{"title":"Ronstan RFC2433-09 Removable Screw-In Padeye Anchor Device — User Instructions","description":"\u003clink rel=\"stylesheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/om-manual-v2.css\"\u003e\u003cstyle\u003e.mpom .om-tbl.nw td+td{white-space:nowrap}.mpom details.om-dd{position:relative;margin:0}.mpom details.om-dd\u003esummary{list-style:none;cursor:pointer}.mpom details.om-dd\u003esummary::-webkit-details-marker{display:none}.mpom .om-dd-menu{position:absolute;left:0;top:calc(100% + 6px);min-width:100%;width:max-content;max-width:360px;background:#fff;border:1px solid #e3e5e8;border-radius:6px;box-shadow:0 8px 24px rgba(0,0,0,.14);z-index:30;padding:6px}.mpom .om-dd-menu a{display:flex;justify-content:space-between;align-items:center;gap:14px;padding:10px 12px;border-radius:4px;font-size:14px;font-weight:600;color:#2a2b2a!important;text-decoration:none!important}.mpom .om-dd-menu a:hover{background:#f5f6f8}.mpom .om-dd-menu small{font-weight:400;color:#5f6368;white-space:nowrap}\u003c\/style\u003e\u003cdiv class=\"mpom\"\u003e\n\u003cdiv class=\"om-head\"\u003e\n\u003cdiv\u003e\n\u003cspan class=\"om-tag\"\u003eINSTRUCTIONS\u003c\/span\u003e\u003cp class=\"om-lead\"\u003eCertification, components, installation loads and fasteners, post-installation and periodic testing, inspection and record keeping for the Ronstan RFC2433-09 removable screw-in padeye, a certified anchor device for personal fall protection.\u003c\/p\u003e\n\u003cdiv class=\"om-box\"\u003e\n\u003cdiv class=\"om-row\"\u003e\n\u003cspan\u003eDocument\u003c\/span\u003e\u003cb\u003eRonstan RFC2433-09 Removable Screw-In Padeye Anchor Device User Instructions\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-row\"\u003e\n\u003cspan\u003eFormat\u003c\/span\u003e\u003cb\u003ePDF · 11 pages · 1.0 MB\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-row\" style=\"border-bottom:0\"\u003e\n\u003cspan\u003eLanguage\u003c\/span\u003e\u003cb\u003eEnglish\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-acts\"\u003e\u003ca class=\"om-btn dl\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Ronstan-RFC2433-09-Removable-Screw-In-Padeye-Anchor-User-Manual.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003csvg viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2.4\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M12 4v11\"\u003e\u003c\/path\u003e\u003cpath d=\"m7 10 5 5 5-5\"\u003e\u003c\/path\u003e\u003cpath d=\"M5 20h14\"\u003e\u003c\/path\u003e\u003c\/svg\u003e Download PDF\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-toc\"\u003e\n\u003ca href=\"#om-system\"\u003eSystem\u003c\/a\u003e\u003ca href=\"#om-mounting\"\u003eMounting \u0026amp; Loads\u003c\/a\u003e\u003ca href=\"#om-install\"\u003eInstallation\u003c\/a\u003e\u003ca href=\"#om-testing\"\u003eTesting \u0026amp; Inspection\u003c\/a\u003e\u003ca href=\"#om-use\"\u003eUse \u0026amp; Records\u003c\/a\u003e\u003ca href=\"#om-products\"\u003eProducts\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-img\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Ronstan-RFC2433-09-Removable-Screw-In-Padeye-Anchor-User-Manual-Cover.png\" alt=\"Ronstan RFC2433-09 Removable Screw-In Padeye Anchor Device — User Instructions\" loading=\"lazy\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-system\"\u003e\n\u003ch2 class=\"om-h\"\u003eCertification \u0026amp; System\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCertified to European Standard EN795:2012, Type A (personal fall protection equipment – anchor devices), single person use only.\u003c\/li\u003e\n\u003cli\u003eCertified to Australian Standards AS1891.4:2009 and AS5532:2013 for single point anchorages, free fall-arrest, single person use only.\u003c\/li\u003e\n\u003cli\u003eFor attaching personal fall protection components (harnesses, lanyards, fall arresters) in accordance with EN363 and\/or AS1891.1 or AS1891.3, e.g. when working outside conventional guardrails for cleaning and maintenance. Not for lifting equipment or any other purpose.\u003c\/li\u003e\n\u003cli\u003eEach harness or device must be secured to a separate attachment point. In a fall arrest system the user must have a means of limiting the maximum dynamic force on the user to 6KN.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTwo parts\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eStructural anchor base (A)\u003c\/b\u003e: permanently fastened to the structure with 4 fasteners. A threaded plug stays in the base when the anchor is removed, keeping dirt and grit out of the threads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eScrew-in anchor (B)\u003c\/b\u003e: threads into the base on a central spigot; single U-piece attachment point for personal protection equipment; identification plate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eLocking screw (C)\u003c\/b\u003e: anti-rotation screw that must be engaged once the anchor is fully threaded in, so it cannot unintentionally detach.\u003c\/li\u003e\n\u003cli\u003eGrade 316 stainless steel base, anchor and locking screw.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"height:16px\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eRef.\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003eWeight (g)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eStructural Anchor Base\u003c\/td\u003e\n\u003ctd\u003e161\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eScrew-in Anchor\u003c\/td\u003e\n\u003ctd\u003e142\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eLocking Screw, M4x10 Hex CSK Head (SC4-410)\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enot shown\u003c\/td\u003e\n\u003ctd\u003eThreaded Plug (893217)\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Ronstan-RFC2433-09-Padeye-Anchor-Parts.png\" alt=\"Ronstan RFC2433-09 structural anchor base and screw-in anchor, dimensions in mm\" style=\"width:100%;height:auto;border:1px solid #e3e5e8;border-radius:6px;margin:0\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-mounting\"\u003e\n\u003ch2 class=\"om-h\"\u003eMounting Orientation \u0026amp; Design Loads\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThe base can be mounted in a vertical plane (0°), a horizontal plane (90°) or at any incline between 0° and 90° (deck, vertical or ceiling mounting).\u003c\/li\u003e\n\u003cli\u003eIdeally mount the screw-in anchor vertically for best lanyard alignment; load must be in line with the U-piece.\u003c\/li\u003e\n\u003cli\u003eMaximum loads transmitted from the anchor device to the structure, as shown in the manual: 12KN load at 16mm from the mounting face, giving a moment M=192Nm and a reaction of Fy=3KN in each fastener.\u003c\/li\u003e\n\u003cli\u003eThe structure holding the fasteners must be stiff enough that neither fastener nor structure fails at these loads; verify by calculation and post-installation testing at a minimum. Some jurisdictions require a pre-installation test on a prototype or mock-up.\u003c\/li\u003e\n\u003cli\u003eConsider galvanic compatibility between fastener and structure; isolation may be required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-install\"\u003e\n\u003ch2 class=\"om-h\"\u003eInstallation\u003c\/h2\u003e\n\u003cp class=\"om-note\"\u003eInstallation only by competent persons or organisations.\u003c\/p\u003e\n\u003ch3\u003eFasteners\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4 × M6 hexagon socket countersunk head, stainless steel A4-70 DIN7991 screws (not supplied), minimum tensile strength 700MPa.\u003c\/li\u003e\n\u003cli\u003eTorque no more than 7.1Nm, as per industry standard.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProcedure\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eThe device is supplied assembled with the locking screw in place. Mark the outer edge of the base with a pen to show the U-piece orientation when the anchor is fully threaded in.\u003c\/li\u003e\n\u003cli\u003eRemove the M4 locking screw with a 2.5mm hex key and unthread the anchor; the plastic plug stays in the base thread.\u003c\/li\u003e\n\u003cli\u003eUsing the base as a template, drill a clearance hole for the base spigot so the base sits flush with the mounting surface. For vertical mounting, put the pen mark at 12 o'clock so the U-piece runs 12 to 6 o'clock.\u003c\/li\u003e\n\u003cli\u003eCheck the locking screw can be fixed to the base with the U-piece in the right orientation.\u003c\/li\u003e\n\u003cli\u003eMark the 4 fastener holes using the base as a template and fix the base permanently.\u003c\/li\u003e\n\u003cli\u003eThread the anchor in, engaging the slot in the plastic plug when starting. When fully home, fit the locking screw with a drop of low strength thread lock; do not over-tighten (hex socket damage).\u003c\/li\u003e\n\u003cli\u003eIf the identification plate is not accessible and clearly visible after installation, add marking near the device.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block om-grid2\" id=\"om-testing\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eTesting\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003ePost-installation:\u003c\/b\u003e before first use, load each anchor with 6kN on the lanyard attachment point for a minimum of 15 seconds, then follow the annual inspection procedure. Record results in Appendix B (Equipment Record) and the Chief Installer's Installation Declaration (Appendix A).\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePeriodic:\u003c\/b\u003e same 6kN \/ 15 seconds test for each anchor; in the absence of other regulations, at intervals of not more than five years. Record results and follow the annual inspection.\u003c\/li\u003e\n\u003cli\u003eApply any standards or regulations for your jurisdiction, industry or application on top of this minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eInspection\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eBefore each use (user):\u003c\/b\u003e 4 base fasteners in place, fully tight and secure; anchor fully threaded home; locking screw secured; lanyard attachment point free from deformation (deformation means overload – replace); no excessive wear, corrosion, deformation or breakage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eAnnually (competent person):\u003c\/b\u003e the above, plus the male thread of the anchor may be lubricated with light grease; replace the locking screw if its thread is damaged or worn. Appendix C lists the full annual inspection and revision procedure, including checking the dust cover and lightly greasing the locking screw head before refitting with low strength thread lock.\u003c\/li\u003e\n\u003cli\u003eRemove from service if in doubt or if any part is damaged; no use until repaired and approved in writing by a competent person. After any fall, inspection and written confirmation are required before reuse.\u003c\/li\u003e\n\u003cli\u003eNo alterations without the manufacturer's prior written consent. Contact the manufacturer if the identification plate is missing or illegible.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-use\"\u003e\n\u003ch2 class=\"om-h\"\u003eUse, Maintenance \u0026amp; Records\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOnly trained, competent persons who have read the user manual may use the system; have a rescue plan in place.\u003c\/li\u003e\n\u003cli\u003eUse only with personal protective equipment approved to relevant standards. Never rely on only one attachment point.\u003c\/li\u003e\n\u003cli\u003eLoosen or remove the locking screw only for inspection and maintenance; it must be fully engaged (with a drop of low strength thread lock) whenever the anchor is in use.\u003c\/li\u003e\n\u003cli\u003eRinse all components regularly with fresh water.\u003c\/li\u003e\n\u003cli\u003eThe identification plate shows the standard (EN795:2012 Type A), part number and serial number; quote these in all communication with the manufacturer. Keep the installation documentation on site and give copies to the user.\u003c\/li\u003e\n\u003cli\u003eKeep a record for each anchor device: the PDF includes the Installation Plan and Declaration (Appendix A), the Equipment Record (Appendix B) and the Annual Inspection and Revision sheet (Appendix C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp class=\"om-note\"\u003eNeed a part that isn't listed? \u003ca href=\"\/pages\/contact\"\u003eAsk us to source it\u003c\/a\u003e and quote the part number from the PDF.\u003c\/p\u003e\n\u003ch2 class=\"om-h\" id=\"om-products\"\u003eProducts in this Manual\u003c\/h2\u003e\n\u003c\/div\u003e","products":[],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/collections\/Ronstan-RFC2433-09-Removable-Screw-In-Padeye-Anchor-User-Manual-Cover.png?v=1792712160","url":"https:\/\/www.mauripro.com\/collections\/owners-manuals-ronstan-rfc2433-09-removable-padeye-anchor.oembed","provider":"MAURIPRO Sailing","version":"1.0","type":"link"}