INSTRUCTIONS

Installation and connection instructions for the Quick Maxibar linear LED light (12V and 24V): flush-mount slot size, wiring and power supply sizing.

DocumentQuick Maxibar Linear LED Light Installation Instructions
FormatPDF · 2 pages · 0.8 MB
LanguageEnglish
Quick Maxibar Linear LED Light — Installation Instructions

Models

Model Power Power supply
Maxibar 12V 18W/m 10–15Vdc
Maxibar 24V 18W/m 20–30Vdc
  • For the 12V model use a 12Vdc driver.
  • The LED lamps are built in and cannot be replaced.

Flush Mounting

The wires from the constant-voltage power supply (voltage as in the chart) must be present in the panel.

  1. Cut a slot 30 mm wide and 31,5 mm deep in the panel.
  2. Fit the support into the slot, drill and fix it with self-tapping screws (not supplied).
  3. Connect the power cables from the panel to the light bar cables: positive to red, negative to black. Test the light.
  4. Lay the cables in the support raceway.
  5. Press the bar into the support.
  6. The light bar must end up flush with the surface.

Wiring & Power Supply

  • Do not connect directly to the mains. A constant-voltage power supply is needed; its wattage must be equal to or higher than the total of the bars connected.
  • Several bars are connected in parallel. Example from Quick: three 1 m bars at 18W/m, 24V, on one Quick PSCV 60W 24V constant-voltage power supply.
  • Non-Quick power supplies may have a higher or lower inrush-current protection threshold, so the load may need different sizing because of the inrush current of the LED board at switch-on.

Maintenance

  • Clean with a soft damp cloth. Do not use chlorine-based sanitisers or degreasers; rinse with plenty of fresh water afterwards.
  • The LED lamps are built in and cannot be replaced.

Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.