{"title":"Quick SBC NRG+ 600, 700, 750 \u0026 950 Battery Chargers — Installation \u0026 Use Manual","description":"\u003clink rel=\"stylesheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/om-manual-v2.css\"\u003e\u003cstyle\u003e.mpom .om-tbl.nw td+td{white-space:nowrap}.mpom details.om-dd{position:relative;margin:0}.mpom details.om-dd\u003esummary{list-style:none;cursor:pointer}.mpom details.om-dd\u003esummary::-webkit-details-marker{display:none}.mpom .om-dd-menu{position:absolute;left:0;top:calc(100% + 6px);min-width:100%;width:max-content;max-width:360px;background:#fff;border:1px solid #e3e5e8;border-radius:6px;box-shadow:0 8px 24px rgba(0,0,0,.14);z-index:30;padding:6px}.mpom .om-dd-menu a{display:flex;justify-content:space-between;align-items:center;gap:14px;padding:10px 12px;border-radius:4px;font-size:14px;font-weight:600;color:#2a2b2a!important;text-decoration:none!important}.mpom .om-dd-menu a:hover{background:#f5f6f8}.mpom .om-dd-menu small{font-weight:400;color:#5f6368;white-space:nowrap}\u003c\/style\u003e\u003cdiv class=\"mpom\"\u003e\n\u003cdiv class=\"om-head\"\u003e\n\u003cdiv\u003e\n\u003cspan class=\"om-tag\"\u003eINSTALLATION MANUAL\u003c\/span\u003e\u003cp class=\"om-lead\"\u003eBattery and cable sizing, wiring, CAN signals, battery type selection, LEDs, charging stages, fault codes and technical data for the Quick SBC NRG+ Medium Power chargers: 600 and 700 FR (12 V), 750 and 950 FR (24 V).\u003c\/p\u003e\n\u003cdiv class=\"om-box\"\u003e\n\u003cdiv class=\"om-row\"\u003e\n\u003cspan\u003eDocument\u003c\/span\u003e\u003cb\u003eQuick SBC NRG+ 600, 700, 750 \u0026amp; 950 Battery Chargers Installation \u0026amp; Use Manual\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-row\"\u003e\n\u003cspan\u003eFormat\u003c\/span\u003e\u003cb\u003ePDF · 28 pages · 0.9 MB\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-row\" style=\"border-bottom:0\"\u003e\n\u003cspan\u003eLanguage\u003c\/span\u003e\u003cb\u003eEnglish\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-acts\"\u003e\n\u003ca class=\"om-btn dl\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Quick-SBC-NRG-Plus-600-950-Battery-Charger-Installation-Use-Manual.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003csvg viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2.4\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M12 4v11\"\u003e\u003c\/path\u003e\u003cpath d=\"m7 10 5 5 5-5\"\u003e\u003c\/path\u003e\u003cpath d=\"M5 20h14\"\u003e\u003c\/path\u003e\u003c\/svg\u003e Download PDF\u003c\/a\u003e\u003ca class=\"om-btn buy\" href=\"\/collections\/quick-battery-chargers\"\u003eView Collection\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-toc\"\u003e\n\u003ca href=\"#om-specs\"\u003eSpecifications\u003c\/a\u003e\u003ca href=\"#om-install\"\u003eInstallation \u0026amp; Wiring\u003c\/a\u003e\u003ca href=\"#om-use\"\u003eOperation \u0026amp; Faults\u003c\/a\u003e\u003ca href=\"#om-products\"\u003eProducts\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-img\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/QCKFBNRP0700FR0A00.jpg?v=1728056624\" alt=\"Quick SBC NRG+ 600, 700, 750 \u0026amp; 950 Battery Chargers — Installation \u0026amp; Use Manual\" loading=\"lazy\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-specs\"\u003e\n\u003ch2 class=\"om-h\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eSBC 600 NRG+ FR\u003c\/th\u003e\n\u003cth\u003eSBC 700 NRG+ FR\u003c\/th\u003e\n\u003cth\u003eSBC 750 NRG+ FR\u003c\/th\u003e\n\u003cth\u003eSBC 950 NRG+ FR\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery voltage\u003c\/td\u003e\n\u003ctd\u003e12 V\u003c\/td\u003e\n\u003ctd\u003e12 V\u003c\/td\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum output current (1)\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003ctd\u003e60 A\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery capacity\u003c\/td\u003e\n\u003ctd\u003e230 ÷ 500 Ah\u003c\/td\u003e\n\u003ctd\u003e270 ÷ 600 Ah\u003c\/td\u003e\n\u003ctd\u003e140 ÷ 300 Ah\u003c\/td\u003e\n\u003ctd\u003e180 ÷ 400 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. output cable\u003c\/td\u003e\n\u003ctd\u003e16 mm2\u003c\/td\u003e\n\u003ctd\u003e16 mm2\u003c\/td\u003e\n\u003ctd\u003e10 mm2\u003c\/td\u003e\n\u003ctd\u003e16 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax absorption 230\/240 Vac (5)\u003c\/td\u003e\n\u003ctd\u003e3,4 A\u003c\/td\u003e\n\u003ctd\u003e3,9 A\u003c\/td\u003e\n\u003ctd\u003e4,2 A\u003c\/td\u003e\n\u003ctd\u003e5,1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax absorption 120 Vac (6)\u003c\/td\u003e\n\u003ctd\u003e6,5 A\u003c\/td\u003e\n\u003ctd\u003e7,5 A\u003c\/td\u003e\n\u003ctd\u003e7,9 A\u003c\/td\u003e\n\u003ctd\u003e10,0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency (5)\u003c\/td\u003e\n\u003ctd\u003e≥ 90%\u003c\/td\u003e\n\u003ctd\u003e≥ 90%\u003c\/td\u003e\n\u003ctd\u003e≥ 92%\u003c\/td\u003e\n\u003ctd\u003e≥ 92%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC drain from batteries (2)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 3,5 mA\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 3,5 mA\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 mA\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual ripple (3)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 100 mV RMS\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 100 mV RMS\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 150 mV RMS\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 150 mV RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv style=\"height:16px\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery type\u003c\/th\u003e\n\u003cth\u003eAbsorption 12 V \/ 24 V\u003c\/th\u003e\n\u003cth\u003eFloat 12 V \/ 24 V\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEL open\u003c\/td\u003e\n\u003ctd\u003e14,1 \/ 28,2 Vdc\u003c\/td\u003e\n\u003ctd\u003e13,4 \/ 26,8 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEL sealed \/ Gel\u003c\/td\u003e\n\u003ctd\u003e14,4 \/ 28,8 Vdc\u003c\/td\u003e\n\u003ctd\u003e13,8 \/ 27,6 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAGM\u003c\/td\u003e\n\u003ctd\u003e14,4 \/ 28,8 Vdc\u003c\/td\u003e\n\u003ctd\u003e13,6 \/ 27,2 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptima®\u003c\/td\u003e\n\u003ctd\u003e14,7 \/ 29,4 Vdc\u003c\/td\u003e\n\u003ctd\u003e13,8 \/ 27,6 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLi-Ion\u003c\/td\u003e\n\u003ctd\u003e14,2 \/ 28,4 Vdc\u003c\/td\u003e\n\u003ctd\u003e13,5 \/ 27,0 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e3 outputs (4); three-stage IUoU; supply 264 ÷ 83 Vac with power reduction under 108 Vac; rated 120 - 240 Vac; 45÷66 Hz; power factor 1,00.\u003c\/li\u003e\n\u003cli\u003eOperating –15 ÷ +70 °C, linear power reduction over +50 °C; forced cooling, variable fan speed; humidity max. 95% without condensation; aluminium case 170 x 391 x 82mm; 3,1 kg.\u003c\/li\u003e\n\u003cli\u003eProtections: reverse polarity (through fuse), overload, output short circuit, output overvoltage (8), overheating, battery overtemperature (optional). CAN bus. Charge compensation: 1 sensor supplied, up to 128 sensors.\u003c\/li\u003e\n\u003cli\u003eEN 60335-2-29; EN 55032\/A – FCC Title 47 Part 15 Subpart B Class A.\u003c\/li\u003e\n\u003cli\u003e(1) Max at normal use or short circuit. (2) No AC, monitor mode off, no LCD. (3) At 50% load, resistive. (4) Each output can give full current; the sum cannot exceed the rating. (5) At 230 Vac, full output. (6) At 120 Vac, full output. (8) Software\/hardware double-check.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"om-note\"\u003eOur store lists the 700 as \"SBC 700 Nrg Battery Charger Fr – 12V – 60 Amp\".\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block om-grid2\" id=\"om-install\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eLocation \u0026amp; Supply\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAs close to the batteries as possible, dry and airy; horizontal or vertical with the output connector facing down (vertical preferred); 5 cm clearance all round (excluding the base). Units in parallel side by side.\u003c\/li\u003e\n\u003cli\u003eOutput wires max 4 meters. 6 cells (12 V) or 12 cells (24 V).\u003c\/li\u003e\n\u003cli\u003eRechargeable lead (open or sealed), Gel, AGM, Optima® and Li-Ion batteries only.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eAC cord supplied: brown\/black 1 live, blue\/black 2 neutral, yellow-green earth. Fit an overvoltage category III switch for on\/off only; check the rating label matches the mains; wire to local codes.\u003c\/li\u003e\n\u003cli\u003eDisconnect AC (bipolar switch) and the batteries (isolator) before touching the DC terminals. A damaged AC cord must be replaced by a Quick service centre.\u003c\/li\u003e\n\u003cli\u003eBatteries gas while charging: ventilate the battery area, no sparks or naked flames. Check polarity before connecting: reversal can seriously damage the charger even though it is fused.\u003c\/li\u003e\n\u003cli\u003eBattery positive to an output positive, negative to the charger negative, with the supplied terminals. With one or two banks always use MASTER (main output), ideally for the most-used (service) bank. Leave unused outputs free: never bridge them.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eCAN IN \/ CAN OUT (RJ45)\u003c\/h2\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePin\u003c\/th\u003e\n\u003cth\u003eCAN IN\u003c\/th\u003e\n\u003cth\u003eCAN OUT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eCANL\u003c\/td\u003e\n\u003ctd\u003eCANL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eCANH\u003c\/td\u003e\n\u003ctd\u003eCANH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eReserved\u003c\/td\u003e\n\u003ctd\u003eUnconnected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eReserved\u003c\/td\u003e\n\u003ctd\u003eCharger status (≈ +13,5 Vdc \/ 20 mA max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eReserved\u003c\/td\u003e\n\u003ctd\u003eCharger negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003eReserved\u003c\/td\u003e\n\u003ctd\u003eUnconnected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003eUnconnected\u003c\/td\u003e\n\u003ctd\u003eMASTER output voltage (100 mA limited)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003eCAN BUS terminator (120 ohm)\u003c\/td\u003e\n\u003ctd\u003eCAN BUS terminator (120 ohm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003ePin 4 status: high impedance = off or manual-reset fault; ≈ + 13,6 Vdc = on with no manual-reset fault.\u003c\/li\u003e\n\u003cli\u003eKTBRJ battery temperature sensor on the RJ11 socket (disabled automatically when a KTB4N interface is connected).\u003c\/li\u003e\n\u003cli\u003eBattery selector (front panel, charger off): 0 EL open (factory), 1 EL sealed, 2 GEL, 3 AGM, 4 Optima®, 5 Li-Ion; 6–9 reserved.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block om-grid2\" id=\"om-use\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eLEDs \u0026amp; Charging\u003c\/h2\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eLED\u003c\/th\u003e\n\u003cth\u003eState\u003c\/th\u003e\n\u003cth\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSTATUS\u003c\/td\u003e\n\u003ctd\u003eOff \/ green \/ orange \/ red\u003c\/td\u003e\n\u003ctd\u003eNo mains or active error \/ FLOAT \/ ABSORPTION \/ BULK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSTATUS\u003c\/td\u003e\n\u003ctd\u003eQuick \/ slow flash\u003c\/td\u003e\n\u003ctd\u003ePower reduction \/ charge compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSTATUS\u003c\/td\u003e\n\u003ctd\u003eShort green pulse \/ green pulse\u003c\/td\u003e\n\u003ctd\u003eMonitor mode \/ stand-by\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eERROR\u003c\/td\u003e\n\u003ctd\u003eOff \/ flashing \/ red\u003c\/td\u003e\n\u003ctd\u003eNo problem \/ manual-reset problem \/ automatic-reset problem\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOUT CURRENT\u003c\/td\u003e\n\u003ctd\u003eGreen, orange, orange, red\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;2%, \u0026gt;25%, \u0026gt;50%, \u0026gt;75% of max current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eBULK: constant current at the maximum (or reduced) rating, at start-up, with flat batteries or a heavy load.\u003c\/li\u003e\n\u003cli\u003eABSORPTION: constant voltage while the current drawn is above the ABSORPTION–FLOAT threshold (20% of maximum output current).\u003c\/li\u003e\n\u003cli\u003eFLOAT: maintenance voltage once the current falls below the threshold; batteries can stay on charge without overcharging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eFault Codes (ERROR LED flashes)\u003c\/h2\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eFlashes\u003c\/th\u003e\n\u003cth\u003eProblem\u003c\/th\u003e\n\u003cth\u003eAction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eOutput short circuit or overload (auto reset)\u003c\/td\u003e\n\u003ctd\u003eCheck output wiring, battery bank and loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eOutput fuse open (likely reversed battery polarity)\u003c\/td\u003e\n\u003ctd\u003eQuick service center\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eOutput overvoltage\u003c\/td\u003e\n\u003ctd\u003eQuick service center\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eExtended output overload\u003c\/td\u003e\n\u003ctd\u003eCheck battery bank and loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003eBoth fans blocked\u003c\/td\u003e\n\u003ctd\u003eQuick service center\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003eTwo chargers in a group with the same priority\u003c\/td\u003e\n\u003ctd\u003eCheck group and priority with the RDS 1562\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003eBoth internal temperature sensors faulty\u003c\/td\u003e\n\u003ctd\u003eQuick service center\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003eBULK phase over 8 hours (default)\u003c\/td\u003e\n\u003ctd\u003eCheck batteries and loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003eABSORPTION phase over 24 hours (default); output held at FLOAT\u003c\/td\u003e\n\u003ctd\u003eCheck batteries and loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eManual reset: remove the cause, disconnect AC for 10 seconds, reconnect.\u003c\/li\u003e\n\u003cli\u003eAutomatic-reset problems (red ERROR LED): over temperature, blocked fan, AC low (below 108 Vac: output limited to 70%), AC fail (below 83 Vac: output suspended), cold battery (\u0026lt; –15°C), hot battery (\u0026gt; +50°C), sensor fault, CAN error.\u003c\/li\u003e\n\u003cli\u003eMaintenance: none; check cables and connections once a year.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"om-note\"\u003eNeed a part that isn't listed? \u003ca href=\"\/pages\/contact\"\u003eAsk us to source it\u003c\/a\u003e and quote the part number from the PDF.\u003c\/p\u003e\n\u003ch2 class=\"om-h\" id=\"om-products\"\u003eProducts in this Manual\u003c\/h2\u003e\n\u003c\/div\u003e","products":[{"product_id":"qckfbnrp0700fr0a00","title":"Quick Chargers - SBC 700 Nrg Battery Charger Fr - 12V - 60 Amp","description":"\u003cp\u003eThe new SBC NRG+ battery chargers are more compact and equipped with connectors which make their connection easy and practical. Thanks to their efficiency (up to 92%), they are capable of offering a much lower consumption, a lower heat emission and a greater system's reliability.\u003c\/p\u003e\u003cp\u003eSafety classification EN 60335-2-29\u003c\/p\u003e\u003cp\u003eEMC Class EN 55022\/A\u003c\/p\u003e\u003cp\u003eFCC TITLE 47 PART 15 SUBPART B CLASS A\u003c\/p\u003e\u003cp\u003eOur Part # QCKFBNRP0700FR0A00 | Mfr. Part # FBNRP0700FR0A00\u003c\/p\u003e","brand":"Quick","offers":[{"title":"Default Title","offer_id":49349067833650,"sku":"QCKFBNRP0700FR0A00","price":1660.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/QCKFBNRP0700FR0A00.jpg?v=1728056624"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/collections\/QCKFBNRP0700FR0A00.jpg?v=1792714849","url":"https:\/\/www.mauripro.com\/collections\/owners-manuals-quick-sbc-nrg-plus-600-950-battery-charger.oembed","provider":"MAURIPRO Sailing","version":"1.0","type":"link"}