INSTALLATION MANUALTechnical data, battery and fuse sizing, tunnel installation, electrical and V-CAN connection, protections, troubleshooting and service parts for the whole Vetus BOW PRO brushless proportional thruster range, BOWA0301 to BOWB420 (110 to 400 mm tunnels).
DocumentVetus BOW PRO Thrusters Installation & User Manual
FormatPDF · 58 pages · 15.9 MB
LanguageEnglish
This manual is split into 2 pages: Part 1 · Part 2 →
BOW PRO Technical Data
| Model |
Rated thrust |
Tunnel |
Supply |
Motor |
Current (In) |
Power |
Rating |
Weight |
| BOWA0301 |
30 kgf (66 lbf) |
110 mm |
12 V |
EC 8VAC-1.2kW |
174 A @ 12,0 V |
2,1 kW |
S2 - 10 min. |
24 kg (53 lbs) |
| BOWA0304 |
30 kgf (66 lbf) |
110 mm |
48 V |
EC 8VAC-1.2kW |
45 A @ 48,0 V |
2,1 kW |
S2 - 10 min. |
24 kg (53 lbs) |
| BOWA0361 |
36 kgf (79 lbf) |
125 mm |
12 V |
EC 8VAC-1.2kW |
240 A @ 12,0 V |
2,9 kW |
S2 - 10 min. |
26 kg (57 lbs) |
| BOWA0364 |
36 kgf (79 lbf) |
125 mm |
48 V |
EC 8VAC-1.2kW |
61 A @ 48 V |
2,9 kW |
S2 - 10 min. |
26 kg (57 lbs) |
| BOWA0421 |
42 kgf (93 lbf) |
125 mm |
12 V |
EC 8VAC-2.7kW |
218 A @ 12,0 V |
2,6 kW |
S2 - 10 min. |
26 kg (57 lbs) |
| BOWA0401 |
40 kgf (88 lbf) |
140 mm |
12 V |
EC 8VAC-2.7kW |
295 A @ 12,0 V |
3,5 kW |
S2 - 10 min. |
31 kg (68 lbs) |
| BOWA0571 |
57 kgf (126 lbf) |
150 mm |
12 V |
EC 8VAC-2.7kW |
295 A @ 12,0 V |
3,5 kW |
S2 - 10 min. |
31 kg (68 lbs) |
| BOWA0574 |
57 kgf (126 lbf) |
150 mm |
48 V |
EC 15VAC-3.1kW |
72 A @ 48 V |
4,0 kW |
S2 - 10 min. |
31 kg (68 lbs) |
| BOWB057 |
57 kgf (126 lbf) |
150 mm |
24 V |
EC 15VAC-3.1kW |
141 A @ 24,0 V |
4,0 kW |
S2 - 10 min. |
31 kg (68 lbs) |
| BOWA0651 |
65 kgf |
185 mm |
12 V |
EC 8VAC-2.7kW |
237 A @ 12,0 V |
2,9 kW |
S2 - 10 min. |
35 kg (77 lbs) |
| BOWA0761 |
76 kgf (168 lbf) |
185 mm |
12 V |
EC 8VAC-2.7kW |
322 A @ 12,0 V |
3,9 kW |
S2 - 5 min. |
35 kg (77 lbs) |
| BOWA0764 |
76 kgf (tech data: 900 N / 90 kgf, as printed) |
185 mm |
48 V |
EC 15VAC-3.1kW |
82 A @ 48,0 V |
3,9 kW |
S2 - 10 min. |
35 kg (77 lbs) |
| BOWB065 |
65 kgf (143 lbf) |
185 mm |
24 V |
EC 15VAC-3.1kW |
119 A @ 12,0 V (as printed) |
2,9 kW |
S2 - 10 min. |
35 kg (77 lbs) |
| BOWB076 |
76 kgf (168 lbf) |
185 mm |
24 V |
EC 15VAC-3.1kW |
166 A @ 24,0 V |
3,9 kW |
S2 - 10 min. |
35 kg (77 lbs) |
| BOWB090 |
90 kgf (198 lbf) |
185 mm |
24 V |
EC 15VAC-5.7kW |
192 A @ 24,0 V |
4,6 kW |
S2 - 10 min. |
35 kg (77 lbs) |
| BOWB110 |
110 kgf (tech data: 900 N / 90 kgf, as printed) |
185 mm |
24 V |
EC 15VAC-5.7kW |
288 A @ 24,0 V |
6,9 kW |
S2 - 10 min. |
35 kg (77 lbs) |
| BOWB130 |
130 kgf (286 lbf) |
185 mm |
24 V |
EC 15VAC-5.7kW |
300 A @ 24,0 V |
7,2 kW |
S2 - 10 min. |
35 kg (77 lbs) |
| BOWB150 |
150 kgf (330 lbf) |
250 mm |
24 V |
EC 15VAC-5.7kW |
242 A @ 24,0 V |
5,8 kW |
S2 - 6 min. |
42 kg (93 lbs) |
| BOWB180 |
180 kgf (396 lbf) |
250 mm |
48 V |
AC 29VAC-11kW |
238 A @ 44 V |
10,5 kW |
S2 - 10 min. |
44.5 kg (98 lbs) |
| BOWB210 |
210 kgf (463 lbf) |
250 mm |
48 V |
AC 29VAC-11kW |
275 A @ 44 V |
12,1 kW |
S2 - 10 min. |
44.5 kg (98 lbs) |
| BOWB285 |
285 kgf |
300 mm |
48 V |
AC 29VAC 18.4kW |
365A @48V |
17,5 kW |
S2 - 10 min. |
72 kg (159 lbs) |
| BOWB300 |
300 kgf |
300 mm |
48 V |
AC 29VAC 18.4kW |
378A @48V |
18,17 kW |
S2 - 10 min. |
72 kg (159 lbs) |
| BOWB320 |
320 kgf |
300 mm |
48 V |
AC 29VAC 18.4kW |
390A @48V |
18,7 kW |
S2 - 10 min. |
72 kg (159 lbs) |
| BOWB385 |
385 kgf |
400 mm |
48 V |
AC 29VAC 18.4kW |
480A @48V |
23 kW |
S2 - 6 min. |
120 kg (265 lbs) |
| BOWB420 |
420 kgf |
400 mm |
48 V |
AC 29VAC 18.4kW |
520A @ 48V |
24,9 kW |
S2 - 6 min. |
120 kg (265 lbs) |
All models: IP44, insulation class F, bevel gear with helical teeth in an oil bath (outboard gear oil SAE80W or EP 90), 6-blade asymmetrical polyacetal (Delrin) propeller (3 blades on BOWB385 and BOWB420), control circuit blade fuse ‘ATO’ 5 A. Rating S2 ‘t’ min. = activation time ‘t’ min. continuously or a max. of ‘t’ min. per hour at maximum power. Weights exclude the thrust tunnel.
- B (Boosted) models up to BOWB210 have an integrated battery charger: 12 V / 80 A (BOWB057–BOWB150) or 24 V / 80 A (BOWB180, BOWB210). BOWB285–BOWB420 (MCVB600 controller): current boosted charge 120A @ 24V (maximum).
- MCVB boosted charge function: the 48 Volt motor can be used in an existing 24 V on-board grid; the 24 Volt bank connected to the boosted charge connection charges the 48 Volt bank, no extra charger needed. As standard it is only suitable for lead acid batteries.
Battery Capacity and Fuses
| Model |
Battery capacity required |
Main fuse (slow blow) |
Thruster fuse (slow blow) |
| BOWA0301 |
1 x 90 Ah - 12 V |
250 A – ZE250 |
200 A – ZE200 |
| BOWA0304 |
4 x 60 Ah - 12 V |
100 A – ZE100 |
80 A – ZE80 |
| BOWA0361 |
1 x 170 Ah - 12 V |
355 A – ZE355 |
300 A – ZE300 |
| BOWA0364 |
4 x 60 Ah - 12 V |
125 A – ZE125 |
100 A – ZE100 |
| BOWA0421 |
1 x 145 Ah - 12 V |
355 A – ZE355 |
300 A – ZE300 |
| BOWA0401 |
1 x 145 Ah - 12 V |
355 A – ZE355 |
300 A – ZE300 |
| BOWA0571 |
1 x 185 Ah - 12 V |
355 A – ZE355 |
300 A – ZE300 |
| BOWA0574 |
4 x 60 Ah - 48 V (as printed) |
125 A – ZE125 |
100 A – ZE100 |
| BOWB057 |
2 x 90 Ah - 12 V |
250 A – ZE250 |
200 A – ZE200 |
| BOWA0651 |
1 x 170 Ah - 12 V |
300 A – ZE300 |
250 A – ZE250 |
| BOWA0761 |
1 x 200 Ah - 12 V |
355 A – ZE355 |
300 A – ZE300 |
| BOWA0764 |
4 x 60 Ah - 12 V |
125 A – ZE125 |
100 A – ZE100 |
| BOWB065 |
2 x 90 Ah - 12 V |
200 A – ZE200 |
160 A – ZE160 |
| BOWB076 |
2 x 90 Ah - 12 V |
250 A – ZE250 |
200 A – ZE200 |
| BOWB090 |
2 x 145 Ah - 12 V |
250 A – ZE250 |
200 A – ZE200 |
| BOWB110 |
2 x 170 Ah - 12 V |
355 A – ZE355 |
300 A – ZE300 |
| BOWB130 |
2 x 185 Ah - 12 V |
355 A – ZE355 |
300 A – ZE300 |
| BOWB150 |
2 x 170 Ah - 12 V |
355 A – ZE355 |
300 A – ZE300 |
| BOWB180 |
4 x 185 Ah - 12 V |
300 A – ZE300 |
250 A – ZE250 |
| BOWB210 |
4 x 185 Ah - 12 V |
300 A – ZE300 |
250 A – ZE250 |
| BOWB285 |
4 x 220 Ah - 12 V |
– |
425 A – ZE425 |
| BOWB300 |
4 x 220 Ah - 12 V |
– |
425 A – ZE425 |
| BOWB320 |
4 x 220 Ah - 12 V |
– |
425 A – ZE425 |
| BOWB385 |
4 x 220 Ah - 12 V |
– |
500 A – ZE500 |
| BOWB420 |
4 x 220 Ah - 12 V |
– |
500 A – ZE500 |
- Cable cross-section depends on the total length of plus and minus cable; each installation manual has the full table (from 25 mm2 up to 2 x 150 mm2). With a larger battery capacity the thruster performs even better.
- Main fuse in the positive cable before the main switch, as close to the battery as possible; main switch in the positive cable (BATSW250, or 2-pole BATSW250T). Fuse holder: ZEHC100.
- The thruster fuse sits on the controller in the connection unit and must always be present; replace only with the same rating.
- Give each thruster its own battery bank close to it. Use only sealed batteries (e.g. Vetus SMF or AGM) if they share the thruster compartment.
- Vetus maintenance-free batteries: 55 Ah, 70 Ah, 90 Ah, 108 Ah, 120 Ah, 143 Ah, 165 Ah, 200 Ah and 225 Ah.
- For battery cables > 70 mm2 (OD > 17 mm, 11/16") use the BOWHPCK high power connection set (M10 bolts).
Tunnel Position and Hull Connection
- Place the tunnel as far forward as possible. Distance A in the drawing at least 0.5 x D; tunnel length B between 2 x D and 4 x D.
- A stern thruster can be added; two thrusters in tandem suit large boats. Do not fit 2 thrusters in one tunnel: it does not double the thrust.
- Motor can be mounted in various positions; support it if horizontal or angled, keep it clear of the maximum bilge water level, and never let the tailpiece protrude from the tunnel end.
- Hull connection: abrupt is reasonable, rounded (R about 0.1 x D) is better, sloping sides C of 0.1 to 0.15 x D are best. A fairing of length L between 1 x D and 3 x D lowers drag.
- Grid bars only where strictly necessary: rectangular section, never round, perpendicular to the expected waveform, overlapping, no more than shown.
- No copper-based antifouling; keep the zinc anode. On steel or aluminium tunnels insulate bolts and shaft (e.g. nylon bushes) from the tunnel.
- GRP tunnel: roughen down to the glass fibre, laminate with isophtalic polyester resin, seal sawn ends with resin; treat the wet side with epoxy or 2-component polyurethane paint.
| Tunnel |
Steel O.D. / wall |
Composite (GRP) O.D. / wall |
Aluminium O.D. / wall |
| 110 mm |
121 mm / 4.5 mm |
121 mm / 5 mm |
120 mm / 4 mm |
| 125 mm |
133 mm / 4 mm |
136 mm / 5 mm |
135 mm / 5 mm |
| 140 mm |
152,4 mm / 4,5 mm |
152,4 mm / 5,3 mm |
152,4 mm / 5 mm |
| 150 mm |
159 mm / 4,5 mm |
161.6 mm / 5 mm |
160 mm / 5 mm |
| 185 mm |
193.7 mm / 5,6 mm |
194.1 mm / 5 mm |
196 mm / 5,5 mm |
| 250 mm |
267 mm / 7.1 mm |
265.6 mm / 6.2 mm |
264 mm / 7 mm |
| 300 mm |
318 mm / 7,5 mm |
323 mm / 9 mm |
320 mm / 10 mm |
| 400 mm |
420 mm / 10 mm |
420 mm / 10 mm |
420 mm / 10 mm |
Each installation manual includes a 1:1 drilling template for the intermediate flange holes: print at 100%, check the scale and centre the pattern exactly on the tunnel centreline.
Mechanical
- Tailpiece: shim plate in place, one packing between tailpiece and tunnel, sealant (polyurethane e.g. Sikaflex-292, or silicone) on both faces.
- Grease the intermediate flange hole and all bolt threads with outboard gear grease (Vetus Shipping Grease VSG).
- Propeller on a greased shaft; it must run at least 1.5 mm (1/16") clear of the tunnel wall all round.
- Slide the flexible coupling so the spindle end aligns with the flange underside, tighten the lock screw; grease the input shaft with Molykote G-n plus; mount the motor and check the propeller turns easily by hand.
- Check for leaks as soon as the boat is relaunched.
Electrical
- Feed the battery cables through the cover glands, fit terminals and connect to the motor controller; fit the supplied spacer on the negative terminal (not on external-connection models).
- Tightening torque in the motor controller: max. 10 Nm (7 ft-lbf); cable terminals 8 - 10 Nm (6 - 7 ft-lbf).
- Supplied configured as a bow thruster; set the switch inside the cover for a stern thruster.
- CAN bus supply always 12 Volt (≥10 V, ≤16 V), e.g. via the E-DRIVE MPE1KB key switch; max. 40 metres network; terminating resistor at both ends; supply preferably mid-system.
- All DC negatives to one central point; with a DC/DC converter for the CAN bus, input and output minus must be jumpered.
- Check all electrical connections after 14 days.
Built-in Protections
- APB (Active Power Balancing): thrust maintained as battery voltage drops; ACC (Automatic Current Control) limits power if current rises too high.
- AVC (Active Voltage Control): power reduced at 10,5 Volts on a 12 Volt system (21 V at 24 V); the thruster stops at about 10 volts (about 20 V for 24 V).
- ATB (Active Temperature Balancing): output reduced slightly after very long continuous use; ABC (Active Blockage Control): motor switches off on a sudden overload such as an object in the tunnel.
- On a fault the panel sounds didahdididah (. -.. -) once and its LED flashes red; when cleared it sounds didi (..). The motor indicator LEDs show over-temperature, over-current/short circuit, battery voltage, blocked motor, general error, CAN communication and power reduction.
- No carbon brushes, so maintenance is minimal; see the Maintenance and Warranty Book.
Troubleshooting
| Symptom |
Check |
| Motor does not run |
Battery main switch ON; battery voltage 10.5 - 14.4 V (12 V), 21.0 - 28.8 V (24 V), 42.0 - 57.6 V (48 V); control current fuse, CAN bus supply fuse and main fuses (POWER LED off in these cases); overload; propeller free to turn. |
| Motor turns slowly |
Motor or controller too hot (reduced power); weed or fishing line in the propeller. |
| Control panel fuse blown |
Short circuit in the operating circuit; check the wiring. |
| Motor runs, no thrust |
Propeller blades damaged; drive pin broken (replace it and check the hub). The BOWB150 has no drive pin. |
| Panel does not switch on |
Press on/off a second time within 6 seconds; the joystick must be centred when pressing on/off. |
| CAN bus |
Supply on and 12VDC; both terminating resistors in place (old supplies have one built in); connectors clicked home; correct cables; network ≤ 40 meters; each node powered (pin 1 = 12 VDC positive, pin 3 = neutral). |
| Installation |
Thruster supply voltage at the controller terminals; configured as bow or stern; cable sizes and routing (cables must not press on the circuit board); spacer on the negative lug; glands tight; white thermal sensor connector and the 5 A controller fuse in place. |
Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.