Technical Data

  • DC only; must be used with contactors or a control box.
  • Feeding tension 30 VCC max; normally open contacts.
  • Do not use with a load more than 2 Amps (the Italian, French, German and Spanish sections print 3 A).
  • Cable can be extended up to 4 mt.
  • Case moulded in self-extinguishing polyester resin; IP 66 remote control, IP 67 plug and socket.
  • Remote control dimensions 155x65x45 mm.

Socket Installation & Wiring

Socket Panel cut-out Wiring
Bulgin connector Ø20.5 hole, 4 × Ø2.2 screw holes on 33.3 × 33.3 Up (red), Down (blue), Common (yellow) to the L, E, N terminals as drawn in the manual
KEFA connector (blue cover) Ø21 hole, one Ø2.2 screw hole at 31 1 = Up (red), 2 = Down (blue), 3 = Common (yellow)
  • Always disconnect the battery during installation.
  • Mount the socket in a dry place if possible.
  • Connect per the wiring diagram of the windlass control box.

Using the Remote

  1. Push the plug into the socket and turn its locking ring clockwise until it stops.
  2. Switch on the power and check the buttons drive the windlass the right way; if not, swap the Up and Down wires at the socket.
  3. Press UP or DOWN to run the windlass; release to stop.

Never press both buttons together, and do not open the remote or the plug: that breaks the watertight seal and the warranty (2 years).