{"title":"Quick Q NCG-V B00 Gateway — Installation Manual","description":"\u003clink rel=\"stylesheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/om-manual-v2.css\"\u003e\u003cstyle\u003e.mpom .om-tbl.nw td+td{white-space:nowrap}.mpom details.om-dd{position:relative;margin:0}.mpom details.om-dd\u003esummary{list-style:none;cursor:pointer}.mpom details.om-dd\u003esummary::-webkit-details-marker{display:none}.mpom .om-dd-menu{position:absolute;left:0;top:calc(100% + 6px);min-width:100%;width:max-content;max-width:360px;background:#fff;border:1px solid #e3e5e8;border-radius:6px;box-shadow:0 8px 24px rgba(0,0,0,.14);z-index:30;padding:6px}.mpom .om-dd-menu a{display:flex;justify-content:space-between;align-items:center;gap:14px;padding:10px 12px;border-radius:4px;font-size:14px;font-weight:600;color:#2a2b2a!important;text-decoration:none!important}.mpom .om-dd-menu a:hover{background:#f5f6f8}.mpom .om-dd-menu small{font-weight:400;color:#5f6368;white-space:nowrap}\u003c\/style\u003e\u003cdiv class=\"mpom\"\u003e\n\u003cdiv class=\"om-head\"\u003e\n\u003cdiv\u003e\n\u003cspan class=\"om-tag\"\u003eINSTALLATION MANUAL\u003c\/span\u003e\u003cp class=\"om-lead\"\u003eInstallation of the Quick Q NCG-V B00 gateway that lets a Volvo Penta control system drive one BT QSY or BTQ (with MSC) thruster on the Quick \"Q Centric\" network: Volvo Penta requirements, wiring, status LED and technical data.\u003c\/p\u003e\n\u003cdiv class=\"om-box\"\u003e\n\u003cdiv class=\"om-row\"\u003e\n\u003cspan\u003eDocument\u003c\/span\u003e\u003cb\u003eQuick Q NCG-V B00 Gateway Installation Manual\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-row\"\u003e\n\u003cspan\u003eFormat\u003c\/span\u003e\u003cb\u003ePDF · 52 pages · 4.2 MB\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-row\" style=\"border-bottom:0\"\u003e\n\u003cspan\u003eLanguage\u003c\/span\u003e\u003cb\u003eEnglish\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-acts\"\u003e\u003ca class=\"om-btn dl\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Quick-Q-NCG-V-B00-Gateway-Installation-Manual.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003csvg viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2.4\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M12 4v11\"\u003e\u003c\/path\u003e\u003cpath d=\"m7 10 5 5 5-5\"\u003e\u003c\/path\u003e\u003cpath d=\"M5 20h14\"\u003e\u003c\/path\u003e\u003c\/svg\u003e Download PDF\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-toc\"\u003e\n\u003ca href=\"#om-system\"\u003eCompatibility\u003c\/a\u003e\u003ca href=\"#om-install\"\u003eInstallation\u003c\/a\u003e\u003ca href=\"#om-signals\"\u003eStatus LED\u003c\/a\u003e\u003ca href=\"#om-specs\"\u003eSpecifications\u003c\/a\u003e\u003ca href=\"#om-products\"\u003eProducts\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-img\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Quick-Q-NCG-V-B00-Gateway-Installation-Manual-Cover.png\" alt=\"Quick Q NCG-V B00 Gateway — Installation Manual\" loading=\"lazy\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-system\"\u003e\n\u003ch2 class=\"om-h\"\u003eWhat It Does \u0026amp; Requirements\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLets Volvo Penta control systems command ONE BT QSY or BTQ (with MSC) thruster on the \"Q Centric\" network.\u003c\/li\u003e\n\u003cli\u003eIsolated OEM CAN bus interface with isolated OEM network supply, integrated 120Ω termination, N2K-compliant pinout on the OEM connector; firmware update via USB-C; 12\/24 Vdc supply.\u003c\/li\u003e\n\u003cli\u003eIn the box: gateway, Volvo Penta OEM network NCG adapter cable, manual and warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"height:16px\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eVolvo Penta requirement\u003c\/th\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eVolvo Penta Assisted Docking for DPI and IPS (10, 15, 20 and 30); Volvo Penta Joystick Docking for single DPI engine installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003ctd\u003ePart Number 24510291 – CONVERTER, THRUSTER CONTROL MODULE (THCM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware\u003c\/td\u003e\n\u003ctd\u003eQuick proportional thrusters supported from EVC2.0 25W49; THCM software 24972444, loaded from the VMM during an Autoconfig in EVC (the THCM ships with older software). Older boats: update EVC2 with the VODIA aftermarket tool.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-install\"\u003e\n\u003ch2 class=\"om-h\"\u003eMounting \u0026amp; Wiring\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMount near the OEM system's communication control unit, accessible for maintenance, on a smooth, level surface with room above the front for the connectors.\u003c\/li\u003e\n\u003cli\u003eFix with 4 flat-head screws under 4 mm (not supplied): Ø 2.5 mm pilot holes in fibreglass, 4 M4 flat-head screws on metal. Do not overtighten.\u003c\/li\u003e\n\u003cli\u003eAt least 25 cm from the compass, 50 cm from radio receivers, 1 m from radio transmitters (except SSB), 2 m from SSB transmitters and the radar beam; cables 1 m from radio signal cables and 2 m from SSB transmitter cables.\u003c\/li\u003e\n\u003cli\u003eQ NETWORK: plug in the drop cable from the \"Q Centric\" network (max 5 m).\u003c\/li\u003e\n\u003cli\u003eOEM NETWORK: plug in the M12 female end of the supplied adapter cable; its other end goes to the Volvo Penta Thruster Control Module P\/N 24510291. OEM connector pins: VCC, GND, CAN H, CAN L.\u003c\/li\u003e\n\u003cli\u003eCheck all connections before powering up.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-signals\"\u003e\n\u003ch2 class=\"om-h\"\u003eStatus LED\u003c\/h2\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eLED\u003c\/th\u003e\n\u003cth\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff\u003c\/td\u003e\n\u003ctd\u003eNot powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteady green\u003c\/td\u003e\n\u003ctd\u003ePowered, no problems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteady orange\u003c\/td\u003e\n\u003ctd\u003eLow supply: below 9.5 V (clears above 10 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrange, 1 repeated flash\u003c\/td\u003e\n\u003ctd\u003eOEM network not connected (normal if the OEM system is off or disabled)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrange, 2 repeated flashes\u003c\/td\u003e\n\u003ctd\u003e\"Q Centric\" network not connected – check its connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrange, 3 repeated flashes\u003c\/td\u003e\n\u003ctd\u003eNeither network connected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRed, flashing very fast\u003c\/td\u003e\n\u003ctd\u003eCRC error flash: firmware corrupted – contact Quick\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRed, flashing fast\u003c\/td\u003e\n\u003ctd\u003eEEPROM CRC error: disconnect the power; at restart factory settings are restored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp class=\"om-note\"\u003eMaintenance: none special. Disconnect power, then clean the front with a soft cloth dampened with water; no chemicals.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-specs\"\u003e\n\u003ch2 class=\"om-h\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003efrom 9 to 32 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum current absorption\u003c\/td\u003e\n\u003ctd\u003e500 mA @ 9 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM bus supply\u003c\/td\u003e\n\u003ctd\u003e12 Vdc, 220 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination resistor\u003c\/td\u003e\n\u003ctd\u003e120 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003efrom -20 °C to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication interface\u003c\/td\u003e\n\u003ctd\u003e2x CAN bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC class\u003c\/td\u003e\n\u003ctd\u003eEN 60945 - FCC PART 15 rules 47\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"om-note\"\u003eNeed a part that isn't listed? \u003ca href=\"\/pages\/contact\"\u003eAsk us to source it\u003c\/a\u003e and quote the part number from the PDF.\u003c\/p\u003e\n\u003ch2 class=\"om-h\" id=\"om-products\"\u003eProducts in this Manual\u003c\/h2\u003e\n\u003c\/div\u003e","products":[],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/collections\/Quick-Q-NCG-V-B00-Gateway-Installation-Manual-Cover.png?v=1792714456","url":"https:\/\/www.mauripro.com\/collections\/owners-manuals-quick-q-ncg-v-gateway.oembed","provider":"MAURIPRO Sailing","version":"1.0","type":"link"}