Quick Marina XP square LED down light technical sheets (FP OD, FP SD, HP and LP, 4W and 6W): cut-out, recess, current draw, output and fitting.

Quick Marina XP LED Down Lights — Technical Sheets

Range at a Glance

Model Power Supply Current Size Mounting hole Recess IP Fixing Installation
Marina XP FP OD 4W 4 W 9-32 Vdc 0,33A@12V / 0,17A@24V 79 x 79 mm Ø 65 mm 30 mm IP66 Springs Ceiling
Marina XP FP OD 6W 6 W 9-32 Vdc 0,5A@12V / 0,25A@24V 79 x 79 mm Ø 65 mm 30 mm IP66 Springs Ceiling
Marina XP FP SD 4W 4 W 9-32 Vdc 0,33A@12V / 0,17A@24V 79 x 79 mm Ø 65 mm 30 mm IP66 Springs Ceiling
Marina XP FP SD 6W 6 W 9-32 Vdc 0,5A@12V / 0,25A@24V 79 x 79 mm Ø 65 mm 30 mm IP66 Springs Ceiling
Marina XP HP 4W 4 W 9-32 Vdc 0,33A@12V / 0,17A@24V 79 x 79 mm Ø 65 mm 28 mm IP66 Screws Ceiling
Marina XP HP 6W 6 W 9-32 Vdc 0,5A@12V / 0,25A@24V 79 x 79 mm Ø 65 mm 28 mm IP66 Screws Ceiling
Marina XP LP 4W 4 W 9-32 Vdc 0,33A@12V / 0,17A@24V 79 x 79 mm Ø 65 mm 30 mm IP66 Springs Ceiling
Marina XP LP 6W 6 W 9-32 Vdc 0,5A@12V / 0,25A@24V 79 x 79 mm Ø 65 mm 30 mm IP66 Springs Ceiling
  • Square 79 x 79 mm bezel in AISI 316L stainless steel. Finishes: polished / white / satin / black (HP: polished / white 9010 / satin / gold PVD / black).
  • Bicolor with 0,3 W secondary light power. Dimmable (PWM); recommended dimmer on the sheets: FASP094CA2A3D00 HDIM300 D00.

Photometric Data

Model Light source Light type Warm white (2900–3100 K) Day light (3800–4100 K) Beam angle
Marina XP FP OD 4W 1 power LED Bicolor 262 lm 293 lm 100°
Marina XP FP OD 6W 1 power LED Bicolor 338 lm 362 lm 100°
Marina XP FP SD 4W 1 power LED Bicolor 313 lm 345 lm 80°
Marina XP FP SD 6W 1 power LED Bicolor 393 lm 435 lm 80°
Marina XP HP 4W 1 high luminosity LED Bicolor 313 lm 345 lm 80°
Marina XP HP 6W 1 high luminosity LED Bicolor 393 lm 435 lm 80°
Marina XP LP 4W 1 power LED Bicolor 313 lm 345 lm 80°
Marina XP LP 6W 1 power LED Bicolor 393 lm 435 lm 80°

Luminous flux and beam angle as printed on each sheet.

Spring Mounted (FP, LP)

  1. Cut the hole to the size in the table.
  2. Bring the wires from the power supply to the panel or ceiling.
  3. Connect: red is positive, black is negative.
  4. Position the springs as shown on the sheet so the light enters the hole.
  5. Push the light body in, turning it to the desired position.

Wiring

  • Use the unit in ultra-low voltage (SELV) with a constant-voltage LED power supply. Do not connect directly to the mains (AC).
  • More than one light: connect them in parallel. The power supply must deliver a wattage equal to or higher than the total of the lights connected.
  • Positive is the red wire, negative is the black wire.

HP versions are screw-fixed with a 28 mm recess in the same Ø 65 mm cut-out.

Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.