INSTALLATION MANUALInstall, plumb, wire and maintain the Max Power CT125 HYD hydraulic tunnel thruster (Ø185 tunnel): positioning and tunnel lamination, drive leg and motor torques, hydraulic specification, control connections and the spare parts list.
DocumentMax Power CT125 HYD Hydraulic Tunnel Thruster Installation Manual
FormatPDF · 18 pages · 2.3 MB
LanguageEnglish
Specifications
| Code |
Max thrust (kgf/lbs) |
Hydraulic power (kW) |
Propellers |
Weight (kg) |
| 317588 |
140 / 308 |
13,5 |
Duo |
12 |
| 317590 |
120 / 264 |
11 |
Duo |
12 |
| 317589 |
90 / 198 |
7,5 |
Duo |
12 |
- Hydraulic specification: flow 30/35 litres/min, pressure 130 / 140 bar.
- Data sheet dimensions: A 210, B 210, C 215, D 185 mm, E 6 to 7 mm. Composite construction, twin propellers, Ø185 mm tunnel.
- Delivered with: hydraulic motor & coupling, motor support, HYD controller, drive leg with propeller pins & coupling, 2 propellers, 2 safety stickers, manual.
Positioning & measurements (manual)
| Dim (mm) |
125 |
225 |
325 |
| A |
185 |
250 |
315 |
| B |
197 |
264 |
333 |
| C |
210 |
210 |
220 |
| D |
190 |
220 |
280 |
| T (tunnel thickness) |
6 |
7 |
9 |
| E ideal |
185 |
250 |
315 |
| E mini |
110 |
140 |
160 |
| Weight |
9 kg |
12 kg |
20 kg |
The manual table gives 9 kg for the 125; the data sheet gives 12 kg (as printed).
Boat sizing
| Boat type |
Boat length |
| Heavy displacement, high windage & cruising |
35' – 46' / 10,6 – 14 m |
| Medium displacement, medium windage & fast cruising |
42' – 55,5' / 12,8 – 17 m |
| Light displacement, light windage & super fast cruising |
46' – 60' / 14 – 18 m |
Control system safety features: Childproof activation; automatic shutdown after 30 minutes of inactivity; visible and audible overheat warning; time delay switch between port and starboard thrust; software protection against short circuits.
Tunnel
- Tunnel as low and as far forward as possible; propellers must not protrude beyond the hull line.
- Ideally at least one tunnel diameter of depth from the waterline to the top of the tunnel; poor immersion can be compensated by moving the tunnel further forward.
- Hydraulic units can be fitted vertically, horizontally or tilted.
- With tunnels of a different wall thickness (e.g. metallic), the zone between drive leg/gasket and motor support must match the thickness in the Positioning & Measurements table, with a stable motor support. Under 6 mm thickness, fit an extra hard rubber gasket between motor support and tunnel.
- Mark the tunnel centre, drill Ø 10 mm and trace the elliptical cut-out with a compass made from 8 mm rod. Disc the inside of the hull 10 to 15 cm around the holes.
- Laminate with at least 8 coats of mat and roving with isophthalic resin, filling the hull/tunnel gap with reinforced filler. No fibreglass on the motor support area; lightly sand it.
- Fair the tunnel ends with reinforced filler for clean water flow, then seal the whole area with epoxy or gel-coat.
Drive Leg, Motor & Propellers
Drive leg & motor support
- The leg gasket and the motor support can be used to mark up the drilling position; in some cases it is easier to mark out and drill before the tunnel is stratified.
- Fit the leg with its gasket in the tunnel and check the propeller tip clearance all round (folded cardboard works); slight adjustment to align the leg may be needed.
- Remount the assembly with the gasket coated in an oil- and salt-water-resistant jointing compound; remove all excess. The gasket goes between leg and tunnel, not between motor support and tunnel.
- Mating faces of leg and motor support must be dirt free with a light film of grease. Graphite grease must not be used.
- Torque: screw Ø 8 mm = 30 Nm; tighten the two fixing screws alternately. Once tightened, the propellers must turn freely without touching the tunnel.
- Composite drive leg: installed like the bronze leg, but it is lubricated for life, needs no anode and must not be dismantled, even partially.
- Use only the original leg screws (part 14) delivered with the drive leg: longer screws risk damaging the leg and letting water in.
Hydraulic motor
- Do not separate the motor from its adapter.
- Fit the lower metal coupling on the greased leg shaft, then the flexible coupling, then the motor with its adapter; tighten the screws (10mm) to 40 Nm.
- With a screwdriver push the lower coupling up towards the motor: there must be no slack or play between the parts.
- Tighten the drive key locking screw (3 mm Allen key with white mark).
Propellers
- Check the oil drain screw (8 mm Allen key) and the anode (10 mm key) are tight.
- Apply silicone grease to the shaft and seals before fitting the propellers, to prevent limestone deposits.
- Fit pins and propellers with the blades opposed, not in line. Tighten the screws (3 mm Allen key): only 2 mm should show above the hub; more means the screws are not in the shaft groove.
- In a shallow tunnel, horizontal protection grills are recommended; they do modify thruster performance.
Hydraulic System
- A typical installation: oil reservoir, hydraulic pump, directional control valve (DCV), hydraulic motor, piping and, depending on the installation, an oil cooler.
- Reservoir (with return filter and suction strainer) as close to the pump as possible and on charge: oil level above the pump. Keep the return filter accessible; an isolation valve can be fitted on the suction.
- The pump can be driven by the engine (crankshaft pulley or gearbox PTO) or an electric motor, and must match the rated pressure/flow of the thruster.
- DCV with pressure gauge and pressure relief valve, as close as possible to the thruster.
- Flexible or rigid/flexible piping with crimped fittings, matching interior diameters and service pressure; runs as direct as possible, kept clean and closed until connection. Hoses arriving at the thruster must be thermo-plastic non-conductive.
- Motor drain line and DCV return T-line each go separately and directly into the top of the oil tank.
- Oil: synthetic, mineral or vegetable hydraulic oil, ISO 32 to 48.
- Series 125 HYD: flow 30/35 litres/min, pressure 130 / 140 bar.
| Drive |
Pump types |
| Engine, direct PTO |
Fixed flow pump (always requires oil cooler); variable displacement pump, depending on the model, or fixed flow pump with bypass (oil cooler when operation exceeds 15 minutes, or not necessary) |
| Engine, PTO with clutch |
Fixed flow pump, variable displacement pump (depending on model) or fixed flow pump with bypass (oil cooler when operation exceeds 15 minutes, or not necessary) |
| DC electric motor |
Fixed flow pump (oil cooler not necessary) |
| AC electric motor |
Fixed flow pump or other (oil cooler when operation exceeds 15 minutes, or not necessary) |
Choices also depend on the capacity of the oil tank. Detailed instructions and diagrams come with each pack, specific to the installation chosen.
Hydraulic custom pack (tailor made)
- Electro pump pack: 1 × electro pump 24 Volt 8 kW, 1 power relay, 1 fuse holder, 1 power fuse.
- Hydraulic control pack (12 V / 24 V): 1 directional control valve (with pressure gauge and pressure relief valve) and 1 control panel.
- Reservoir pack: oil reservoir 8 / 12 / 18 / 40 litres with return filter, suction strainer, oil level sight gauge/thermometer, filler cap and motor drain connection.
| Pipe module |
M4 |
M5 |
M6 |
M8 |
M10 |
M12 |
M16 |
| Interior diameter |
1/4" |
5/16" |
3/8" |
1/2" |
5/8" |
3/4" |
1" |
| Max Power element ports (hydraulic diagram numbers) |
Intake |
| 1 / 2 / 11 |
Female BSP 3/4" |
| 3 / 6 / 7 / 8 / 9 |
Female BSP 1/2" |
| 4 / 5 |
Female BSP 3/8" |
| 10 / 12 |
Female BSP 1/4" |
Line runs over 1.5m: increase the size (as shown on the hydraulic diagram in the manual).
Control System Connections
Using an Electro-Hydraulic Pump
- Thruster battery bank (high CCA, starting type), power circuit fuse, electric battery isolator (optional with electro-hydraulic pump) and power relay.
- Electro-hydraulic pump with N/O heat sensor; hydraulic oil reservoir with N/O alarm sensor; service valve (DCV).
- Independent battery bank for the control circuit supply, through the yacht's main DC breaker board with an 8 A fuse.
- Electronic thruster controller (control box 315311) linked to the control panel by the 6-wire control cable and cable connectors A, B and C.
Using a Motor with Clutched PTO
- Clutch or bypass driven through a bi-polar clutch relay.
- Hydraulic oil reservoir with N/O alarm sensor and service valve (DCV).
- Independent battery bank for the control circuit, 8 A fuse on the main DC breaker board.
- Electronic thruster controller and control panel, same cable connectors A, B and C.
Full colour-coded wiring and the hydraulic diagram are in the manual PDF.
Maintenance
- Keep tunnel, leg and propellers clean.
- Before fitting the propellers, clean the shaft and oil seals and apply a layer of silicone oil to prevent chalky deposits.
-
Annually: change the anode if necessary; change the drive leg oil on a classic (bronze) leg; check the oil and the hydraulic filtration circuit (only if necessary).
-
Every 5 years: drain the hydraulic oil, change the filter and refill.
- Keep this manual on board.
Warranty
- Two years from purchase by the end user, transferable; it starts 6 months after the boat is delivered to the dealer.
- Register within 3 months of purchase for one extra year (3 years in total), with proof of purchase.
- Non-pleasure use: limited to six months.
- Excluded among others: installation contrary to published specifications, lack of normal maintenance, unauthorised repairs, normal wear and tear, cost of hauling the boat.
Spare Parts – MP 125 HYD