:#5f6368;white-space:nowrap}\u003c\/style\u003e\u003cdiv class=\"mpom\"\u003e\n\u003cdiv class=\"om-head\"\u003e\n\u003cdiv\u003e\n\u003cspan class=\"om-tag\"\u003eINSTALLATION MANUAL\u003c\/span\u003e\u003cp class=\"om-lead\"\u003eThe Quick PCS (Proportional Control System) for thrusters and windlasses: which modules make up a system, how to lay out the CAN bus backbone, first configuration from the DTW display, daily use of the levers and HOLD, the menus, troubleshooting, and the installation guides for every module.\u003c\/p\u003e\n\u003cdiv class=\"om-box\"\u003e\n\u003cdiv class=\"om-row\"\u003e\n\u003cspan\u003eDocument\u003c\/span\u003e\u003cb\u003eQuick PCS System User Manual \u0026amp; Installation Guides\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-row\"\u003e\n\u003cspan\u003eFormat\u003c\/span\u003e\u003cb\u003ePDF · 64 pages · 2.3 MB\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-row\" style=\"border-bottom:0\"\u003e\n\u003cspan\u003eLanguage\u003c\/span\u003e\u003cb\u003eEnglish\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-acts\"\u003e\u003cdetails class=\"om-dd\"\u003e\u003csummary class=\"om-btn dl\"\u003e\u003csvg viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2.4\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M12 4v11\"\u003e\u003c\/path\u003e\u003cpath d=\"m7 10 5 5 5-5\"\u003e\u003c\/path\u003e\u003cpath d=\"M5 20h14\"\u003e\u003c\/path\u003e\u003c\/svg\u003e Download PDF ▾\u003c\/summary\u003e\u003cdiv class=\"om-dd-menu\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Quick-PCS-Proportional-Control-System-User-Manual.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003eInstallation Manual\u003c\/span\u003e\u003csmall\u003ePDF · 64 p.\u003c\/small\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Quick-PCS-TJ-WJ-Controls-Installation-Manual.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003ePCS TJ \/ WJ controls installation\u003c\/span\u003e\u003csmall\u003ePDF · 36 p.\u003c\/small\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Quick-PCS-SVJB-Junction-Box-Installation-Manual.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003ePCS SVJB junction box installation\u003c\/span\u003e\u003csmall\u003ePDF · 36 p.\u003c\/small\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Quick-PCS-SRV-Server-Unit-Installation-Manual.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003ePCS SRV server unit installation\u003c\/span\u003e\u003csmall\u003ePDF · 24 p.\u003c\/small\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Quick-PCS-NCG-T-NCG-W-Interface-Installation-Manual.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003ePCS NCG-T \/ NCG-W interface installation\u003c\/span\u003e\u003csmall\u003ePDF · 36 p.\u003c\/small\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Quick-PCS-NCG-T-B01-Mercury-Supplement.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003ePCS NCG-T B01 for Mercury controls (supplement)\u003c\/span\u003e\u003csmall\u003ePDF · 12 p.\u003c\/small\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Quick-PCS-NCG-T-C02-Volvo-Penta-Supplement.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003ePCS NCG-T C02 for Volvo Penta controls (supplement)\u003c\/span\u003e\u003csmall\u003ePDF · 20 p.\u003c\/small\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Quick-PCS-MCI-A-MCI-B-Interface-Installation-Manual.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003ePCS MCI-A \/ MCI-B interface installation\u003c\/span\u003e\u003csmall\u003ePDF · 36 p.\u003c\/small\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Quick-PCS-GTW-A-GTW-B-Interface-Installation-Manual.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003ePCS GTW-A \/ GTW-B interface installation\u003c\/span\u003e\u003csmall\u003ePDF · 36 p.\u003c\/small\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Quick-PCS-DTW-DTWF-Display-Installation-Manual.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003ePCS DTW \/ DTWF display installation\u003c\/span\u003e\u003csmall\u003ePDF · 36 p.\u003c\/small\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-toc\"\u003e\n\u003ca href=\"#om-system\"\u003eModules\u003c\/a\u003e\u003ca href=\"#om-backbone\"\u003eBackbone\u003c\/a\u003e\u003ca href=\"#om-specs\"\u003eModule Data\u003c\/a\u003e\u003ca href=\"#om-config\"\u003eConfiguration\u003c\/a\u003e\u003ca href=\"#om-operation\"\u003eOperation\u003c\/a\u003e\u003ca href=\"#om-trouble\"\u003eTroubleshooting\u003c\/a\u003e\u003ca href=\"#om-products\"\u003eProducts\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-img\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Quick-PCS-Proportional-Control-System-User-Manual-Cover.png\" alt=\"Quick PCS System — User Manual \u0026amp; Installation Guides\" loading=\"lazy\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-system\"\u003e\n\u003ch2 class=\"om-h\"\u003eSystem \u0026amp; Modules\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModular system on a CAN bus backbone controlling up to two bow thrusters, two stern thrusters and two windlasses.\u003c\/li\u003e\n\u003cli\u003eMinimum system: one server module, one display module, one interface module and one control module. Connect only genuine Quick PCS products; driving the PCS directly without a PCS NCG module voids the warranty of every PCS product on the network.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"height:16px\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eModule\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCS SRV\u003c\/td\u003e\n\u003ctd\u003eServer: detects all modules at switch-on and manages control\/interface traffic. Only one per system; its USB flash drive must stay plugged in (firmware updates, log.txt).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCS DTW \/ PCS DTWF\u003c\/td\u003e\n\u003ctd\u003eDisplay (DTWF recessed): first configuration, actuator data, personal settings, errors. At least one per system.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCS TJ1 \/ TJ1F\u003c\/td\u003e\n\u003ctd\u003eSingle thruster control (one or two bow thrusters).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCS TJ2 \/ TJ2F\u003c\/td\u003e\n\u003ctd\u003eDual thruster control (bow and stern).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCS WJ1 \/ WJ1F – WJ2 \/ WJ2F\u003c\/td\u003e\n\u003ctd\u003eSingle \/ dual (left and right) windlass control. F = recessed (flush).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCS GTW-A\u003c\/td\u003e\n\u003ctd\u003eInterface for AC actuators (frequency inverter, GDC A030 cable to the drive's CANopen RJ45 port, RJ45 terminator supplied).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCS GTW-B\u003c\/td\u003e\n\u003ctd\u003eInterface for DC actuators (GDC B030 cable to the CAN connector of the Quick MSC drive).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCS MCI-A\u003c\/td\u003e\n\u003ctd\u003eInterface for hydraulic actuators, with the PCS SVJB junction box (to the solenoid valves) and PCS TSB (reservoir sensors).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCS MCI-B\u003c\/td\u003e\n\u003ctd\u003eInterface for DC-AC or QSY extra-low-voltage actuators (MDC B030 cable to the 35P connector of the DC-AC drive).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCS NCG-T \/ NCG-W\u003c\/td\u003e\n\u003ctd\u003eGateways that let OEM control systems drive and monitor the thrusters \/ windlasses. PCS control modules are still required for direct control in an emergency.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCS CHC \/ PCS MCI-CHC\u003c\/td\u003e\n\u003ctd\u003eChain counter display and windlass sensor interface (not seen by the server).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-backbone\"\u003e\n\u003ch2 class=\"om-h\"\u003eInstalling the CAN Bus Backbone\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBackbone max 100 m, drop cables max 5 m each, bending radius greater than 40 mm. Exactly two terminations, one at each end.\u003c\/li\u003e\n\u003cli\u003eDrops connect through MMM junctions; where several drops start from one point, FMM junctions shorten the backbone. Use only the listed Quick cables.\u003c\/li\u003e\n\u003cli\u003eFeed the backbone through the power cable's MM junction, placed with an equal number of modules on each side, via an accessible switch (not supplied) and a fast-blow fuse sized by adding up the maximum current absorption of every module and rounding up to the next commercial size.\u003c\/li\u003e\n\u003cli\u003eNote each module's serial number and position while installing: you need them for the first configuration (each installation manual has a table for this).\u003c\/li\u003e\n\u003cli\u003ePanel modules (TJ\/WJ controls, DTW display): Ø 70 mm milling cutter for the body, Ø 2.5 mm pilot holes for the 4 screws; flush versions: 4 corner holes Ø 8 mm and cut along the template. Depth behind the panel: TJ\/WJ min. 100 mm (flush min. 115 mm), DTW min. 80 mm (flush min. 95 mm).\u003c\/li\u003e\n\u003cli\u003eBox modules (SRV, GTW, MCI, NCG, SVJB): 4 flat-head screws under 4 mm (not supplied), Ø 2.5 mm pilot in fibreglass, M4 on metal; smooth level surface, room above for the connectors. Put the SRV where its USB drive is reachable and the NCG near the OEM control unit.\u003c\/li\u003e\n\u003cli\u003eKeep modules at least 25 cm from the compass, 50 cm from radio receivers, 1 m from transmitters (except SSB) and 2 m from SSB transmitters and the radar beam.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"height:16px\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eBackbone accessory\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFCPCHEX00500A00\u003c\/td\u003e\n\u003ctd\u003ePCS\/CHC3 EX005 extension\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFCPCHEX01000A00\u003c\/td\u003e\n\u003ctd\u003ePCS\/CHC3 EX010 extension\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFCPCHEX03000A00\u003c\/td\u003e\n\u003ctd\u003ePCS\/CHC3 EX030 extension\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFCPCHEX05000A00\u003c\/td\u003e\n\u003ctd\u003ePCS\/CHC3 EX050 extension\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFCPCHEX10000A00\u003c\/td\u003e\n\u003ctd\u003ePCS\/CHC3 EX100 extension\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFCPCHEX15000A00\u003c\/td\u003e\n\u003ctd\u003ePCS\/CHC3 EX150 extension\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFCPCHEX20000A00\u003c\/td\u003e\n\u003ctd\u003ePCS\/CHC3 EX200 extension\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFCPCH2K02M00A00\u003c\/td\u003e\n\u003ctd\u003ePCS\/CHC2K PWR 2M power supply cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFCPCHTCNMMM0A00\u003c\/td\u003e\n\u003ctd\u003ePCS\/CHC3 TCN MMM 3-way junction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFCPCHTCNFMM0A00\u003c\/td\u003e\n\u003ctd\u003ePCS\/CHC3 TCN FMM 3-way junction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFCPCHMMJMM00A00\u003c\/td\u003e\n\u003ctd\u003ePCS\/CHC3 TCN MMJ 2-way MM junction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFCPCHTRM0000A00\u003c\/td\u003e\n\u003ctd\u003ePCS\/CHC2K TRM backbone termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-specs\"\u003e\n\u003ch2 class=\"om-h\"\u003eModule Technical Data\u003c\/h2\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eModule\u003c\/th\u003e\n\u003cth\u003eCurrent absorption\u003c\/th\u003e\n\u003cth\u003eMax. absorption (at 9 Vdc)\u003c\/th\u003e\n\u003cth\u003eProtection\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCS TJ1 \/ TJ1F \/ WJ1 \/ WJ1F\u003c\/td\u003e\n\u003ctd\u003e33 mA @ 12 V - 20 mA @ 24 V\u003c\/td\u003e\n\u003ctd\u003e117 mA\u003c\/td\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003ctd\u003e250 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCS TJ2 \/ TJ2F \/ WJ2 \/ WJ2F\u003c\/td\u003e\n\u003ctd\u003e46 mA @ 12 V - 26 mA @ 24 V\u003c\/td\u003e\n\u003ctd\u003e124 mA\u003c\/td\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003ctd\u003e325 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCS DTW \/ DTWF\u003c\/td\u003e\n\u003ctd\u003e31 mA @ 12 V - 18 mA @ 24 V\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003ctd\u003e175 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCS SRV\u003c\/td\u003e\n\u003ctd\u003e60 mA @ 12 V - 30 mA @ 24 V\u003c\/td\u003e\n\u003ctd\u003e110 mA\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCS GTW-A \/ GTW-B\u003c\/td\u003e\n\u003ctd\u003e40 mA @ 12 V - 20 mA @ 24 V\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCS MCI-A \/ MCI-B\u003c\/td\u003e\n\u003ctd\u003e50 mA @ 12 V - 25 mA @ 24 V\u003c\/td\u003e\n\u003ctd\u003e65 mA\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003ctd\u003e240 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCS NCG-T B01 (Mercury)\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e70 mA @ 9 Vdc\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCS NCG-T C02 (Volvo Penta)\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e500 mA @ 9 Vdc\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCS SVJB\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003ctd\u003e260 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp class=\"om-note\"\u003eAll powered modules: supply from 9 to 32 Vdc, operating temperature from -20°C to +70 °C, CAN bus. Below 0 °C the DTW display reacts more slowly. Use the maximum absorption column to size the backbone fuse.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-config\"\u003e\n\u003ch2 class=\"om-h\"\u003eFirst Configuration\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eAt first switch-on the DTW shows the MOTOR UNITS menu: BOW THRUSTER NO., STERN THRUSTER NO., WINDLASS NO. (if it does not, reset all associations from the SERVICE MENU → FACTORY SETTINGS).\u003c\/li\u003e\n\u003cli\u003eFor each actuator choose ONE or TWO, then pick the serial number of the interface module that drives it.\u003c\/li\u003e\n\u003cli\u003eSelect EXIT, then switch the PCS off and on at the power switch. The system works only when every detected interface module is assigned.\u003c\/li\u003e\n\u003cli\u003eSet DATE AND TIME in the MAIN MENU (hold SELECT 1.5 seconds); a wrong date\/time shows an error.\u003c\/li\u003e\n\u003cli\u003eIf an actuator turns the wrong way: SERVICE MENU (UP + DOWN together for 3 seconds) → PARAMETERS → INTERFACES → actuator → REV ROTATION = YES.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cul\u003e\n\u003cli\u003eSERVICE MENU parameters (changes need Quick's consent): ACC RAMP and DEC RAMP 0.3 s \/ 2.0, STOP INV TIME 0.3 s \/ 1.7 (GTW-B only), REV ROTATION; per-gateway PARITY; server N. ENABLED CONTROLS (ONE\/TWO) and SINGLE LEV PRIORITY.\u003c\/li\u003e\n\u003cli\u003eWith a PCS NCG-T B01 (Mercury) or C02 (Volvo Penta) gateway, set SERVER → N. ENABLED CONTROLS to TWO (the gateway supplements say to hold both arrow keys 1.5 seconds to enter the SERVICE MENU).\u003c\/li\u003e\n\u003cli\u003eNCG-T B01: isolated OEM CAN interface, not terminated internally, N2K pinout. NCG-T C02: isolated OEM bus supply (12 Vdc, 220 mA max), internal 120Ω termination, Volvo Penta adapter cable to the Thruster Control Module P\/N 24510291; requires Volvo Penta Assisted Docking (DPI and IPS 10, 15, 20 and 30) or Joystick Docking for single DPI, EVC2.0 25W49 or later, THCM software 24972444 via Autoconfig.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-operation\"\u003e\n\u003ch2 class=\"om-h\"\u003eUsing the PCS\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eA connected control flashes its green enable LED once per second. Hold the enable button for at least one second (1 s beep) to enable it; enabling another control of the same type disables the idle one.\u003c\/li\u003e\n\u003cli\u003eMove the levers: the arrow lights, the buzzer beeps once per second and the DTW shows the power used. Thrusters: the boat carries way after you let go.\u003c\/li\u003e\n\u003cli\u003eTwo controls can be active together only if one runs thrusters and the other windlasses, or (thrusters only) one is a PCS control and the other an OEM control on the NCG-T with N. ENABLED CONTROLS = TWO.\u003c\/li\u003e\n\u003cli\u003eHOLD (thrusters): set the levers, hold HOLD for 3 seconds, release both; the HOLD LED flashes orange and the beep doubles. Cancel with HOLD or a lever; it stops automatically after two minutes. Never leave the helm with HOLD on.\u003c\/li\u003e\n\u003cli\u003eAuto-disable after the DISABLING TIME set per control (1' - 10' or always enabled).\u003c\/li\u003e\n\u003cli\u003eDTW screens: summary (bars per actuator and \"PCS READY\"), one detail page per interface (power %, voltage, current, temperature where available), and the error list (press SELECT to scroll).\u003c\/li\u003e\n\u003cli\u003eModule STATUS LED (SRV, GTW, MCI, NCG, MCI CHC): green = powered and operating, orange = non-locking error, red = locking error. Error codes from the drives are listed with code and short text on the DTW; a \"Backdoor\" reset is SELECT (display) or ENABLE (control) held for 10 seconds.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-trouble\"\u003e\n\u003ch2 class=\"om-h\"\u003eTroubleshooting \u0026amp; Maintenance\u003c\/h2\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eProblem\u003c\/th\u003e\n\u003cth\u003eSolution\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModules not detected by the server\u003c\/td\u003e\n\u003ctd\u003eCheck the network connections and restart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModules report insufficient supply\u003c\/td\u003e\n\u003ctd\u003eLet the supply stabilise; check battery charge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCS control commands not executed correctly\u003c\/td\u003e\n\u003ctd\u003eContact a Quick service centre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM control commands not executed correctly\u003c\/td\u003e\n\u003ctd\u003eContact the OEM control supplier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATV DRIVE ERR. displayed\u003c\/td\u003e\n\u003ctd\u003eError from the Schneider ATV900 drive: see its documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware not updating\u003c\/td\u003e\n\u003ctd\u003eCheck the updated firmware is on the server's USB drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBow\/stern or left\/right windlass controls swapped\u003c\/td\u003e\n\u003ctd\u003eRe-assign the interfaces to the correct actuator positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThruster or windlass direction reversed vs. the lever\u003c\/td\u003e\n\u003ctd\u003eChange the REVERSE ROTATION parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp class=\"om-note\"\u003eMaintenance: check cables and connections once a year; clean displays and levers with a soft cloth dampened with water, no chemicals. Firmware is updated from the server's USB flash drive (MAIN MENU → SEARCH UPDATES).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp class=\"om-note\"\u003eNeed a part that isn't listed? \u003ca href=\"\/pages\/contact\"\u003eAsk us to source it\u003c\/a\u003e and quote the part number from the PDF.\u003c\/p\u003e\n\u003ch2 class=\"om-h\" id=\"om-products\"\u003eProducts in this Manual\u003c\/h2\u003e\n\u003c\/div\u003e","products":[],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/collections\/Quick-PCS-Proportional-Control-System-User-Manual-Cover.png?v=1792714421","url":"https:\/\/www.mauripro.com\/collections\/owners-manuals-quick-pcs-system.oembed","provider":"MAURIPRO Sailing","version":"1.0","type":"link"}