INSTALLATION MANUAL

Specifications, panel cut-out, wiring and operation of the Lofrans Touch Panel UP/DOWN, the two-button IP67 windlass control with three-minute auto shut-off.

DocumentLofrans Touch Panel UP/DOWN Installation & User's Manual
FormatPDF · 40 pages · 1.8 MB
LanguageEnglish
Lofrans Touch Panel UP/DOWN — Installation & User's Manual

Technical Data

Touch Panel UP/DOWN
Power supply Up to 30 V DC
Power consumption in standby 0 mA
No-load current intake 45 mA @ 12 V DC
Operating temperature −10 to +60 °C
Protection rating IP67 (front panel, water/dust)
Dimensions 65.5 × 65.5 × 50 mm
Weight 68 g
Standards EN 55032: 2015; EN 55035: 2017 (EN 61000-4-2:2009)
  • Two-button activation, so the windlass cannot be started by an accidental touch.
  • Smart high-side power switch with a wide operating voltage range.
  • Switches itself off after 3 minutes, with a buzzer notification.
  • Round back flange for a simple install.

In the Box

  • Touch Panel UP/DOWN
  • Sticker drilling template
  • Round back flange / rubber seal
  • 4 fixing screws
  • Installation and user's manual

Mounting

  • Stick the drilling template where you want the panel.
  • Cut a 52 mm hole with a hole saw.
  • Offer the panel into the hole, mark the 4 fixing holes, remove it and drill the 4 fixing holes (1 mm diameter, as printed).
  • Check the rubber seal sits on the base column.
  • Wire the unit per the wiring diagram, with the terminal block connector on the lower side behind the panel.
  • Fasten the base with the 4 screws supplied.
  • Only when wiring and position are final, clip on the face cover with the Lofrans logo on the left, and check the clear waterproof button covers are seated.
  • To remove the cover: push a flat screwdriver (6–7 mm tip) at least 3 to 4 mm between cover and dashboard, first at one side then the other, and twist slightly.

Wiring

Pin Signal
1 − battery
2 + battery
3 DOWN command
4 UP command
  • Always disconnect the battery before installation.
  • Wire cross section: 1.5 mm².
  • Fit a 5 A fast fuse on the positive (+) battery wire. Do not power the panel from the engine battery set.
  • The panel drives the windlass control box; the wiring diagram in the PDF also shows optional external remote switches.
  • Keep the back of the unit in a dry place if possible.
  • Wires go into a push-in connector with finger-operated release; no tools needed.

Operation

  • Switch on the power and check the windlass turns the right way. If not, swap the UP and DOWN wires at the connector.
  • Press both buttons together to turn the panel ON.
  • Press UP or DOWN to run the windlass; release to stop.
  • After 3 minutes the panel switches OFF by itself with a double beep.

Warranty

  • 2 years from the date of purchase by the original purchaser, in normal use and with the maintenance schedule followed.
  • 1 year for electrical boards, gaskets and seals, and all products used on charter boats.
  • Not covered: wrong product choice, use outside the design application or specification, corrosion, UV degradation and wear, skipped maintenance, incorrect installation, modifications, removal/transport/installation costs, maintenance by people not authorised by Lofrans.
  • Lofrans may refuse the warranty if the equipment is run with unsuited electrical accessories or without a suitable overload cut-out on the power line.
  • Claims are registered on the Lofrans website with the serial number of the control.

Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.