{"title":"Sleipner S-Link — Programming Manual \u0026 Alarm Codes","description":"\u003clink rel=\"stylesheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/om-manual-v2.css\"\u003e\u003cstyle\u003e.mpom .om-tbl.nw td+td{white-space:nowrap}.mpom details.om-dd{position:relative;margin:0}.mpom details.om-dd\u003esummary{list-style:none;cursor:pointer}.mpom details.om-dd\u003esummary::-webkit-details-marker{display:none}.mpom .om-dd-menu{position:absolute;left:0;top:calc(100% + 6px);min-width:100%;width:max-content;max-width:360px;background:#fff;border:1px solid #e3e5e8;border-radius:6px;box-shadow:0 8px 24px rgba(0,0,0,.14);z-index:30;padding:6px}.mpom .om-dd-menu a{display:flex;justify-content:space-between;align-items:center;gap:14px;padding:10px 12px;border-radius:4px;font-size:14px;font-weight:600;color:#2a2b2a!important;text-decoration:none!important}.mpom .om-dd-menu a:hover{background:#f5f6f8}.mpom .om-dd-menu small{font-weight:400;color:#5f6368;white-space:nowrap}\u003c\/style\u003e\u003cdiv class=\"mpom\"\u003e\n\u003cdiv class=\"om-head\"\u003e\n\u003cdiv\u003e\n\u003cspan class=\"om-tag\"\u003eSERVICE MANUAL\u003c\/span\u003e\u003cp class=\"om-lead\"\u003eUpgrade, diagnose and configure Sleipner S-Link products with S-Link Programmer and the 6 1307 firmware upgrade tool kit, and look up every S-Link alarm code with its cause and action – plus the legacy fault codes for older panels.\u003c\/p\u003e\n\u003cdiv class=\"om-box\"\u003e\n\u003cdiv class=\"om-row\"\u003e\n\u003cspan\u003eDocument\u003c\/span\u003e\u003cb\u003eSleipner S-Link Programming Manual \u0026amp; Alarm Codes\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-row\"\u003e\n\u003cspan\u003eFormat\u003c\/span\u003e\u003cb\u003ePDF · 16 pages · 1.2 MB\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-row\" style=\"border-bottom:0\"\u003e\n\u003cspan\u003eLanguage\u003c\/span\u003e\u003cb\u003eEnglish\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-acts\"\u003e\u003cdetails class=\"om-dd\"\u003e\u003csummary class=\"om-btn dl\"\u003e\u003csvg viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2.4\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M12 4v11\"\u003e\u003c\/path\u003e\u003cpath d=\"m7 10 5 5 5-5\"\u003e\u003c\/path\u003e\u003cpath d=\"M5 20h14\"\u003e\u003c\/path\u003e\u003c\/svg\u003e Download PDF ▾\u003c\/summary\u003e\u003cdiv class=\"om-dd-menu\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Sleipner-S-Link-Programmer-Manual-6-1307.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003eService Manual\u003c\/span\u003e\u003csmall\u003ePDF · 16 p.\u003c\/small\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Sleipner-S-Link-Alarm-Codes-Quick-Reference.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003eS-Link alarm codes – quick reference\u003c\/span\u003e\u003csmall\u003ePDF · 4 p.\u003c\/small\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Sleipner-Legacy-Fault-Codes.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003eLegacy fault codes (incl. MK steering and 8700 panel guides)\u003c\/span\u003e\u003csmall\u003ePDF · 8 p.\u003c\/small\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-toc\"\u003e\n\u003ca href=\"#om-setup\"\u003eSetup\u003c\/a\u003e\u003ca href=\"#om-fw\"\u003eFirmware\u003c\/a\u003e\u003ca href=\"#om-diag\"\u003eDiagnostics\u003c\/a\u003e\u003ca href=\"#om-alarms\"\u003eAlarm Codes\u003c\/a\u003e\u003ca href=\"#om-legacy\"\u003eLegacy Codes\u003c\/a\u003e\u003ca href=\"#om-products\"\u003eProducts\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-img\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Sleipner-S-Link-Programmer-Manual-6-1307-Cover.png\" alt=\"Sleipner S-Link — Programming Manual \u0026amp; Alarm Codes\" loading=\"lazy\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block om-grid2\" id=\"om-setup\"\u003e\n\u003ch2 class=\"om-h\"\u003eS-Link Programmer and Tool Kit 6 1307\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eInstall and Connect\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDownload the latest S-Link Programmer, unzip and run SLI.msi with administrator privileges, and follow the wizard. Requires Microsoft .NET V4.0 or newer; Windows 7, 8, 10, 11.\u003c\/li\u003e\n\u003cli\u003eThe Firmware Upgrade Tool Kit (order no. 6 1307) contains a USB to CAN dongle and cables to connect it to an S-Link BACKBONE cable (plug into a free T-connector).\u003c\/li\u003e\n\u003cli\u003ePower up all S-Link devices and the S-Link bus supply. An automatic main switch engages when S-Link Programmer is launched on a connected computer.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eAccess Levels\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDefault level: Firmware Upgrade, Device Control and Special Purpose Firmware.\u003c\/li\u003e\n\u003cli\u003eLogger, Fault Codes, CAN Capture, stored logs and Device Coding need a user key from your local Sleipner representative.\u003c\/li\u003e\n\u003cli\u003eMain view lists every connected product: name, location, product SNR, S-Link SNR, HW, FW, available FW, bootloader, update status and device config.\u003c\/li\u003e\n\u003cli\u003eWhile connected, the Programmer keeps telling Automatic Main Switches (AMS) to be ON; after Disconnect an AMS stays on only if a connected panel is ON.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-fw\"\u003e\n\u003ch2 class=\"om-h\"\u003eUpgrading Firmware\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCheck For Updates runs at launch and prompts when a newer image file is released; Download Updates loads the latest image file containing firmware for all S-Link products.\u003c\/li\u003e\n\u003cli\u003eUpgrade Device updates the selected product; Upgrade All Devices updates all in sequence, skipping products with special upgrade conditions or newer firmware.\u003c\/li\u003e\n\u003cli\u003eAlways verify: the revision in the FW column must not be lower than the Available FW column.\u003c\/li\u003e\n\u003cli\u003eOpen .sif File loads a special image (test or debugging); restart the Programmer or use File → Download Updates to return to released firmware.\u003c\/li\u003e\n\u003cli\u003eSpecial Purpose Firmware only on Sleipner's instructions: select a product, pick the version, click Use, then Upgrade Device. A reset button on the main view reverts to default firmware.\u003c\/li\u003e\n\u003cli\u003eDownload Manager fetches firmware for devices the Programmer cannot update (see that product's manual). Legacy products need Upgrade Bootloader for bootloader updates.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-diag\"\u003e\n\u003ch2 class=\"om-h\"\u003eLogger, Fault Codes and CAN Capture\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eS-Link Logger records selected parameters in real time (performance analysis, troubleshooting, commissioning tests); enter boat name and description, save as CSV or upload to Sleipner.\u003c\/li\u003e\n\u003cli\u003eFault Code Reader shows the stored fault history of the selected product with its parameters and counters; save as text, upload, or delete. Without GPS on the network the time stamp is missing.\u003c\/li\u003e\n\u003cli\u003eCAN Capture records raw CAN packets of the whole S-Link network for network diagnosis.\u003c\/li\u003e\n\u003cli\u003eDevice Coding changes the Coding parameter (e.g. electric vs hydraulic stabilizers); the device then enters bootloader mode and must be updated.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-alarms\"\u003e\n\u003ch2 class=\"om-h\"\u003eQuick Reference S-Link Alarm Codes\u003c\/h2\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eAlarm\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003eAction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eMotor Over-current\u003c\/td\u003e\n\u003ctd\u003eMotor current too high\u003c\/td\u003e\n\u003ctd\u003eThruster must be serviced by authorised personnel; reset or power OFF\/ON PPC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eMotor Over-temp\u003c\/td\u003e\n\u003ctd\u003eMotor temp has been over 120°C\/248°F (auto reset)\u003c\/td\u003e\n\u003ctd\u003eLet the motor cool below 110°C\/230°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eController Over-temp\u003c\/td\u003e\n\u003ctd\u003ePPC temp has been over 80°C\/176°F\u003c\/td\u003e\n\u003ctd\u003eLet the PPC cool below 45°C\/113°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eController Over-temp\u003c\/td\u003e\n\u003ctd\u003eSR150000 temp has been over 80°C\/176°F\u003c\/td\u003e\n\u003ctd\u003eLet the SR150000 cool below 45°C\/113°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eLow Voltage\u003c\/td\u003e\n\u003ctd\u003eLow motor voltage while running: 12V thruster below 8.00V, 24V thruster below 12.00V\u003c\/td\u003e\n\u003ctd\u003eRecharge battery; reset or power OFF\/ON\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003eThermoswitch\u003c\/td\u003e\n\u003ctd\u003eThermo switch input activated, open circuit\u003c\/td\u003e\n\u003ctd\u003eLet the thruster cool down before operating again\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003eIPC Error\u003c\/td\u003e\n\u003ctd\u003eMotor relay fault\u003c\/td\u003e\n\u003ctd\u003eTurn off the thruster battery main switch; service by authorised personnel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003eCritical Error\u003c\/td\u003e\n\u003ctd\u003ePPC output fail\u003c\/td\u003e\n\u003ctd\u003ePPC must be sent for service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003eLow Motor Current\u003c\/td\u003e\n\u003ctd\u003eThruster uses no power\u003c\/td\u003e\n\u003ctd\u003eCheck thruster connections, or motor dead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003eMotor Contact\u003c\/td\u003e\n\u003ctd\u003eNo current on motor relay coil\u003c\/td\u003e\n\u003ctd\u003eCheck motor relay connections, short circuit or relay dead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003eSystem Error\u003c\/td\u003e\n\u003ctd\u003eFatal error\u003c\/td\u003e\n\u003ctd\u003eDevice must be serviced by authorised personnel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003eNo Communication\u003c\/td\u003e\n\u003ctd\u003eNo communication with device\u003c\/td\u003e\n\u003ctd\u003eCheck S-Link cables and power connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003eMotor Temp Sensor\u003c\/td\u003e\n\u003ctd\u003eMotor temperature sensor fail\u003c\/td\u003e\n\u003ctd\u003eCheck for an open circuit on the motor temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003eSupply Voltage Fault\u003c\/td\u003e\n\u003ctd\u003eNo power\u003c\/td\u003e\n\u003ctd\u003eCheck power connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eFuse Blown\u003c\/td\u003e\n\u003ctd\u003eFuse blown\u003c\/td\u003e\n\u003ctd\u003eReplace fuse, or check whether the battery and thruster main cables have been swapped\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003eManual Override\u003c\/td\u003e\n\u003ctd\u003eMain switch manually overridden (auto reset)\u003c\/td\u003e\n\u003ctd\u003ePull the main switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003ctd\u003eMotion OUT Fault\u003c\/td\u003e\n\u003ctd\u003eRetract obstructed while deploying\u003c\/td\u003e\n\u003ctd\u003eTurn off all panels; go to lower speed \/ deeper water and retry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003eMotion IN Fault\u003c\/td\u003e\n\u003ctd\u003eRetract obstructed while retracting\u003c\/td\u003e\n\u003ctd\u003eTurn panel on and manually override main switch; remove obstruction and retry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003eActuator Fault\u003c\/td\u003e\n\u003ctd\u003eActuator not getting any power\u003c\/td\u003e\n\u003ctd\u003eCheck actuator connection\/power; reset alarm in the alarm menu on PJC 211\/212\/221\/222 or recycle power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003ePos.Sensor Fault\u003c\/td\u003e\n\u003ctd\u003eRetract position sensor fail\u003c\/td\u003e\n\u003ctd\u003eCheck position sensor cables and sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003ctd\u003eIn Service Mode\u003c\/td\u003e\n\u003ctd\u003eRetract controller in service mode (switch no. 4 ON)\u003c\/td\u003e\n\u003ctd\u003eCheck dip-switch setting on the retract control box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003eHigh Oil Temp\u003c\/td\u003e\n\u003ctd\u003eHydraulic oil above 75°C\/167°F\u003c\/td\u003e\n\u003ctd\u003eStop and let it cool; check the cooling pump runs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003ctd\u003eLow Oil Level\u003c\/td\u003e\n\u003ctd\u003eHydraulic oil level too low\u003c\/td\u003e\n\u003ctd\u003eTop up the hydraulic tank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003eWarning Return Filter\u003c\/td\u003e\n\u003ctd\u003eReturn filter element needs replacing\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003eWarning Pressure Filter\u003c\/td\u003e\n\u003ctd\u003ePressure filter element needs replacing\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003ctd\u003eWarning High Speed\u003c\/td\u003e\n\u003ctd\u003eHigh speed – stabilizer not active\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e27\u003c\/td\u003e\n\u003ctd\u003eStabilizer Fault\u003c\/td\u003e\n\u003ctd\u003eAny stabilizer alarm\u003c\/td\u003e\n\u003ctd\u003eSee the stabilizer panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003eAC Motor Over-temp\u003c\/td\u003e\n\u003ctd\u003eHydraulic AC motor power pack above 120°C\/248°F\u003c\/td\u003e\n\u003ctd\u003eStop and let it cool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e29\u003c\/td\u003e\n\u003ctd\u003eAC Motor Sensor Fail\u003c\/td\u003e\n\u003ctd\u003ePower pack temp sensor open circuit\u003c\/td\u003e\n\u003ctd\u003eCheck sensor cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003eTemperature Warning\u003c\/td\u003e\n\u003ctd\u003eMotor temperature getting high\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003ctd\u003eMotor Over-temp\u003c\/td\u003e\n\u003ctd\u003eHigh temperature alarm\u003c\/td\u003e\n\u003ctd\u003eSee the SAC manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003eVFD Warning\u003c\/td\u003e\n\u003ctd\u003eWarning from the VFD\u003c\/td\u003e\n\u003ctd\u003eCheck the VFD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003ctd\u003eVFD Not Ready\u003c\/td\u003e\n\u003ctd\u003eVFD not ready\u003c\/td\u003e\n\u003ctd\u003eCheck the VFD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003ctd\u003eVFD Fault\u003c\/td\u003e\n\u003ctd\u003eVFD has an alarm\u003c\/td\u003e\n\u003ctd\u003eCheck the VFD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003eWarning Low Voltage\u003c\/td\u003e\n\u003ctd\u003eLow motor voltage warning while running: 12V below 9.30V, 24V below 17.50V\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003ctd\u003eNot Calibrated\u003c\/td\u003e\n\u003ctd\u003eShaft not calibrated\u003c\/td\u003e\n\u003ctd\u003eSee the manual for calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003eVFD Com. Fault\u003c\/td\u003e\n\u003ctd\u003eNo Modbus communication with VFD\u003c\/td\u003e\n\u003ctd\u003eCheck VFD Modbus cables and power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e38\u003c\/td\u003e\n\u003ctd\u003eCooling Fan Fault\u003c\/td\u003e\n\u003ctd\u003eCooling fan stopped or running too slow\u003c\/td\u003e\n\u003ctd\u003eDevice must be sent for service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e39\u003c\/td\u003e\n\u003ctd\u003eInterlock\u003c\/td\u003e\n\u003ctd\u003eS-Link communication between PPC and retract controller missing\u003c\/td\u003e\n\u003ctd\u003eCheck power and S-Link to PPC and retract controller; check PPC or SR150000\/SR61242 is not wrongly set up as SRP or SRVP\/SRLP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp class=\"om-note\"\u003ePPC = PPC520, PPC820, PPC840 and PPC800. The external buzzer is only activated when a thruster device is operated (sending thrust on S-Link). Read the relevant manual before troubleshooting, or consult a professional.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-legacy\"\u003e\n\u003ch2 class=\"om-h\"\u003eLegacy Fault Codes (Older Products)\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThe same generic codes 1–39 are used on old products and products with old firmware.\u003c\/li\u003e\n\u003cli\u003eThe legacy document also holds the MK1\/MK2\/MK3 power steering troubleshooting guide (e.g. valve coil resistance 39,3Ω and servo valve coil 21,7Ω @20°C, low voltage alarm below 18V) and the 8700 retract panel flash-code guide.\u003c\/li\u003e\n\u003cli\u003e8700 panel examples: 1 flash yellow \u0026amp; green = thruster overtemp (retracts; turn off panel, wait 20 min); 3 flash yellow \u0026amp; red = retract obstructed (retries 3 times); 2 flash yellow, green \u0026amp; red = AMS fuse blown.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"om-note\"\u003eAfter an IPC error turn the main switch off immediately to stop the thruster main relays overheating. A retractable thruster will not retract while reversing at high speed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp class=\"om-note\"\u003eNeed a part that isn't listed? \u003ca href=\"\/pages\/contact\"\u003eAsk us to source it\u003c\/a\u003e and quote the part number from the PDF.\u003c\/p\u003e\n\u003ch2 class=\"om-h\" id=\"om-products\"\u003eProducts in this Manual\u003c\/h2\u003e\n\u003c\/div\u003e","products":[],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/collections\/Sleipner-S-Link-Programmer-Manual-6-1307-Cover.png?v=1793122244","url":"https:\/\/www.mauripro.com\/collections\/owners-manuals-sleipner-s-link-programming-alarm-codes.oembed","provider":"MAURIPRO Sailing","version":"1.0","type":"link"}