Technical Data

AISI 316 stainless tank, polyurethane foam insulation, AISI 304 stainless cladding, heat exchanger for the engine cooling circuit, electric element with adjustable and safety thermostat, relief/non-return valve that protects against overpressure and drains the heater.

Reading the Model Code

Part Meaning
BX Boiler Inox
15 – 100 Tank capacity in litres
Element power 00 = not installed, 05 = 500 W, 06 = 600 W (110 Vac only), 12 = 1200 W
S Heat exchanger present
Voltage - = 220 Vac, L = 110 Vac

Examples: BX2005S = 20 litres, 500 W, heat exchanger, 220 Vac. BX8012SL = 80 litres, 1200 W, heat exchanger, 110 Vac.

Model BX 15 BX 20 BX 25 BX 30 BX 40 BX 50 BX 60 BX 80 BX 100
Litres 15 20 25 30 40 50 60 80 100
US gallon 3.96 5.28 6.6 7.92 10.56 13.2 15.85 21.13 26.4
Weight empty (kg) 7,6 8,3 9,4 10,0 11,1 15,2 16,8 19,9 23,5
Weight empty (lb) 16.7 18.3 20.7 22.0 24.5 33.5 37.0 43.9 51.8
Item Value
Test pressure 800 kPa (1 Bar = 100 kPa)
Maximum working pressure 600 kPa
Element voltage 220 Vac ± 10% (110 Vac ± 10%)
Element power 500 W (model 05), 600 W (model 06, 110 Vac only), 1200 W (model 12)
Outputs 1/2"

Electric element voltage and power: some versions available on request.

In the Box

  • Water heater, mounting, bolts, nuts and screws, user's manual, conditions of warranty.

Installation and First Use

  • Dry, well-ventilated location: without ventilation condensation forms and can be mistaken for a leak. Never in closed or poorly ventilated rooms, or where gas or flammable material is present.
  • The listed weights are empty: add about 1 kg (2,2 lb) per litre of water when sizing the mounting.
  1. Fit the mounting (17) to the tank (1) with the studs and nuts supplied (18, 19, 20).
  2. Fix the heater on a flat surface, an inclined plane or a wall, with mountings suited to its weight and the site.
  3. Connect tap water in and out, and the engine cooling circuit to the heat exchanger, keeping that run as short as possible; follow the engine manufacturer's instructions for the coolant connection.
  4. Use Loctite 243, 577 or Teflon on the fittings and check for leaks.
  5. Fit the discharge pipe (7) to the relief valve (5) with the hose clamp (6), sloping evenly downwards, protected from ice and open to the atmosphere: it may drip.
  6. Open the hot taps and start the water pump to push the air out; close the taps when air-free water flows. Check all joints.

Power Supply and Thermostat

  • AC power cable supplied (brown live, blue neutral, yellow/green earth). Fit a double pole switch and a suitably rated fuse; at least 3 mm insulation between contacts; follow national wiring standards. Check the supply voltage matches the element.
  • Never switch on the element unless the heater is completely full of water: the element is destroyed and the double thermostat protection fails.
  • Thermostat: standard setting 60°C. Power off, remove the protection cover (12), turn the knob with a screwdriver, refit the cover and power on. It regulates the water temperature only when heating electrically.
  • Over-temperature: the double thermostat with manual reset cuts the power. Power off, remove the cover (12), press the reset button on the double thermostat, refit the cover and power on. If it trips repeatedly, call a Quick service centre.
  • A damaged power cable must be replaced by a Quick service centre; opening the unit without authorisation voids the warranty.

Maintenance

  • Check the magnesium anode (A) every 12 months; replace it if significantly reduced.
  • In winter, if the heater is not used, drain it with the lever of the valve (5) to avoid freezing damage.
  • Operate the overpressure release device regularly to clear calcium deposits and make sure it is not blocked.
  • Periodically check the water joints, the tightness of the securing screws (replace if worn or corroded) and the electrical system.

Spare Parts

Quick BX 15-100 water heater exploded view with position numbers

Code Pos. Description
MLB15260S000 1A Tank 15L with heat exchanger Ask us to source it →
MLB20260S000 1B Tank 20L with heat exchanger Ask us to source it →
MLB25260S000 1C Tank 25L with heat exchanger Ask us to source it →
MLB30320S000 1D Tank 30L with heat exchanger Ask us to source it →
MLB40320S000 1E Tank 40L with heat exchanger Ask us to source it →
MLB50360S000 1F Tank 50L with heat exchanger Ask us to source it →
MLB60360S000 1G Tank 60L with heat exchanger Ask us to source it →
MLB80360S000 1H Tank 80L with heat exchanger Ask us to source it →
MLB100360S00 1I Tank 100L with heat exchanger Ask us to source it →
PECRBLRS0000 2 Red plastic washer Ask us to source it →
PECRBLBNC000 3 White plastic washer Ask us to source it →
PECRBLBL0000 4 Blue plastic washer Ask us to source it →
MNVALS12S68P 5 Relief/non return valve Ask us to source it →
PBF25100W000 6 Hose clamp Ask us to source it →
PVTBGM10NT00 7 Discharge pipe Ask us to source it →
PGGRES000000 8A Element gasket from S/N 100.000 Ask us to source it →
PGRM43500000 8B Element gasket from S/N 200.000 Ask us to source it →
EVR12220N000 9A Electric element 1200W 220V Ask us to source it →
EVR05220N000 9B Electric element 500W 220V Ask us to source it →
EVR12110N000 9C Electric element 1200W 110V Ask us to source it →
EVR06110N000 9D Electric element 600W 110V Ask us to source it →
EVT15S000000 10 Bi-thermostat Ask us to source it →
ECC30150G000 11 Power supply cable Ask us to source it →
PECRB2200000 12A Boiler resistor cover 220V Ask us to source it →
PECRB1100000 12B Boiler resistor cover 110V Ask us to source it →
MBD04MXEN000 13 Nut Ask us to source it →
EJCY04000000 14 Ground cable terminal Ask us to source it →
MBR04X000000 15 Washer Ask us to source it →
MBV02919AXCC 16 Screw 2,9 X 19 Ask us to source it →
MMSTBL300DR1 17A Tank mounting BX15-BX20-BX25 Ask us to source it →
MMSTBL400DR1 17B / 17C Tank mounting BX26-BX30-BX40 / BX41-BX50-BX60-BX80 (same code printed) Ask us to source it →
MBV0830MXE00 18 Bolt Ask us to source it →
MBR08X000000 19 Washer Ask us to source it →
MBD08MXEN000 20 Nut Ask us to source it →
PPBLBX000000 21 Cable clamp Ask us to source it →
MBV02916AXCC 22 Screw 2,9 X 16 Ask us to source it →

Dimensions

mm (inch). A = overall length, H = tank diameter; the other letters refer to the drawing in the PDF.

Model A B C D E F G H I L M
BX 15 / 20 / 25 405 / 500 / 605 316 133 68 278 62 64 Ø 300 323 96 268
BX 30 / 40 495 / 620 384 153 70 318 84,5 84,5 Ø 360 363 74 320
BX 50 / 60 / 80 / 100 610 / 715 / 905 / 1105 422 157 70 357 99 115 Ø 400 403 61 355