{"title":"Quick QNN Quick Nautical Network — Installation \u0026 Use Manual","description":"\u003clink rel=\"stylesheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/om-manual-v2.css\"\u003e\u003cstyle\u003e.mpom .om-tbl.nw td+td{white-space:nowrap}.mpom details.om-dd{position:relative;margin:0}.mpom details.om-dd\u003esummary{list-style:none;cursor:pointer}.mpom details.om-dd\u003esummary::-webkit-details-marker{display:none}.mpom .om-dd-menu{position:absolute;left:0;top:calc(100% + 6px);min-width:100%;width:max-content;max-width:360px;background:#fff;border:1px solid #e3e5e8;border-radius:6px;box-shadow:0 8px 24px rgba(0,0,0,.14);z-index:30;padding:6px}.mpom .om-dd-menu a{display:flex;justify-content:space-between;align-items:center;gap:14px;padding:10px 12px;border-radius:4px;font-size:14px;font-weight:600;color:#2a2b2a!important;text-decoration:none!important}.mpom .om-dd-menu a:hover{background:#f5f6f8}.mpom .om-dd-menu small{font-weight:400;color:#5f6368;white-space:nowrap}\u003c\/style\u003e\u003cdiv class=\"mpom\"\u003e\n\u003cdiv class=\"om-head\"\u003e\n\u003cdiv\u003e\n\u003cspan class=\"om-tag\"\u003eINSTALLATION MANUAL\u003c\/span\u003e\u003cp class=\"om-lead\"\u003eInstallation, port allocation, MFD connection kits, network examples, the MFD control pages and technical data for the Quick QNN Quick Nautical Network gateway, which puts Quick windlasses, thrusters, gyro stabilizers, chargers, inverters and lighting on an HTML5 multifunction display.\u003c\/p\u003e\n\u003cdiv class=\"om-box\"\u003e\n\u003cdiv class=\"om-row\"\u003e\n\u003cspan\u003eDocument\u003c\/span\u003e\u003cb\u003eQuick QNN Quick Nautical Network Installation \u0026amp; Use Manual\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-row\"\u003e\n\u003cspan\u003eFormat\u003c\/span\u003e\u003cb\u003ePDF · 36 pages · 2.5 MB\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-row\" style=\"border-bottom:0\"\u003e\n\u003cspan\u003eLanguage\u003c\/span\u003e\u003cb\u003eEnglish\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-acts\"\u003e\u003ca class=\"om-btn dl\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Quick-QNN-Quick-Nautical-Network-Gateway-Installation-Use-Manual.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003csvg viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2.4\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M12 4v11\"\u003e\u003c\/path\u003e\u003cpath d=\"m7 10 5 5 5-5\"\u003e\u003c\/path\u003e\u003cpath d=\"M5 20h14\"\u003e\u003c\/path\u003e\u003c\/svg\u003e Download PDF\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-toc\"\u003e\n\u003ca href=\"#om-specs\"\u003eSpecifications\u003c\/a\u003e\u003ca href=\"#om-install\"\u003eInstallation\u003c\/a\u003e\u003ca href=\"#om-network\"\u003eNetwork\u003c\/a\u003e\u003ca href=\"#om-use\"\u003eUsing the QNN\u003c\/a\u003e\u003ca href=\"#om-products\"\u003eProducts\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-img\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Quick-QNN-Quick-Nautical-Network-Gateway-Installation-Use-Manual-Cover.png\" alt=\"Quick QNN Quick Nautical Network — Installation \u0026amp; Use Manual\" loading=\"lazy\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-specs\"\u003e\n\u003ch2 class=\"om-h\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eARM Cortex-A8 1000 MHz, Linux RT; 4 GB flash, 512 MB RAM, 64 KB FRAM; RTC back-up\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePorts\u003c\/td\u003e\n\u003ctd\u003e2 Ethernet (port 0 – 10\/100, port 1 – 10\/100); 1 USB host v. 2.0, max. 100 mA; 1 serial RS-485 (Modbus); 2 CAN bus (optocoupled – 1kV); 5 LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003efrom 9 to 32 Vdc; 0,15A max. at 24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003eOperating –15°C to +55°C; storage –20°C to +70°C; 5 – 85% RH non-condensing; IPX7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight \/ certification\u003c\/td\u003e\n\u003ctd\u003e280 g; EN 60945\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm, see drawing)\u003c\/td\u003e\n\u003ctd\u003e152 (5 63\/64), 132,5 (5 7\/32), 47 (1 27\/32), 30,5 (1 13\/64), 98 (3 55\/64), 118 (4 41\/64), 53 (2 3\/32); Ø 10 (25\/64) and Ø 5 (13\/64) holes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp class=\"om-note\"\u003eSupplied: QNN gateway, power supply cable, QR code sheet and warranty. For fixed indoor installation; the devices to be controlled must already be installed and powered.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block om-grid2\" id=\"om-install\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eMounting\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRoom for the wiring and easy access for maintenance and updates; clean, smooth, flat surface. Horizontal or vertical (on a bulkhead mind the cable direction).\u003c\/li\u003e\n\u003cli\u003eAt least 25 cm from the compass, 50 cm from radio receivers, 1 m from radio transmitters (2 m from SSB) and 2 m from the radar beam.\u003c\/li\u003e\n\u003cli\u003eMark the holes, pre-drill Ø 2.5 mm for the self-tapping screws, start the screws, slide the gateway so the screws sit in the slots and tighten all 4 (torque depends on the panel).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003ePorts\u003c\/h2\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePort\u003c\/th\u003e\n\u003cth\u003eConnects\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAN-0\u003c\/td\u003e\n\u003ctd\u003ePCS system (windlass, thrusters) at 250 Kbps via NCG-W \/ NCG-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAN-1\u003c\/td\u003e\n\u003ctd\u003eCHC chain counters, SBC NRG+ chargers, HSI inverters at 125 Kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETH-0\u003c\/td\u003e\n\u003ctd\u003eMultifunction display (MFD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETH-1\u003c\/td\u003e\n\u003ctd\u003eMC2 Quick Gyro remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePWR\/SER\u003c\/td\u003e\n\u003ctd\u003ePower supply and Modbus (LDIM lighting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003ctd\u003eSoftware upgrade, settings backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eLED\u003c\/th\u003e\n\u003cth\u003eState\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePOWER off \/ on\u003c\/td\u003e\n\u003ctd\u003eNo power \/ operating, last operation OK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePOWER slow \/ quick flash\u003c\/td\u003e\n\u003ctd\u003eError in last operation \/ operation in progress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETH green and red off\u003c\/td\u003e\n\u003ctd\u003eNo connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETH green flashing, red steady\u003c\/td\u003e\n\u003ctd\u003eConnected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block om-grid2\" id=\"om-network\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eDevice Requirements\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWindlass via PCS: NCG-W gateway, version 62.37 or higher; one or two windlasses. Via CHC chain counter (on\/off): CAN-1 at 125Kbps, one windlass only. CHC 1103 cannot be the only chain counter (needs a QNC CHC or other MASTER); CHC 1103 B can.\u003c\/li\u003e\n\u003cli\u003eThrusters: PCS with NCG-T gateway, version 60.37 or higher, and at least one Quick control. PCS controls have priority; the QNN works only when they are disabled.\u003c\/li\u003e\n\u003cli\u003eGyro: MC2 Quick Gyro remote panels on ETH-1. Chargers: SBC NRG+ Medium and High Power only, single or parallel, CAN-1 at 125 Kbps. Inverters: all HSI HR and LR, single or parallel.\u003c\/li\u003e\n\u003cli\u003eLighting: up to 20 LDIM RGBW 4CH dimmers (max 75W @ 12V – 150W @ 24V per channel), supply 10÷30 Vdc.\u003c\/li\u003e\n\u003cli\u003eCAN branch drops shown as maximum 5 m in the diagrams.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eAccessories (not supplied)\u003c\/h2\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFCQNNAUS0000A00\u003c\/td\u003e\n\u003ctd\u003eQNN USB adapter (update)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFNQNNRJ45M12A00\u003c\/td\u003e\n\u003ctd\u003eQNN ASH SBC NRG+\/HSI adapter cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFCQNNGTWRCM0A00\u003c\/td\u003e\n\u003ctd\u003eQNN CGY GTW-RC MC2X QNN cable, Ethernet (2M – 6,5ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFCQNNGTWNV00A00\u003c\/td\u003e\n\u003ctd\u003eQNN CNA GTW-Navico cable (Simrad, Lowrance, B\u0026amp;G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFCQNNGTWGR00A00\u003c\/td\u003e\n\u003ctd\u003eQNN CGA GTW-Garmin cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFCQNNGTWRM00A00\u003c\/td\u003e\n\u003ctd\u003eQNN CRA GTW-Raymarine cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFCQNNGTWFU00A00\u003c\/td\u003e\n\u003ctd\u003eQNN CFU GTW-Furuno cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp class=\"om-note\"\u003eCompatible MFDs must support HTML5 (OneHelm on Garmin): the manual lists models from Simrad, B\u0026amp;G, Lowrance, Garmin, Raymarine and Furuno.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block om-grid2\" id=\"om-use\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003ePages on the MFD\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFirst start: the QNN icon appears on the MFD home page (on some MFDs create the link manually); \"NO HARDWARE DETECTED\" shows for a few seconds before the home page.\u003c\/li\u003e\n\u003cli\u003eHome: connected devices active, others greyed. Setup: login (Quick technicians), units INT or US\/UK, clear device list, save\/load settings to a FAT32 USB stick via the USB adapter.\u003c\/li\u003e\n\u003cli\u003eAnchoring: hold red to raise, green to drop (A left \/ B right windlass); hold ZERO 5 seconds to reset the chain count; set total chain length and time-out (default 10 minutes); warping mode with PCS only.\u003c\/li\u003e\n\u003cli\u003eThrusters: proportional keys 25%, 50%, 75%, 100%, one thruster at a time; manoeuvring keys act for 5 seconds then stop even if held.\u003c\/li\u003e\n\u003cli\u003eGyro: on\/off, speed, precession and angle (not on X2 and X3). Chargers: voltages, current, status, output and Energy Saving. Inverter: status, voltages, output power, ON\/LP and ON\/STAND BY.\u003c\/li\u003e\n\u003cli\u003eLighting: up to 10 rooms and 12 zones per room; RGB, dynamic white, monochromatic and cold white – blue sources; hold POWER 100% for 2 seconds for all zones full on.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eTroubleshooting \u0026amp; Care\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThe QNN does NOT replace the dedicated Quick control panels: if it misbehaves, use each product's own panel.\u003c\/li\u003e\n\u003cli\u003eDisplay errors or crashes: Setup \u0026gt; Clear device list, then switch the gateway off and on; if it persists contact Quick service.\u003c\/li\u003e\n\u003cli\u003eAlarms page: active alarms with state, time and description, plus history (default period 5 Min).\u003c\/li\u003e\n\u003cli\u003eNo special maintenance: check cables and connections yearly; clean with a soft cloth moistened with water, no chemicals. Do not remove the hazard labels; dispose of the internal battery per local rules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"om-note\"\u003eNeed a part that isn't listed? \u003ca href=\"\/pages\/contact\"\u003eAsk us to source it\u003c\/a\u003e and quote the part number from the PDF.\u003c\/p\u003e\n\u003ch2 class=\"om-h\" id=\"om-products\"\u003eProducts in this Manual\u003c\/h2\u003e\n\u003c\/div\u003e","products":[],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/collections\/Quick-QNN-Quick-Nautical-Network-Gateway-Installation-Use-Manual-Cover.png?v=1792719472","url":"https:\/\/www.mauripro.com\/collections\/owners-manuals-quick-qnn-quick-nautical-network.oembed","provider":"MAURIPRO Sailing","version":"1.0","type":"link"}