Technical Data
Model code example DP1 P 3 12 D: series, gearbox (P = technopolymer, – = aluminium), power, voltage (V), D = drum / – = no drum.
DP1 P & DP2 P – 300 / 500 W
|
300W 12V |
500W 12V |
500W 24V |
HI SPEED 500W 12V |
HI SPEED 500W 24V |
| Maximum instantaneous pull |
370 kg (815.7 lb) |
660 kg (1455.0 lb) |
660 kg (1455.0 lb) |
600 kg (1322.8 lb) |
600 kg (1322.8 lb) |
| Maximum work load |
120 kg (264.5 lb) |
200 kg (440.9 lb) |
220 kg (485.0 lb) |
170 kg (374.8 lb) |
200 kg (440.9 lb) |
| Work load |
40 kg (88.2 lb) |
65 kg (143.3 lb) |
70 kg (154.3 lb) |
65 kg (143.3 lb) |
70 kg (154.3 lb) |
| Current at work load (DP1 / DP2) |
60 A / 65 A |
80 A |
40 A |
100 A |
50 A |
| Max recovery speed DP1 |
26.3 m/min (86.3 ft/min) |
25.2 m/min (83.0 ft/min) |
25.2 m/min (83.0 ft/min) |
39.0 m/min (128.0 ft/min) |
39.0 m/min (128.0 ft/min) |
| Max recovery speed DP2 |
29.2 m/min (95.8 ft/min) |
28.9 m/min (94.8 ft/min) |
28.2 m/min (92.5 ft/min) |
43.0 m/min (141.1 ft/min) |
42.5 m/min (139.4 ft/min) |
| Speed at work load DP1 |
22.5 m/min (73.8 ft/min) |
18.5 m/min (60.7 ft/min) |
19.3 m/min (63.3 ft/min) |
28.5 m/min (93.5 ft/min) |
28.0 m/min (91.8 ft/min) |
| Speed at work load DP2 |
24.4 m/min |
24.3 m/min |
24.1 m/min |
34.5 m/min |
35 m/min |
| Min. motor cable section |
16 mm² (AWG5) |
16 mm² (AWG5) |
10 mm² (AWG7) |
25 mm² (AWG3) |
10 mm² (AWG7) |
| Circuit breaker |
50 A |
60 A |
40 A |
80 A |
40 A |
Deck thickness: DP1 20 ÷ 30 mm (25/32" ÷ 1" 3/16); DP2 25 ÷ 50 mm (63/64" ÷ 1" 31/32). Weight without / with drum: DP1 8.3 / 9.3 Kg (18.3 / 20.5 lb); DP2 9.0 / 9.8 Kg (19.8 / 21.6 lb). HI SPEED only on request.
DP2 P 700 / 1000 W and DP3 P 700 / 1000 W
|
DP2 700W 12V |
DP2 700W 24V |
DP2 1000W 12V |
DP2 1000W 24V |
DP3 700W 12V |
DP3 700W 24V |
DP3 1000W 12V |
DP3 1000W 24V |
| Max instantaneous pull |
680 kg (1499 lb) |
680 kg (1499 lb) |
930 kg (2050 lb) |
930 kg (2050 lb) |
850 kg (1873.9 lb) |
850 kg (1873.9 lb) |
1000 kg (2204.6 lb) |
1000 kg (2204.6 lb) |
| Max work load |
300 kg (661 lb) |
320 kg (705 lb) |
420 kg (925 lb) |
480 kg (1058 lb) |
250 kg (551.1 lb) |
300 kg (661.4 lb) |
370 kg (815.7 lb) |
450 kg (992 lb) |
| Work load |
100 kg (220 lb) |
170 kg (235 lb) (as printed) |
140 kg (308 lb) |
160 kg (352 lb) |
80 kg (176.4 lb) |
100 kg (220.5 lb) |
120 kg (264.5 lb) |
150 kg (330.7 lb) |
| Current at work load |
95 A |
50 A |
130 A |
75 A |
90 A |
55 A |
140 A |
80 A |
| Max recovery speed |
22.6 m/min (74.15 ft/min) |
25.3 m/min (83.0 ft/min) |
31.2 m/min (102.4 ft/min) |
30.1 m/min (98.8 ft/min) |
27.4 m/min (89.9 ft/min) |
26.4 m/min (86.6 ft/min) |
39.6 m/min (129.9 ft/min) |
40.9 m/min (134.2 ft/min) |
| Speed at work load |
11.6 m/min (38 ft/min) |
14.4 m/min (47.2 ft/min) |
16.5 m/min (54 ft/min) |
19.1 m/min (62.6 ft/min) |
14.4 m/min (47.2 ft/min) |
14.8 m/min (48.5 ft/min) |
20.4 m/min (66.9 ft/min) |
21.4 m/min (70.2 ft/min) |
| Min. motor cable section |
25 mm² (AWG3) |
10 mm² (AWG7) |
35 mm² (AWG3) |
16 mm² (AWG7) |
25 mm² (AWG3) |
10 mm² (AWG7) |
35 mm² (AWG2) |
16 mm² (AWG5) |
| Circuit breaker |
50 A |
40 A |
80 A |
50 A |
50 A |
40 A |
80 A |
50 A |
| Weight without / with drum |
12.8 / 13.7 Kg |
12.8 / 13.7 Kg |
14.2 / 15.1 Kg |
14.2 / 15.1 Kg |
16.4 / 18.4 Kg |
16.4 / 18.4 Kg |
17.4 / 19.4 Kg |
17.4 / 19.4 Kg |
Deck thickness 25 ÷ 50 mm (63/64" ÷ 1" 31/32) for both. DP2 speeds measured with a 6 mm chain gypsy, DP3 with an 8 mm gypsy. AWG equivalents copied as printed.
DP3 1500 W
|
1500W 12V |
1500W 24V |
| Max instantaneous pull |
1100 Kg (2425.1 lb) |
1100 Kg (2425.1 lb) |
| Max work load |
470 kg (1036.2 lb) |
540 kg (1190.5 lb) |
| Work load |
160 Kg (352.7 lb) |
180 kg (396.8 lb) |
| Current at work load |
155 A |
85 A |
| Max recovery speed |
29.2 m/min (95.8 ft/min) |
29.7 m/min (97.4 ft/min) |
| Speed at work load |
16.3 (53.5 ft/min) |
19.0 (62.3 ft/min) |
| Min. motor cable section |
50 mm² (AWG0) |
25 mm² (AWG7) |
| Circuit breaker |
100 A |
50 A |
| Deck thickness |
30 ÷ 50 mm (1" 3/16" ÷ 1" 31/32) |
30 ÷ 50 mm |
| Weight without / with drum |
21.3 / 23.2 Kg (46 / 51 lb) |
21.3 / 23.2 Kg (46 / 51 lb) |
Current consumption after an initial period of use. Cable section is the minimum for a total cable length L < 20 m: size up for longer runs. Breaker: DC delayed-action thermal-magnetic or hydraulic-magnetic. Shafts and studs for thicker decks on request.
Spare Parts

DP1 (exploded drawing page 16)

DP2 (exploded drawing page 17)
| Code |
Description |
Parts (drawing ref.) |
|
| FVSSBDP20140A00 |
OSP GYPSY DP2 1/4" |
7 - 9 |
Ask us to source it → |
| FVSSBDP20516A00 |
OSP GYPSY DP2 5/16" |
7 - 9 |
Ask us to source it → |
| FVSSBDP20600A00 |
OSP GYPSY DP2 6MM |
7 - 9 |
Ask us to source it → |
| FVSSBDP20800A00 |
OSP GYPSY DP2 8MM |
7 - 9 |
Ask us to source it → |
| FVSSBDP2LC00A00 |
OSP WINDLASS BASE DP2 SERIES COMP |
from 23 to 41 |
Ask us to source it → |
| FVSSBDP2SC00A00 |
OSP WINDLASS BASE DP2 SERIES COMP |
from 23 to 41 |
Ask us to source it → |
| FVSSCPSCDP20A00 |
OSP CHAIN GUIDE COVER KIT DP2 |
23 |
Ask us to source it → |
| FVSSTDP2DL01A00 |
OSP TOP DP2 D L 1/4" |
3 - 4, from 6 to 15, 17 - 20, from 22 to 41 |
Ask us to source it → |
| FVSSTDP2DL05A00 |
OSP TOP DP2 D L 5/16" |
as above |
Ask us to source it → |
| FVSSTDP2DL06A00 |
OSP TOP DP2 D L 6MM |
as above |
Ask us to source it → |
| FVSSTDP2DL08A00 |
OSP TOP DP2 D L 8MM |
as above |
Ask us to source it → |
| FVSSTDP2DS01A00 |
OSP TOP DP2 D S 1/4" |
3 - 4, from 6 to 15 - 19, from 21 to 41 |
Ask us to source it → |
| FVSSTDP2DS05A00 |
OSP TOP DP2 D S 5/16" |
as above |
Ask us to source it → |
| FVSSTDP2DS06A00 |
OSP TOP DP2 D S 6MM |
as above |
Ask us to source it → |
| FVSSTDP2DS08A00 |
OSP TOP DP2 D S 8MM |
as above |
Ask us to source it → |
| FVSSTDP20L01A00 |
OSP TOP DP2 L 1/4" |
from 5 to 16 - 20, from 23 to 41 |
Ask us to source it → |
| FVSSTDP20L05A00 |
OSP TOP DP2 L 5/16" |
as above |
Ask us to source it → |
| FVSSTDP20L06A00 |
OSP TOP DP2 L 6MM |
as above |
Ask us to source it → |
| FVSSTDP20L08A00 |
OSP TOP DP2 L 8MM |
as above |
Ask us to source it → |
| FVSSTDP20S01A00 |
OSP TOP DP2 S 1/4" |
from 5 to 15 - 18 - 21, from 23 to 41 |
Ask us to source it → |
| FVSSTDP20S05A00 |
OSP TOP DP2 S 5/16" |
as above |
Ask us to source it → |
| FVSSTDP20S06A00 |
OSP TOP DP2 S 6MM |
as above |
Ask us to source it → |
| FVSSTDP20S08A00 |
OSP TOP DP2 S 8MM |
as above |
Ask us to source it → |
| FVSSADP2000LA00 |
OSP SHAFT KIT DP2 L |
11, from 13 to 16, 20 |
Ask us to source it → |
| FVSSADP2000SA00 |
OSP SHAFT KIT DP2 S |
11, from 13 to 15, 18 - 21 |
Ask us to source it → |
| FVSSADP200DLA00 |
OSP SHAFT KIT DP2 D L |
11, from 13 to 15, 17 - 20 - 22 |
Ask us to source it → |
| FVSSADP200DSA00 |
OSP SHAFT KIT DP2 D S |
11, from 13 to 15, 19 - 21 - 22 |
Ask us to source it → |
| FVSSCFASC000A00 |
OSP CLUTCH CONE KIT DP2 |
6 - 8 |
Ask us to source it → |
| FVSSCPBBASG0A00 |
OSP GYPSY COVER DP2 |
5 |
Ask us to source it → |
| FVSSMSE0800XA00 |
OSP WINDLASS DRUM DP2 |
4 |
Ask us to source it → |
| FVSSPSCDP200A00 |
OSP CHAIN PIPE KIT DP2 |
24 - 25 - 29 - 30 - 32 |
Ask us to source it → |
| FVSSGMSDCP05000 |
OSP DRUM BUSH DP2 |
3 |
Ask us to source it → |
| FVSSLVSDN000A00 |
OSP STRAIGHT WINDLASS LEVER |
2 |
Ask us to source it → |
| FVSSLVSP00R2A00 |
OSP CURVED WINDLASS LEVER R2 |
1 |
Ask us to source it → |

DP3 (exploded drawing page 18)

Motorgearboxes