{"title":"Wichard Anti-Torque Cable Clamps — Installation Guide","description":"\u003clink rel=\"stylesheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/om-manual-v2.css\"\u003e\u003cstyle\u003e.mpom .om-tbl.nw td+td{white-space:nowrap}.mpom details.om-dd{position:relative;margin:0}.mpom details.om-dd\u003esummary{list-style:none;cursor:pointer}.mpom details.om-dd\u003esummary::-webkit-details-marker{display:none}.mpom .om-dd-menu{position:absolute;left:0;top:calc(100% + 6px);min-width:100%;width:max-content;max-width:360px;background:#fff;border:1px solid #e3e5e8;border-radius:6px;box-shadow:0 8px 24px rgba(0,0,0,.14);z-index:30;padding:6px}.mpom .om-dd-menu a{display:flex;justify-content:space-between;align-items:center;gap:14px;padding:10px 12px;border-radius:4px;font-size:14px;font-weight:600;color:#2a2b2a!important;text-decoration:none!important}.mpom .om-dd-menu a:hover{background:#f5f6f8}.mpom .om-dd-menu small{font-weight:400;color:#5f6368;white-space:nowrap}\u003c\/style\u003e\u003cdiv class=\"mpom\"\u003e\n\u003cdiv class=\"om-head\"\u003e\n\u003cdiv\u003e\n\u003cspan class=\"om-tag\"\u003eINSTALLATION MANUAL\u003c\/span\u003e\u003cp class=\"om-lead\"\u003eSizes and the step-by-step fitting of the Wichard 7321 to 7324 anti-torque cable clamps round a thimble, with or without a vice, for furling sails.\u003c\/p\u003e\n\u003cdiv class=\"om-box\"\u003e\n\u003cdiv class=\"om-row\"\u003e\n\u003cspan\u003eDocument\u003c\/span\u003e\u003cb\u003eWichard Anti-Torque Cable Clamps Installation Guide\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-row\"\u003e\n\u003cspan\u003eFormat\u003c\/span\u003e\u003cb\u003ePDF · 2 pages · 1.0 MB\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-row\" style=\"border-bottom:0\"\u003e\n\u003cspan\u003eLanguage\u003c\/span\u003e\u003cb\u003eEnglish\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-acts\"\u003e\u003ca class=\"om-btn dl\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Wichard-Anti-Torque-Cable-Clamps-7321-7324-Installation-Guide.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003csvg viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2.4\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M12 4v11\"\u003e\u003c\/path\u003e\u003cpath d=\"m7 10 5 5 5-5\"\u003e\u003c\/path\u003e\u003cpath d=\"M5 20h14\"\u003e\u003c\/path\u003e\u003c\/svg\u003e Download PDF\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-toc\"\u003e\n\u003ca href=\"#om-specs\"\u003eSpecifications\u003c\/a\u003e\u003ca href=\"#om-install\"\u003eFitting\u003c\/a\u003e\u003ca href=\"#om-products\"\u003eProducts\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-img\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/files\/Wichard-Anti-Torque-Cable-Clamps-7321-7324-Installation-Guide-Cover.png\" alt=\"Wichard Anti-Torque Cable Clamps — Installation Guide\" loading=\"lazy\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-specs\"\u003e\n\u003ch2 class=\"om-h\"\u003eAnti-Torque Cable Clamps\u003c\/h2\u003e\n\u003cdiv class=\"om-tbl nw\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePart #\u003c\/th\u003e\n\u003cth\u003eØ cable\u003c\/th\u003e\n\u003cth\u003eA mm\u003c\/th\u003e\n\u003cth\u003eB mm\u003c\/th\u003e\n\u003cth\u003eL mm\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7321\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003ctd\u003e29\u003c\/td\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7322\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7323\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e62\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7324\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp class=\"om-note\"\u003eWARNING: non structural product, does not maintain the mast – only for furling sails.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGennaker or code 0: the clamps must be fitted with the Marlow Prodrive2 anti-torque cable.\u003c\/li\u003e\n\u003cli\u003eAsymmetric spinnaker: most anti-torque cables on the market can be fitted with the clamps.\u003c\/li\u003e\n\u003cli\u003eMaterial shown in the notice: clamp, 4 long screws, 10 short screws (14 short screws for 7324), two heat-shrink sleeves, plus grease.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"om-block\" id=\"om-install\"\u003e\n\u003ch2 class=\"om-h\"\u003eFitting the Clamp\u003c\/h2\u003e\n\u003ch3\u003eStep 1: Preparation\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eThread the two heat-shrink sleeves onto the anti-torque cable: the short one first, then the bigger one.\u003c\/li\u003e\n\u003cli\u003eRemove the 4 long screws from the clamp.\u003c\/li\u003e\n\u003cli\u003ePut the anti-torque cable around the thimble. Measure and mark the tail length: Ø9: 21-23cm, Ø11: 21-23cm, Ø13: 23-25cm, Ø15: 28-31 cm (these values may change according to the thimble).\u003c\/li\u003e\n\u003cli\u003ePlace the clamp between the 2 lines, approx. 10 mm max. from the thimble as shown in the notice.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eStep 2: Fitting without a vice\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eGrease the 4 long screws and fit them.\u003c\/li\u003e\n\u003cli\u003eTighten from the opposite side, progressively and crosswise, so the clamp closes evenly on both lines.\u003c\/li\u003e\n\u003cli\u003eComplete installation: replace the long screws with the greased short screws (10 short screws, 14 for 7324).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eStep 2bis: Installation with a vice\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003eClose the clamp in a vice between aluminium jaws, then fit the greased short screws (10, or 14 for 7324) and tighten from the opposite side.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eFinal tightening and finishing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTighten all screws to finish; the notice photos show the correct result with both lines fully seated.\u003c\/li\u003e\n\u003cli\u003eSlide the heat-shrink sleeve over the clamp area and shrink it with a heat gun.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp class=\"om-note\"\u003eNeed a part that isn't listed? \u003ca href=\"\/pages\/contact\"\u003eAsk us to source it\u003c\/a\u003e and quote the part number from the PDF.\u003c\/p\u003e\n\u003ch2 class=\"om-h\" id=\"om-products\"\u003eProducts in this Manual\u003c\/h2\u003e\n\u003c\/div\u003e","products":[],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0879\/4908\/2930\/collections\/Wichard-Anti-Torque-Cable-Clamps-7321-7324-Installation-Guide-Cover.png?v=1793136806","url":"https:\/\/www.mauripro.com\/collections\/owners-manuals-wichard-anti-torque-cable-clamps.oembed","provider":"MAURIPRO Sailing","version":"1.0","type":"link"}