INSTRUCTIONS

Technical data, photometrics, wiring and fitting for the Quick Action 5W and 10W LED utility (engine room) lights.

DocumentQuick Action LED Engine Room Lights Technical Sheets
FormatPDF · 4 pages · 0.3 MB
LanguageEnglish
Quick Action LED Engine Room Lights — Technical Sheets

Technical Data

Action 5W Action 10W
Light source 63 high luminosity LED 126 high luminosity LED
Light type One colour Bicolor (secondary light 0,3W)
Power supply (constant voltage) 9-16 VDC 10-30 Vdc
Power / absorption 5W; 0,32A @ 16V 10W; 0,83A@12V / 0,42A@24V
Luminous flux / efficacy (daylight) 314 lm; 63 lm/W 630 lm; 63 lm/W
Beam angle 90° 100°
Illuminance at 1 / 2 / 3 m 132,4 / 33,1 / 14,7 lux 266,1 / 66,5 / 29,6 lux
Beam Ø at 1 / 2 / 3 m 2,08 / 4,16 / 6,25 m 2,26 / 4,51 / 6,77 m
Size / weight 140 x 116 mm; 150 gr 140 x 116 mm; 170 gr
Mounting hole Ø 5 mm (sheet) Ø 8 mm
Colours White DL (code FAMP3112A11AA00) DL, white-blue, white-red; CRI 80
Recommended dimmer (PWM) FASP094CA2A3A00 HDIM300 FASP094CA2A3D00 HDIM300 D00
  • IP66; ceiling or wall, surface mounted (0 mm recess), fixed with screws; not orientable, no switch. Plastic body, polycarbonate diffuser.
  • Daylight colour temperature 3800-4100 °K (sheet bands: warm 2900-3100, daylight 3800-4100, cool 5500-6000 / 5500-6500 °K).

Fitting

  1. Drill a ø8mm hole in the panel for the power wires, in line with the hole in the light base.
  2. Connect the wires: positive to red, negative to black, and test.
  3. Set the light on the surface over the wire hole.
  4. Fix the base with self-tapping screws.

Wiring

  • Extra-low voltage (SELV) only, from a constant-voltage LED supply; never connect to AC mains.
  • Action 5W: units can be connected in parallel.
  • Action 10W (4 wires): for 24V join the inner black and red and use the outer red (+) and black (–); for 12V join both reds to + and both blacks to –, as drawn on the back of the light.

Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.