INSTALLATION MANUAL

Model code, technical data, installation, power supply, thermostat setting and reset, maintenance, spare part codes and dimensions for the Quick BXS square stainless steel water heaters, 25 and 40 litres.

DocumentQuick BXS 25–40 L Water Heaters Installation & User's Manual
FormatPDF · 56 pages · 1.5 MB
LanguageEnglish
Quick BXS 25–40 L Water Heaters — Installation & User's Manual

Technical Data

Square (S line) water heater: AISI 316 stainless tank, polyurethane foam insulation, AISI 304 stainless cladding, heat exchanger, electric element with adjustable and safety thermostat, relief/non-return valve.

Reading the Model Code

Part Meaning
BX Boiler Inox
S Square line
25 / 40 Tank capacity in litres
Element power 05 = 500 W, 06 = 600 W (110 Vac only), 12 = 1200 W
S Heat exchanger present
Voltage - = 220 Vac, L = 110 Vac

Examples: BXS2505S = 25 litres, 500 W, heat exchanger, 220 Vac. BXS4012SL = 40 litres, 1200 W, heat exchanger, 110 Vac.

Item BXS 25 BXS 40
Capacity 25 l (6.6 US gal) 40 l (10.56 US gal)
Weight (empty) 10,5 kg (24.1 lb) 13,9 kg (30.6 lb)
Item Value
Test pressure 800 kPa (1 Bar = 100 kPa)
Maximum working pressure 600 kPa
Element voltage 220 Vac ± 10% (110 Vac ± 10%)
Element power 500 W (model 05), 600 W (model 06, 110 Vac only), 1200 W (model 12)
Outputs 1/2"

Electric element voltage and power: some versions available on request.

In the Box

  • Water heater, bolts, nuts and screws, user's manual, conditions of warranty.

Installation and First Use

  • Dry, well-ventilated location: without ventilation condensation forms and can be mistaken for a leak.
  • The listed weights are empty: add about 1 kg (2,2 lb) per litre of water when sizing the mounting.
  1. Fix the heater on a flat surface with mountings suited to its weight and the site.
  2. Connect tap water in and out, and the engine cooling liquid in and out of the heat exchanger, keeping that run as short as possible; follow the engine manufacturer's instructions for the coolant connection.
  3. Use Loctite 243, 577 or Teflon on the fittings and check for leaks.
  4. Fit the stub pipe (7) to the relief valve (5), sloping evenly downwards, protected from ice and open to the atmosphere: it may drip.
  5. Open the hot taps and start the water pump to push the air out; close the taps when air-free water flows. Check all joints.

Power Supply and Thermostat

  • AC power cable supplied (brown live, blue neutral, yellow/green earth). Fit a double pole switch and a suitably rated fuse; at least 3 mm insulation between contacts; follow national wiring standards.
  • Never run the electric element unless the tank is full of water: the element is permanently damaged.
  • Thermostat: standard setting 60°C. Power off, remove the protection cover (12) to reach the thermostat (10), turn the knob with a screwdriver, refit the cover and power on. It regulates the temperature only when heating electrically.
  • Over-temperature: the double thermostat with manual reset cuts the power. Power off, remove the cover (12), press the reset button, refit the cover and power on. If it trips repeatedly, call a Quick service centre.
  • A damaged power cable must be replaced by a Quick service centre; opening the unit without authorisation voids the warranty.

Maintenance

  • Check the magnesium anode (A) every 12 months; replace it if significantly reduced.
  • In winter, if unused, drain the heater with the lever of the valve (5) to avoid freezing damage.
  • Operate the overpressure release device regularly to clear calcium deposits and make sure it is not blocked.
  • Periodically check water joints, securing screws (replace if worn or corroded) and the electrical system.

Spare Parts

Quick BXS 25-40 water heater exploded view with position numbers

Code Pos. Description
SAMLB25320S0 1A Tank 25l Ask us to source it →
SAMLB40360S0 1B Tank 40l Ask us to source it →
PECRBLRS0000 2 Red plastic washer Ask us to source it →
PECRBLBNC000 3 White plastic washer Ask us to source it →
PECRBLBL0000 4 Blue plastic washer Ask us to source it →
MNVALS12S68P 5 Relief/non return valve Ask us to source it →
PBF25100W000 6 Hose clamp Ask us to source it →
PVTBGM10NT00 7 Discharge pipe Ask us to source it →
PGGRES000000 8A Element gasket from S/N 100.000 Ask us to source it →
PGRM43500000 8B Element gasket from S/N 200.000 Ask us to source it →
EVR12220N000 9A Electric element 1200W 220V Ask us to source it →
EVR05220N000 9B Electric element 500W 220V Ask us to source it →
EVR12110N000 9C Electric element 1200W 110V Ask us to source it →
EVR06110N000 9D Electric element 600W 110V Ask us to source it →
EVT15S000000 10 Bi-thermostat Ask us to source it →
ECC30150G000 11 Power supply cable Ask us to source it →
PECRB2200000 12A Boiler resistor cover 220V Ask us to source it →
PECRB1100000 12B Boiler resistor cover 110V Ask us to source it →
MBD04MXEN000 13 Nut Ask us to source it →
ESCL04000000 14 Ground cable terminal Ask us to source it →
MBR04X000000 15 Washer Ask us to source it →
MBV02919AXCC 16 Screw 2,9 x 19 Ask us to source it →

Dimensions

mm (inch); the letters refer to the drawing in the PDF.

Model A B C D E F G
BXS 25 370 (14" 9/16) 440 (17" 21/64) 460 (18" 7/64) 480 (18" 57/64) 330 (12" 63/64) 138 (5" 7/16) 55 (2" 3/16)
BXS 40 445 (17" 33/64) 520 (20" 15/32) 540 (21" 1/4) 560 (22" 3/64) 380 (14" 31/32) 146 (5" 3/4) 60 (2" 3/8)
Model H I L M N O
BXS 25 68 (2" 43/64) 76 (2" 63/64) 68 (2" 43/64) 330 (12" 63/64) 59 (2" 21/64) 305 (12")
BXS 40 90 (3" 1/2) 76 (2" 63/64) 90 (3" 1/2) 380 (14" 61/64) 50 (4" 31/32, as printed) 343 (13" 1/2)

Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.

Products in this Manual