OWNER'S MANUAL

Installation, wiring, switch-on sequence, buzzer signals and dimensions of the Maxwell P102983 push-button anchor windlass control panel.

DocumentMaxwell Anchor Windlass Control Panel P102983 Installation & User Manual
FormatPDF · 2 pages · 0.4 MB
LanguageEnglish
Maxwell Anchor Windlass Control Panel P102983 — Installation & User Manual

Technical Data & Dimensions

Item Value
Part number P102983
Voltage 8 – 32 Volt
Max. current 3 A
Panel face 85 × 85 mm (3 3/8" × 3 3/8")
Body diameter ø75 mm (2 15/16")
Depth behind the mounting surface 78 mm (3 1/16"); face stands 7 mm (1/4") proud
Mounting panel thickness Min 3 mm (1/8") – max 25 mm (1")
Free space behind the panel Minimum 50 mm (2")

Connection Diagram

No. Component
1 Fuse (5 A)
2 Plug
3 Socket
4 Solenoid switch ‘Hauling in’
5 Solenoid switch ‘Letting go’
Wire Colour
A White
B Black (−)
C Red (+)
D Blue

Fit the panel in the wheelhouse. The full connection diagram is in the PDF download.

Using the Panel

  1. Switch on the main switch.
  2. Press the on/off switch twice: after the first press the LED flashes green and the buzzer sounds continuously; press again within 6 seconds. The LED stays green and the buzzer confirms the panel is ready.
  3. Operate the windlass motor with the direction switch.
  4. After use press the on/off switch once; the panel sounds a signal. It also switches off automatically 30 minutes after the last use of a direction switch.
  5. Switch off the main switch when leaving the ship.

If two control panels are installed, never operate the windlass from both panels at the same time.

Protection

  • Thermal protection of the control current: on overload the panel sounds a warning once and the LED lights red and green alternately for about 7 seconds.
  • Once the overload is solved the system works normally again.

Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.