INSTALLATION MANUAL
Ratings, socket cut-outs, plug wiring and use of the Lofrans Galaxy 102 wired hand-held windlass remote.
DocumentLofrans Galaxy 102 Remote Control Installation & User's Manual
FormatPDF · 20 pages · 0.9 MB
LanguageEnglish

Technical Data
- DC only; must be used with contactors or a control box.
- Feeding tension 30 VCC max; normally open contacts.
- Do not use with a load more than 2 Amps (the Italian, French, German and Spanish sections print 3 A).
- Cable can be extended up to 4 mt.
- Case moulded in self-extinguishing polyester resin; IP 66 remote control, IP 67 plug and socket.
- Remote control dimensions 155x65x45 mm.
Socket Installation & Wiring
| Socket | Panel cut-out | Wiring |
|---|---|---|
| Bulgin connector | Ø20.5 hole, 4 × Ø2.2 screw holes on 33.3 × 33.3 | Up (red), Down (blue), Common (yellow) to the L, E, N terminals as drawn in the manual |
| KEFA connector (blue cover) | Ø21 hole, one Ø2.2 screw hole at 31 | 1 = Up (red), 2 = Down (blue), 3 = Common (yellow) |
- Always disconnect the battery during installation.
- Mount the socket in a dry place if possible.
- Connect per the wiring diagram of the windlass control box.
Using the Remote
- Push the plug into the socket and turn its locking ring clockwise until it stops.
- Switch on the power and check the buttons drive the windlass the right way; if not, swap the Up and Down wires at the socket.
- Press UP or DOWN to run the windlass; release to stop.
Never press both buttons together, and do not open the remote or the plug: that breaks the watertight seal and the warranty (2 years).
Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.