DIMENSION DRAWING

Ratios, loads, installation dimensions and cable sizing for the Andersen 46ST and 52ST Compact Motor™ Below Deck electric winches, 12VDC (2 speed manual, variable speed electric), from the manufacturer's data sheets.

DocumentAndersen Compact Motor™ Below Deck Electric Winch 46ST & 52ST Data Sheets
FormatPDF · 1 page · 0.3 MB
LanguageEnglish
Andersen Compact Motor™ Below Deck Electric Winch 46ST & 52ST — Data Sheets

Product Information

46ST Compact Motor™ BD 12V 52ST Compact Motor™ BD 12V
Product no. RA2046014100, RA2046004100 RA2052014100, RA2052004100
Power ratio 1st 15.7:1 · 2nd 47.1:1 1st 16.2:1 · 2nd 52.5:1
Gear ratio 1st 2.8:1 · 2nd 8.4:1 1st 3.2:1 · 2nd 10.5:1
Maximum working load 1000kg (2200lb) 1200kg (2650lb)
Maximum pulling load (electric) 825kg (1818lb) 1150kg (2535lb)

Physical Dimensions

46ST 52ST
Rope size 8-14mm (5/16 - 9/16") 8-16mm (5/16 - 5/8")
Drum Ø D 89mm (3 1/2") 100mm (3 15/16")
Base Ø B 181mm (7 1/8") 200mm (7 7/8")
Height H 208mm (8 3/16") 227mm (8 15/16")
Line entry L 90mm (3 9/16") 106mm (4 3/16")
Max deck K 57mm (2 1/4") 56mm (2 3/16")
Motor Ø S 195mm (7 11/16") 250mm (9 7/8")
Motor height J 182mm (7 3/16") 179mm (7 1/16")
Motor offset Ox 32mm (1 1/4") 45mm (1 3/4")
Weight 21kg (46.3lb) 30kg (66.0lb)

Extensions are available to suit thicker decks. Full installation dimensions are in the product manuals.

Electrical Installation

Wire length Wire size Additional battery capacity per winch Minimum battery bank
0-10m (10-33ft) 25mm2 46ST: 64Ah · 52ST: 61Ah 150Ah
10-15m (33-49ft) 35mm2
15-20m (49-65ft) 50mm2

Wire length = battery to motor and back to battery. Additional capacity assumes one winch used 15 minutes (0.25hr) a day at 1/2 MWL, then 3 x the total Ah of all equipment as a rule of thumb; ask a qualified marine electrician. Minimum bank keeps 10.5V in 12V systems (21V in 24V systems) at start-up, based on battery CCA at -18C with fully charged batteries. The motor cuts out at pre-determined current and temperature limits; performance curves are in the data sheets.

  • Supplied with installation manual, push button, 1000mm (39") push button control cable and circuit breaker/controller.
  • A secondary push button RA866000, RA866010 or RA866020 can be added only if specified with the original order – it cannot be retrofitted.
  • Wiring: push button → control cable → motor; motor power via the circuit breaker/controller to the battery; thermal sensor wires from motor to the breaker/controller.

Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.