{"title":"Quick RDS 1562 Remote Display — Installation \u0026 Use Manual","description":"\u003clink rel=\"stylesheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/om-manual-v2.css\"\u003e\u003cstyle\u003e.mpom .om-tbl.nw td+td{white-space:nowrap}.mpom details.om-dd{position:relative;margin:0}.mpom details.om-dd\u003esummary{list-style:none;cursor:pointer}.mpom details.om-dd\u003esummary::-webkit-details-marker{display:none}.mpom .om-dd-menu{position:absolute;left:0;top:calc(100% + 6px);min-width:100%;width:max-content;max-width:360px;background:#fff;border:1px solid #e3e5e8;border-radius:6px;box-shadow:0 8px 24px rgba(0,0,0,.14);z-index:30;padding:6px}.mpom .om-dd-menu a{display:flex;justify-content:space-between;align-items:center;gap:14px;padding:10px 12px;border-radius:4px;font-size:14px;font-weight:600;color:#2a2b2a!important;text-decoration:none!important}.mpom .om-dd-menu a:hover{background:#f5f6f8}.mpom .om-dd-menu small{font-weight:400;color:#5f6368;white-space:nowrap}\u003c\/style\u003e\u003cdiv class=\"mpom\"\u003e\n\u003cdiv class=\"om-head\"\u003e\n\u003cdiv\u003e\n\u003cspan class=\"om-tag\"\u003eINSTALLATION MANUAL\u003c\/span\u003e\u003cp class=\"om-lead\"\u003eInstallation, CAN wiring, menus, charger settings (group, priority, monitor, float threshold, current limit, silent mode), messages and technical data for the Quick RDS 1562 remote display for SBC NRG+ Medium and High Power chargers, with the 1:1 drill template.\u003c\/p\u003e\n\u003cdiv class=\"om-box\"\u003e\n\u003cdiv class=\"om-row\"\u003e\n\u003cspan\u003eDocument\u003c\/span\u003e\u003cb\u003eQuick RDS 1562 Remote Display Installation \u0026amp; Use Manual\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-row\"\u003e\n\u003cspan\u003eFormat\u003c\/span\u003e\u003cb\u003ePDF · 36 pages · 1.9 MB\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-row\" style=\"border-bottom:0\"\u003e\n\u003cspan\u003eLanguage\u003c\/span\u003e\u003cb\u003eEnglish\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-acts\"\u003e\u003cdetails class=\"om-dd\"\u003e\u003csummary class=\"om-btn dl\"\u003e\u003csvg viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2.4\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M12 4v11\"\u003e\u003c\/path\u003e\u003cpath d=\"m7 10 5 5 5-5\"\u003e\u003c\/path\u003e\u003cpath d=\"M5 20h14\"\u003e\u003c\/path\u003e\u003c\/svg\u003e Download PDF ▾\u003c\/summary\u003e\u003cdiv class=\"om-dd-menu\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Quick-RDS-1562-Remote-Display-Installation-Use-Manual.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003eInstallation Manual\u003c\/span\u003e\u003csmall\u003ePDF · 36 p.\u003c\/small\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Quick-RDS-1562-RDH-1660-Drill-Template.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003eDrill template RDS 1562 \/ RDH 1660 (1:1)\u003c\/span\u003e\u003csmall\u003ePDF · 1 p.\u003c\/small\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-toc\"\u003e\n\u003ca href=\"#om-specs\"\u003eSpecifications\u003c\/a\u003e\u003ca href=\"#om-install\"\u003eInstallation\u003c\/a\u003e\u003ca href=\"#om-menu\"\u003eMenus\u003c\/a\u003e\u003ca href=\"#om-trouble\"\u003eMessages\u003c\/a\u003e\u003ca href=\"#om-products\"\u003eProducts\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-img\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Quick-RDS-1562-Remote-Display-Installation-Use-Manual-Cover.png\" alt=\"Quick RDS 1562 Remote Display — Installation \u0026amp; Use Manual\" loading=\"lazy\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-specs\"\u003e\n\u003ch2 class=\"om-h\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage (1)\u003c\/td\u003e\n\u003ctd\u003efrom 9 to 32 Vdc (powered through the CAN cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum current (2)\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (3)\u003c\/td\u003e\n\u003ctd\u003efrom –15 °C to + 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e105 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eCAN BUS with differential transceiver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eEN60945 – FCC Title 47 Part 15 Subpart B Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm, see drawing)\u003c\/td\u003e\n\u003ctd\u003e116,5 (4 19\/32), 77,2 (3 1\/32), 102,3 (4 1\/32), 27,2 (1 3\/4), 7 (1 7\/64)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e(1) May reset below 9 Vdc. (2) Typical, backlight at high intensity. (3) Below 0 °C the display slows down.\u003c\/li\u003e\n\u003cli\u003eShows the three charger output voltages and total current; backlight 6 levels, contrast 5 levels, audible alarm, reverse polarity protection.\u003c\/li\u003e\n\u003cli\u003ePackage: RDS 1562, frame, drilling template, connecting cable, 2 termination connectors, manual, warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block om-grid2\" id=\"om-install\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eMounting\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEasy to read; clean, smooth, flat surface; rear access and room for the connectors; back of the unit protected from water.\u003c\/li\u003e\n\u003cli\u003eAt least 25 cm from the compass, 50 cm from radio receivers, 1 m from radio transmitters (2 m from SSB) and 2 m from radar beams.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003col\u003e\n\u003cli\u003ePlace the drilling template, mark the hole centres and cut the opening.\u003c\/li\u003e\n\u003cli\u003eRemove the template and deburr.\u003c\/li\u003e\n\u003cli\u003eFit the display with four countersunk screws (not supplied) and clip on the frame.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cdiv\u003e\n\u003ch3 class=\"om-h3\"\u003eDrill template (RDS 1562 \/ RDH 1660)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrint at 100% and check the 100mm scale bar before cutting.\u003c\/li\u003e\n\u003cli\u003eø40 (ø1\" 9\/16) opening and four ø3 (ø 1\/8) holes, 63.2 (2\" 1\/2) as drawn.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eWiring\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAlways connect the RDS 1562 to the charger's CAN OUT port, ferrite end of the patch cord at the charger; fit the termination connector in the display's second RJ45.\u003c\/li\u003e\n\u003cli\u003eUse the supplied cable or a UTP CAT5 patch cord; data cable max 100 meters; keep cables 1 m from radio signal cables (2 m from SSB).\u003c\/li\u003e\n\u003cli\u003eIn \"monitor\" mode the display keeps reading voltages with the charger off, powered from the MASTER battery bank.\u003c\/li\u003e\n\u003cli\u003eIn parallel (current sharing) networks each end of the CAN chain needs a termination connector.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block om-grid2\" id=\"om-menu\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eUsing the Display\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eStart-up shows the software version for 2 seconds, then the charger data.\u003c\/li\u003e\n\u003cli\u003eHold ENTER 3 seconds to enter the main menu; UP\/DOWN to scroll, ENTER to select.\u003c\/li\u003e\n\u003cli\u003ePress UP and DOWN together to silence the alarm; press DOWN + ENTER briefly for stand-by.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eOptions (factory *)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd\u003eDisplay only: open, sealed, Gel, AGM, AGM spiral, Li-Ion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAN group\u003c\/td\u003e\n\u003ctd\u003eA *, B, C (group U talks to all)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAN priority\u003c\/td\u003e\n\u003ctd\u003e1 *, 2, 3: only for chargers in parallel; one must be PRIORITY 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitor mode\u003c\/td\u003e\n\u003ctd\u003eDisable * \/ Enable: charger stays on the CAN with no AC (below 70 mA); off below 7 Vdc (12 V) \/ 14 Vdc (24 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFloat threshold\u003c\/td\u003e\n\u003ctd\u003e10%, 15%, 20% *, 25%, 30% of rated current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax current\u003c\/td\u003e\n\u003ctd\u003e100% *, 90%, 80%, 70%, 60%, 50%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilent mode\u003c\/td\u003e\n\u003ctd\u003eDisable * \/ Enable: lower fan speed, current derated with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset\u003c\/td\u003e\n\u003ctd\u003eResets the charger, including manual-reset errors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eConfig RDS\u003c\/h2\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSetting\u003c\/th\u003e\n\u003cth\u003eOptions (factory *)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguage\u003c\/td\u003e\n\u003ctd\u003eEnglish *, Italiano, Francais, Espanol, Deutsch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRDS group \/ priority\u003c\/td\u003e\n\u003ctd\u003eMust match the charger to be displayed: A * \/ 1 *\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet scanning\u003c\/td\u003e\n\u003ctd\u003eLists group and priority of every charger on the CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBeep alert\u003c\/td\u003e\n\u003ctd\u003eOn warnings (slow beep) \/ on errors (fast beep): Enable *\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKey beep\u003c\/td\u003e\n\u003ctd\u003eEnable *\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003e10%, 30%, 50% *, 70%, 90%, 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLCD contrast\u003c\/td\u003e\n\u003ctd\u003e3 *\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp class=\"om-note\"\u003eChange group and priority on one charger at a time, switching chargers on one by one. In current-sharing mode, monitor, float threshold, max current and silent mode must be the same on all chargers.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-trouble\"\u003e\n\u003ch2 class=\"om-h\"\u003eMessages\u003c\/h2\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eMessage\u003c\/th\u003e\n\u003cth\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvertemperat\u003c\/td\u003e\n\u003ctd\u003eAmbient too hot for regular operation: check location\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFan blocked\u003c\/td\u003e\n\u003ctd\u003eOne fan blocked; output limited: service point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC low\u003c\/td\u003e\n\u003ctd\u003eMains below 207 Vac (1450, 1950, 2450 HR) or 108 Vac (600 – 1200 FR): output limited to 70%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC fail\u003c\/td\u003e\n\u003ctd\u003eMains below 161 Vac (HR) or 83 Vac (FR): output suspended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCold \/ Hot battery\u003c\/td\u003e\n\u003ctd\u003eBattery sensor below –15 °C or above +50 °C: output suspended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor fault\u003c\/td\u003e\n\u003ctd\u003eOne internal temperature sensor failed: service point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAN error\u003c\/td\u003e\n\u003ctd\u003eCommunication errors: check CAN wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatt M \/ 1 \/ 2 lo, hi\u003c\/td\u003e\n\u003ctd\u003eOutput voltage below 11 Vdc \/ 22 Vdc or above 14,8 Vdc \/ 29,6 Vdc (12 V \/ 24 V models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBulk, Absorption, Float, Derating, Monitor, Limit power, Silent mode, Sharing on, Charge comp\u003c\/td\u003e\n\u003ctd\u003eStatus messages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProblem XX\u003c\/td\u003e\n\u003ctd\u003eManual-reset problem: see the charger manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash check sum error\u003c\/td\u003e\n\u003ctd\u003eDisplay memory checksum error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo link\u003c\/td\u003e\n\u003ctd\u003eGroup\/priority in Config RDS do not match the charger, or CAN line problem: check wiring and termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel not recognized\u003c\/td\u003e\n\u003ctd\u003eCharger model not recognised\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp class=\"om-note\"\u003eMaintenance: none special; check cables and connections yearly, clean with a soft damp cloth, no chemical or abrasive products.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp class=\"om-note\"\u003eNeed a part that isn't listed? \u003ca href=\"\/pages\/contact\"\u003eAsk us to source it\u003c\/a\u003e and quote the part number from the PDF.\u003c\/p\u003e\n\u003ch2 class=\"om-h\" id=\"om-products\"\u003eProducts in this Manual\u003c\/h2\u003e\n\u003c\/div\u003e","products":[],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/collections\/Quick-RDS-1562-Remote-Display-Installation-Use-Manual-Cover.png?v=1792714957","url":"https:\/\/www.mauripro.com\/collections\/owners-manuals-quick-rds-1562-remote-display.oembed","provider":"MAURIPRO Sailing","version":"1.0","type":"link"}