{"title":"Vetus BOWPRO Push-Button Control Interface CANVXCSP — Installation Manual","description":"\u003clink rel=\"stylesheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/om-manual-v2.css\"\u003e\u003cstyle\u003e.mpom .om-tbl.nw td+td{white-space:nowrap}.mpom details.om-dd{position:relative;margin:0}.mpom details.om-dd\u003esummary{list-style:none;cursor:pointer}.mpom details.om-dd\u003esummary::-webkit-details-marker{display:none}.mpom .om-dd-menu{position:absolute;left:0;top:calc(100% + 6px);min-width:100%;width:max-content;max-width:360px;background:#fff;border:1px solid #e3e5e8;border-radius:6px;box-shadow:0 8px 24px rgba(0,0,0,.14);z-index:30;padding:6px}.mpom .om-dd-menu a{display:flex;justify-content:space-between;align-items:center;gap:14px;padding:10px 12px;border-radius:4px;font-size:14px;font-weight:600;color:#2a2b2a!important;text-decoration:none!important}.mpom .om-dd-menu a:hover{background:#f5f6f8}.mpom .om-dd-menu small{font-weight:400;color:#5f6368;white-space:nowrap}\u003c\/style\u003e\u003cdiv class=\"mpom\"\u003e\n\u003cdiv class=\"om-head\"\u003e\n\u003cdiv\u003e\n\u003cspan class=\"om-tag\"\u003eINSTALLATION MANUAL\u003c\/span\u003e\u003cp class=\"om-lead\"\u003eWiring of push buttons and status LEDs, switch-on, group codes, factory reset, LED meanings and CAN-bus fault finding for the Vetus CANVXCSP interface that lets momentary push buttons (e.g. on an engine control lever) run a BOWPRO thruster at full thrust.\u003c\/p\u003e\n\u003cdiv class=\"om-box\"\u003e\n\u003cdiv class=\"om-row\"\u003e\n\u003cspan\u003eDocument\u003c\/span\u003e\u003cb\u003eVetus BOWPRO Push-Button Control Interface CANVXCSP Installation Manual\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-row\"\u003e\n\u003cspan\u003eFormat\u003c\/span\u003e\u003cb\u003ePDF · 52 pages · 7.6 MB\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-row\" style=\"border-bottom:0\"\u003e\n\u003cspan\u003eLanguage\u003c\/span\u003e\u003cb\u003eEnglish\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-acts\"\u003e\n\u003ca class=\"om-btn dl\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Vetus-CANVXCSP-BOWPRO-Push-Button-Control-Interface-Installation-Manual.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003csvg viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2.4\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M12 4v11\"\u003e\u003c\/path\u003e\u003cpath d=\"m7 10 5 5 5-5\"\u003e\u003c\/path\u003e\u003cpath d=\"M5 20h14\"\u003e\u003c\/path\u003e\u003c\/svg\u003e Download PDF\u003c\/a\u003e\u003ca class=\"om-btn buy\" href=\"\/products\/vtscanvxcsp\"\u003eBuy\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-toc\"\u003e\n\u003ca href=\"#om-install\"\u003eInstallation\u003c\/a\u003e\u003ca href=\"#om-use\"\u003eOperation\u003c\/a\u003e\u003ca href=\"#om-errors\"\u003eSignals \u0026amp; Faults\u003c\/a\u003e\u003ca href=\"#om-products\"\u003eProducts\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-img\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Vetus-CANVXCSP-BOWPRO-Push-Button-Control-Interface-Installation-Manual-Cover.png\" alt=\"Vetus BOWPRO Push-Button Control Interface CANVXCSP — Installation Manual\" loading=\"lazy\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block om-grid2\" id=\"om-install\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eButtons and LEDs\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePush buttons: momentary, normally open (NO); pressing a button gives maximum thrust. LEDs: 5 V, 40 mA (max).\u003c\/li\u003e\n\u003cli\u003eMount the interface out of sight in a ventilated place.\u003c\/li\u003e\n\u003cli\u003eThe supplied harness serves a bow thruster (wires to pins 1, 2, 3, 10, 11, 12, 13 and 14):\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eCable label\u003c\/th\u003e\n\u003cth\u003ePins \/ colours\u003c\/th\u003e\n\u003cth\u003eConnects\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBOW PB-1\u003c\/td\u003e\n\u003ctd\u003e2 (brown), 10 (white)\u003c\/td\u003e\n\u003ctd\u003eButton 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBOW PB-2\u003c\/td\u003e\n\u003ctd\u003e3 (yellow), 11 (green)\u003c\/td\u003e\n\u003ctd\u003eButton 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBLUE LED\u003c\/td\u003e\n\u003ctd\u003e1 (–, grey), 13 (+, pink)\u003c\/td\u003e\n\u003ctd\u003eBlue status LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRED LED\u003c\/td\u003e\n\u003ctd\u003e12 (–, red), 14 (+, blue)\u003c\/td\u003e\n\u003ctd\u003eRed error\/warning LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eStern thruster: make up a 4-core cable with 4 connection pins AT62-201-16141-22, remove the white pins from positions 6, 7, 8 and 9 and insert the wires: pins 6 and 8 for STERN PB-1, pins 7 and 9 for STERN PB-2.\u003c\/li\u003e\n\u003cli\u003eWrong thrust direction for a button: swap the wiring of PB-1 and PB-2.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eCAN Bus\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eConnect the V-CAN cables as the example diagram: CAN-bus supply, terminators at both ends, connection box of the thruster.\u003c\/li\u003e\n\u003cli\u003eComponents with one connection (B) join the network through a hub; components with two connections (A) can simply be interconnected. Place the 12 Volt CAN-bus supply preferably in the middle of the system.\u003c\/li\u003e\n\u003cli\u003eThe CAN-bus power supply must always be 12 Volt (≥10 V, ≤16 V).\u003c\/li\u003e\n\u003cli\u003eWith a DC\/DC converter feeding the CAN bus, make sure input and output minus terminals are, or can be, jumpered.\u003c\/li\u003e\n\u003cli\u003eSee the bow or stern thruster manual for the detailed thruster CAN-bus diagram and configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block om-grid2\" id=\"om-use\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eOn, Off, Takeover\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOn: press BOW PB-1 and BOW PB-2 together; the blue LED flashes with a repeating di-di-di; press both again within 6 seconds – blue LED steady and dah-di-dah (- . -) = ready.\u003c\/li\u003e\n\u003cli\u003eA second, inactive panel shows a heartbeat (two short blue flashes every second). Take over control with the same switch-on procedure.\u003c\/li\u003e\n\u003cli\u003eOff: hold both bow buttons until all LEDs are off and the switch-off signal sounds; switch off the battery master switch when leaving.\u003c\/li\u003e\n\u003cli\u003eCheck the thrust direction of every button on every panel, carefully and in a safe place.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"om-h\"\u003eGroup Codes and Reset\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUp to four panels (group A–D). Switch off, wait 5 s, hold both bow buttons 10 s, release, press both twice (di-dah-di): configuration mode.\u003c\/li\u003e\n\u003cli\u003eShort-press PB-1 or PB-2 to step through the groups: A blue flashing; B red flashing; C blue and red alternately; D blue and red together. Press both once to confirm.\u003c\/li\u003e\n\u003cli\u003eFactory reset: switch off, hold both bow buttons 30 s (red LED flashes after 15 s, blue LED on after 30 s), release, press both once to confirm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-errors\"\u003e\n\u003ch2 class=\"om-h\"\u003eLED \/ Buzzer Messages\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003eMessages for bow and stern thruster separately: is \/ was overheated, is \/ was overloaded, is \/ was limiting, supply low; plus child lock after the first push, device enabled and ready, device inactive with thruster active, and disconnected from the network. The blue\/red LED and buzzer pattern for each is in the table in the PDF.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp class=\"om-note\"\u003eNeed a part that isn't listed? \u003ca href=\"\/pages\/contact\"\u003eAsk us to source it\u003c\/a\u003e and quote the part number from the PDF.\u003c\/p\u003e\n\u003ch2 class=\"om-h\" id=\"om-products\"\u003eProducts in this Manual\u003c\/h2\u003e\n\u003c\/div\u003e","products":[{"product_id":"vtscanvxcsp","title":"Vetus Prop. thruster on\/off switch interface","description":"\u003cp\u003eSimplify your boat's thruster operation with the reliable \u003cb\u003eVetus Prop. thruster on\/off switch interface\u003c\/b\u003e. This straightforward interface provides basic, dependable activation for your proportional thrusters, offering essential control with ease.\u003c\/p\u003e","brand":"Vetus","offers":[{"title":"Default Title","offer_id":50893129875762,"sku":"VTSCANVXCSP","price":833.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/CANVXCSP_1fe1eaf7-ad0c-4687-ad3e-03c743dbbd20.jpg?v=1771633609"},{"product_id":"vtscanvt","title":"Vetus CAN terminating resistor v2","description":"\u003cp\u003eOptimize your CAN-bus network's performance with the enhanced \u003cb\u003eVetus CAN terminating resistor v2\u003c\/b\u003e. This crucial component ensures proper signal termination at the end of your CAN-bus line, preventing data reflection and maintaining signal integrity. Rely on its stable operation for dependable communication across your marine systems.\u003c\/p\u003e","brand":"Vetus","offers":[{"title":"Default Title","offer_id":50893131022642,"sku":"VTSCANVT","price":84.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/VETUS-Genuine-Parts_af7a6544-fc50-46f3-8c85-ead7a7bd9937.png?v=1773081699"},{"product_id":"vtscanvhub","title":"Vetus V-CAN 3 point Y hub","description":"\u003cp\u003eOrganize and expand your Vetus V-CAN network with ease using the \u003cb\u003eVetus V-CAN 3 point Y hub\u003c\/b\u003e. This versatile hub provides three connection points, making it simple to branch out and integrate multiple V-CAN compatible devices into your marine electrical system. Enjoy a cleaner installation and robust data transfer for your essential onboard equipment.\u003c\/p\u003e","brand":"Vetus","offers":[{"title":"Default Title","offer_id":50893131710770,"sku":"VTSCANVHUB","price":85.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/VETUS-Genuine-Parts_2f72bb4f-1911-4bac-bdf1-089e2406fb77.png?v=1773081699"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/collections\/Vetus-CANVXCSP-BOWPRO-Push-Button-Control-Interface-Installation-Manual-Cover.png?v=1793028990","url":"https:\/\/www.mauripro.com\/collections\/owners-manuals-vetus-bowpro-push-button-interface-canvxcsp.oembed","provider":"MAURIPRO Sailing","version":"1.0","type":"link"}