{"title":"Sleipner Thruster Monitoring Unit TMU-1 — Installation \u0026 User Manual","description":"\u003clink rel=\"stylesheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/om-manual-v2.css\"\u003e\u003cstyle\u003e.mpom .om-tbl.nw td+td{white-space:nowrap}.mpom details.om-dd{position:relative;margin:0}.mpom details.om-dd\u003esummary{list-style:none;cursor:pointer}.mpom details.om-dd\u003esummary::-webkit-details-marker{display:none}.mpom .om-dd-menu{position:absolute;left:0;top:calc(100% + 6px);min-width:100%;width:max-content;max-width:360px;background:#fff;border:1px solid #e3e5e8;border-radius:6px;box-shadow:0 8px 24px rgba(0,0,0,.14);z-index:30;padding:6px}.mpom .om-dd-menu a{display:flex;justify-content:space-between;align-items:center;gap:14px;padding:10px 12px;border-radius:4px;font-size:14px;font-weight:600;color:#2a2b2a!important;text-decoration:none!important}.mpom .om-dd-menu a:hover{background:#f5f6f8}.mpom .om-dd-menu small{font-weight:400;color:#5f6368;white-space:nowrap}\u003c\/style\u003e\u003cdiv class=\"mpom\"\u003e\n\u003cdiv class=\"om-head\"\u003e\n\u003cdiv\u003e\n\u003cspan class=\"om-tag\"\u003eOWNER'S MANUAL\u003c\/span\u003e\u003cp class=\"om-lead\"\u003ePut thruster motor RPM and the gearleg low-oil alarm on your S-Link bus with the Sleipner TMU-1: variants, specifications, configuration (location, sensors, pulses per revolution) and installation.\u003c\/p\u003e\n\u003cdiv class=\"om-box\"\u003e\n\u003cdiv class=\"om-row\"\u003e\n\u003cspan\u003eDocument\u003c\/span\u003e\u003cb\u003eSleipner Thruster Monitoring Unit TMU-1 Installation \u0026amp; User Manual\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-row\"\u003e\n\u003cspan\u003eFormat\u003c\/span\u003e\u003cb\u003ePDF · 12 pages · 1.0 MB\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-row\" style=\"border-bottom:0\"\u003e\n\u003cspan\u003eLanguage\u003c\/span\u003e\u003cb\u003eEnglish\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-acts\"\u003e\u003ca class=\"om-btn dl\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Sleipner-TMU-1-Thruster-Monitoring-Unit-Installation-User-Manual.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003csvg viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2.4\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M12 4v11\"\u003e\u003c\/path\u003e\u003cpath d=\"m7 10 5 5 5-5\"\u003e\u003c\/path\u003e\u003cpath d=\"M5 20h14\"\u003e\u003c\/path\u003e\u003c\/svg\u003e Download PDF\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-toc\"\u003e\n\u003ca href=\"#om-specs\"\u003eSpecifications\u003c\/a\u003e\u003ca href=\"#om-config\"\u003eConfiguration\u003c\/a\u003e\u003ca href=\"#om-install\"\u003eInstallation\u003c\/a\u003e\u003ca href=\"#om-slink\"\u003eS-Link Bus\u003c\/a\u003e\u003ca href=\"#om-products\"\u003eProducts\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-img\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Sleipner-TMU-1-Thruster-Monitoring-Unit-Installation-User-Manual-Cover.png\" alt=\"Sleipner Thruster Monitoring Unit TMU-1 — Installation \u0026amp; User Manual\" loading=\"lazy\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block om-grid2\" id=\"om-specs\"\u003e\n\u003ch2 class=\"om-h\"\u003eTMU-1 at a Glance\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eVariants\u003c\/h2\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003cth\u003eOil level sensor cable\u003c\/th\u003e\n\u003cth\u003eRPM sensor cable\u003c\/th\u003e\n\u003cth\u003eComment\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTMU-1-SAC\u003c\/td\u003e\n\u003ctd\u003eCable length 5m\u003c\/td\u003e\n\u003ctd\u003eCable length 5m\u003c\/td\u003e\n\u003ctd\u003eM23 connector, for AC thrusters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTMU-1-SH\u003c\/td\u003e\n\u003ctd\u003eCable length 5m\u003c\/td\u003e\n\u003ctd\u003eCable length 5m\u003c\/td\u003e\n\u003ctd\u003eDeutsch DT connector, for hydraulic motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eRequires a thruster motor with RPM sensor and a Sleipner oil tank kit that supports TMU-1.\u003c\/li\u003e\n\u003cli\u003eS-Link status LED: green = connection OK; blinking = not connected.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eTechnical Specification\u003c\/h2\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003eMin 9VDC \/ typical 12V\/24V \/ max 31VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated max input power\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e150g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e121x96x43mm (WxLxH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-config\"\u003e\n\u003ch2 class=\"om-h\"\u003eConfiguring TMU-1\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLocation (default Bow): Bow (or port bow of two), Stern (or port stern of two), Bow Starboard, Stern Starboard – match the thruster it is wired to.\u003c\/li\u003e\n\u003cli\u003eOil Level Sensor (default Enable): the oil tank level switch is normally closed and opens when the level drops; Enable makes TMU-1 raise an alarm when it opens.\u003c\/li\u003e\n\u003cli\u003eSpeed Sensor (default Enable): reports measured RPM on S-Link for panels or a Voyage Data Recorder.\u003c\/li\u003e\n\u003cli\u003eSpeed Sensor Resolution: pulses per revolution, 1 to 5000 (default 1024, typical for AC thrusters).\u003c\/li\u003e\n\u003cli\u003eSpeed Sensor Direction (default Normal): use Swapped if starboard does not read positive RPM and port negative.\u003c\/li\u003e\n\u003cli\u003eConfigure from a PJC4xx panel (see its user manual).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eThruster model\u003c\/th\u003e\n\u003cth\u003ePulses per revolution\u003c\/th\u003e\n\u003cth\u003eMotor brand\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSHx\/x-BA32-S\u003c\/td\u003e\n\u003ctd\u003e38\u003c\/td\u003e\n\u003ctd\u003eRexroth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSHx\/x-BA40-S\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003eParker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSHx\/x-BA45-S\u003c\/td\u003e\n\u003ctd\u003e47\u003c\/td\u003e\n\u003ctd\u003eRexroth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSHx\/x-BA56-S\u003c\/td\u003e\n\u003ctd\u003e47\u003c\/td\u003e\n\u003ctd\u003eRexroth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSHx\/x-BA60-S\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003eParker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSHx\/x-BA80-S\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003eParker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSHx\/x-BA90-S\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003eParker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSHx\/x-BA110-S\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003eParker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSHx\/x-BA125-S\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003eParker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSHx\/x-BA150-S\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003eParker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSHx\/x-BA160-S\u003c\/td\u003e\n\u003ctd\u003e67\u003c\/td\u003e\n\u003ctd\u003eRexroth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSHx\/x-BA180-S\u003c\/td\u003e\n\u003ctd\u003e67\u003c\/td\u003e\n\u003ctd\u003eRexroth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSACx\/x-x-x-x\u003c\/td\u003e\n\u003ctd\u003e1024\u003c\/td\u003e\n\u003ctd\u003eSleipner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-install\"\u003e\n\u003ch2 class=\"om-h\"\u003eInstalling TMU-1\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eScrew the box to a solid surface.\u003c\/li\u003e\n\u003cli\u003eConnect an S-Link SPUR Cable between TMU-1 and a T-connector on the S-Link BACKBONE Cable.\u003c\/li\u003e\n\u003cli\u003eConnect the RPM Sensor Cable between TMU-1 and the RPM sensor on the motor (AC motor or hydraulic motor).\u003c\/li\u003e\n\u003cli\u003eConnect the Oil Level Sensor Cable between TMU-1 and the oil tank.\u003c\/li\u003e\n\u003cli\u003eConfigure TMU-1 (PJC4xx user manual).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"om-note\"\u003eFault codes are broadcast on S-Link and shown on your S-Link control panel; Sleipner's Fault Code Navigator explains each code.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block om-grid2\" id=\"om-slink\"\u003e\n\u003ch2 class=\"om-h\"\u003eS-Link System Rules\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eCables \u0026amp; Connectors\u003c\/h2\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eRole\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBACKBONE Cable (blue ends)\u003c\/td\u003e\n\u003ctd\u003eCommon power and communication bus through the vessel; standard lengths\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSPUR Cable (green ends)\u003c\/td\u003e\n\u003ctd\u003eOne per connected product, no exceptions; keep as short as practical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePOWER Cable\u003c\/td\u003e\n\u003ctd\u003eRequired in every installation; only one per BACKBONE; protect with a 2A fuse. Yellow and black wires to GND, red to +12VDC or +24VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT-Connector\u003c\/td\u003e\n\u003ctd\u003eOne per SPUR or POWER Cable on the BACKBONE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4-Port T-Connector\u003c\/td\u003e\n\u003ctd\u003eSeveral SPUR Cables on one point; two sealing caps for unused ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBACKBONE Extender\u003c\/td\u003e\n\u003ctd\u003eJoins two BACKBONE Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEND Terminator\u003c\/td\u003e\n\u003ctd\u003eOne at each end of the BACKBONE bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eInstallation Rules\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eKeep BACKBONE and SPUR lengths to a minimum; consult your distributor if the total BACKBONE exceeds 100 meters.\u003c\/li\u003e\n\u003cli\u003eFasten cables to avoid sharp bends, chafe and strain on connectors; close the connector locks fully.\u003c\/li\u003e\n\u003cli\u003eDo not leave cables, T-Connectors or Extenders permanently immersed; make a U-bend before each product connector so water does not run into it.\u003c\/li\u003e\n\u003cli\u003eIdeally connect the POWER Cable in the middle of the BACKBONE for equal voltage drop at both ends.\u003c\/li\u003e\n\u003cli\u003eRoute S-Link away from radio transmitters, antennas and high voltage cables.\u003c\/li\u003e\n\u003cli\u003eUnused SPUR cables may be left unterminated for future equipment: protect the open connectors from water.\u003c\/li\u003e\n\u003cli\u003eConnect only original Sleipner S-Link products or authorised equipment directly to the bus; third-party equipment goes through a Sleipner interface, and at least one original Sleipner control panel must still be installed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"om-note\"\u003eNeed a part that isn't listed? \u003ca href=\"\/pages\/contact\"\u003eAsk us to source it\u003c\/a\u003e and quote the part number from the PDF.\u003c\/p\u003e\n\u003ch2 class=\"om-h\" id=\"om-products\"\u003eProducts in this Manual\u003c\/h2\u003e\n\u003c\/div\u003e","products":[{"product_id":"sidsm61327","title":"Side-Power (Sleipner) S-Link Terminator for Backbone","description":"\u003cp\u003eS-Link Terminator for Backbone.\u003c\/p\u003e\u003cp\u003eOur Part # SIDSM61327 | Side-Power (Sleipner) Part # SM61327\u003c\/p\u003e","brand":"Sleipner","offers":[{"title":"Default Title","offer_id":49347549266226,"sku":"SIDSM61327","price":39.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/SIDSM61327.jpg?v=1728037531"},{"product_id":"sidsm61322","title":"Side-Power (Sleipner) S-Link Backbone Extender","description":"\u003cp\u003eS-Link Backbone Extender.\u003c\/p\u003e\u003cp\u003eOur Part # SIDSM61322 | Side-Power (Sleipner) Part # SM61322\u003c\/p\u003e","brand":"Sleipner","offers":[{"title":"Default Title","offer_id":49347581051186,"sku":"SIDSM61322","price":47.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/SIDSM61322.jpg?v=1728030704"},{"product_id":"sidsm61328","title":"Side-Power (Sleipner) S-Link Spur Power Cable - 2.5m","description":"\u003cp\u003eS-Link Spur Power Cable, 2.5m (8.2 ft).\u003c\/p\u003e\u003cp\u003eOur Part # SIDSM61328 | Side-Power (Sleipner) Part # SM61328\u003c\/p\u003e","brand":"Sleipner","offers":[{"title":"Default Title","offer_id":49347597238578,"sku":"SIDSM61328","price":51.47,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/SIDSM61328.jpg?v=1728040913"},{"product_id":"sidsm61326","title":"Side-Power (Sleipner) S-Link T Connector to Spur","description":"\u003cp\u003eS-Link T Connector to Spur.\u003c\/p\u003e\u003cp\u003eOur Part # SIDSM61326 | Side-Power (Sleipner) Part # SM61326\u003c\/p\u003e","brand":"Sleipner","offers":[{"title":"Default Title","offer_id":49347598844210,"sku":"SIDSM61326","price":53.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/SIDSM61326.jpg?v=1728033678"},{"product_id":"sidsm6132104m","title":"Side-Power (Sleipner) S-Link Cable Spur","description":"\u003cp\u003eS-Link Cable Spur, 0.4M (1.31 ft).\u003c\/p\u003e\u003cp\u003eOur Part # SIDSM6132104M | Side-Power (Sleipner) Part # SM61321-0.4M\u003c\/p\u003e","brand":"Sleipner","offers":[{"title":"Default Title","offer_id":49347643015474,"sku":"SIDSM6132104M","price":68.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/SIDSM6132104M.jpg?v=1728022524"},{"product_id":"sidsm6132002m","title":"Side-Power (Sleipner) S-Link Cable Backbone","description":"\u003cp\u003eS-Link Cable Backbone, 0.2M (7.87 in).\u003c\/p\u003e\u003cp\u003eOur Part # SIDSM6132002M | Side-Power (Sleipner) Part # SM61320-0.2M\u003c\/p\u003e","brand":"Sleipner","offers":[{"title":"Default Title","offer_id":49347645833522,"sku":"SIDSM6132002M","price":68.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/SIDSM6132002M.jpg?v=1728043966"},{"product_id":"sidsm613211m","title":"Side-Power (Sleipner) Cable Spur S-Link, 1m (3')","description":"\u003cp\u003eS-link is a CAN-based control system with full intelligent communication between all units in the system, much like a computer network.\u003c\/p\u003e\u003cp\u003eOur Part # SIDSM613211M | Side-Power (Sleipner) Part # SM61321-1M\u003c\/p\u003e","brand":"Sleipner","offers":[{"title":"Default Title","offer_id":49347653632306,"sku":"SIDSM613211M","price":74.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/SIDSM613211M.jpg?v=1728049139"},{"product_id":"sidsm613202m","title":"Side-Power (Sleipner) Cable backbone S-Link, 2m (6.5')","description":"\u003cp\u003eS-link is a CAN-based control system with full intelligent communication between all units in the system, much like a computer network.\u003c\/p\u003e\u003cp\u003eOur Part # SIDSM613202M | Side-Power (Sleipner) Part # SM61320-2M\u003c\/p\u003e","brand":"Sleipner","offers":[{"title":"Default Title","offer_id":49347695771954,"sku":"SIDSM613202M","price":82.12,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/SIDSM613202M.jpg?v=1728053428"},{"product_id":"sidsm613213m","title":"Side-Power (Sleipner) Cable Spur S-Link, 3m (10')","description":"\u003cp\u003eS-link is a CAN-based control system with full intelligent communication between all units in the system, much like a computer network.\u003c\/p\u003e\u003cp\u003eOur Part # SIDSM613213M | Side-Power (Sleipner) Part # SM61321-3M\u003c\/p\u003e","brand":"Sleipner","offers":[{"title":"Default Title","offer_id":49347726115122,"sku":"SIDSM613213M","price":92.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/SIDSM613213M.jpg?v=1728062047"},{"product_id":"sidsm613204m","title":"Side-Power (Sleipner) Cable backbone S-Link, 4m (13')","description":"\u003cp\u003eS-link is a CAN-based control system with full intelligent communication between all units in the system, much like a computer network.\u003c\/p\u003e\u003cp\u003eOur Part # SIDSM613204M | Side-Power (Sleipner) Part # SM61320-4M\u003c\/p\u003e","brand":"Sleipner","offers":[{"title":"Default Title","offer_id":49347745415474,"sku":"SIDSM613204M","price":102.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/SIDSM613204M.jpg?v=1728064562"},{"product_id":"sidsm613215m","title":"Side-Power (Sleipner) Cable Spur S-Link, 5m (16')","description":"\u003cp\u003eS-link is a CAN-based control system with full intelligent communication between all units in the system, much like a computer network.\u003c\/p\u003e\u003cp\u003eOur Part # SIDSM613215M | Side-Power (Sleipner) Part # SM61321-5M\u003c\/p\u003e","brand":"Sleipner","offers":[{"title":"Default Title","offer_id":49347768156466,"sku":"SIDSM613215M","price":111.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/SIDSM613215M.jpg?v=1728020805"},{"product_id":"sidsm613207m","title":"Side-Power (Sleipner) Cable backbone S-Link, 7m (23')","description":"\u003cp\u003eS-link is a CAN-based control system with full intelligent communication between all units in the system, much like a computer network.\u003c\/p\u003e\u003cp\u003eOur Part # SIDSM613207M | Side-Power (Sleipner) Part # SM61320-7M\u003c\/p\u003e","brand":"Sleipner","offers":[{"title":"Default Title","offer_id":49347810263346,"sku":"SIDSM613207M","price":131.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/SIDSM613207M.jpg?v=1728027585"},{"product_id":"sidsm6132010m","title":"Side-Power (Sleipner) Cable backbone S-Link, 10m (33')","description":"\u003cp\u003eS-link is a CAN-based control system with full intelligent communication between all units in the system, much like a computer network.\u003c\/p\u003e\u003cp\u003eOur Part # SIDSM6132010M | Side-Power (Sleipner) Part # SM61320-10M\u003c\/p\u003e","brand":"Sleipner","offers":[{"title":"Default Title","offer_id":49347887038770,"sku":"SIDSM6132010M","price":165.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/SIDSM6132010M.jpg?v=1728035000"},{"product_id":"sidsm6132015m","title":"Side-Power (Sleipner) Cable backbone S-Link, 15m (49')","description":"\u003cp\u003eS-link is a CAN-based control system with full intelligent communication between all units in the system, much like a computer network.\u003c\/p\u003e\u003cp\u003eOur Part # SIDSM6132015M | Side-Power (Sleipner) Part # SM61320-15M\u003c\/p\u003e","brand":"Sleipner","offers":[{"title":"Default Title","offer_id":49347982164274,"sku":"SIDSM6132015M","price":208.12,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/SIDSM6132015M.jpg?v=1728021185"},{"product_id":"sidsm6132020m","title":"Side-Power (Sleipner) Cable backbone S-Link, 20m (66')","description":"\u003cp\u003eS-link is a CAN-based control system with full intelligent communication between all units in the system, much like a computer network.\u003c\/p\u003e\u003cp\u003eOur Part # SIDSM6132020M | Side-Power (Sleipner) Part # SM61320-20M\u003c\/p\u003e","brand":"Sleipner","offers":[{"title":"Default Title","offer_id":49348060873010,"sku":"SIDSM6132020M","price":268.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/SIDSM6132020M.jpg?v=1728044659"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/collections\/Sleipner-TMU-1-Thruster-Monitoring-Unit-Installation-User-Manual-Cover.png?v=1793122627","url":"https:\/\/www.mauripro.com\/collections\/owners-manuals-sleipner-thruster-monitoring-unit-tmu-1.oembed","provider":"MAURIPRO Sailing","version":"1.0","type":"link"}