INSTALLATION MANUAL

Installation and use of the Quick MC²X R5 QNC 5" touch-screen remote control for MC²X gyro stabilizers: panel cut-out, wiring, home page, eco and safe modes, alarms and the mandatory maintenance lockout.

DocumentQuick MC² R5 QNC Remote Control Panel Installation & Use Manual
FormatPDF · 52 pages · 8.9 MB
LanguageEnglish
Quick MC² R5 QNC Remote Control Panel — Installation & Use Manual

Technical Data

MC2X R5 QNC
Display 5" TFT, 800X480, 24 bit colours, white LED backlight, capacitive multi-touch
Interfaces 1 Ethernet 10/100 Mbit with integrated switch; 1 USB 2.0 (optional); RS-232/422/485 serial; 1 CAN port (1 MB)
Supply 9÷32 VDC (wiring diagram)
Fuse 12V → 2A, 24V → 1A
Operating / storage temperature 0 ÷ +50°C / –20° ÷ +70°C
Protection IP67 front and rear
Dimensions Front 159 x 115 mm, 49 mm overall depth; drilling template: four Ø 11,5 mm holes on 139,8 x 96,2 mm centres around the central opening
Standards EN 60945-2002 (EMC), RoHS 2011/65/EU, EN 60529-2004, ISO7637-1/2
  • It switches the stabilizer on and off, turns precession on and off and shows status, roll and precession angle, connected over CAN-BUS. Several panels can work as master and slaves (multi-display, multi-gyro).
  • In the box: R5 QNC touch 5" panel, protective cover, power and I/O cable (1 m / 3,28 ft), CAN BUS adapter cable (0,5 mt / 1,64 ft), J3 CAN BUS extension M/M (12 mt / 39,37 ft), CAN T 5P F/F/F connector, CAN terminator M, adhesive gasket, 2 fixing screws, 2 fixing brackets, drilling template, manual.

Mounting the Panel

  • Choose a clean, flat spot the operator can reach easily, with rear access and space for the connectors; the back must stay dry. Drilling must not weaken the structure.
  • Keep it at least 25 cm from the compass (printed "bush"), 50 cm from radio receivers, 1 m from radio transmitters and 2 m from the radar beam.
  • Tape the drilling template in place (it is the last page of the manual: print at 100% and check the 100 mm / 4" scale bar). Drill four Ø 11.5 mm holes for the bushes and cut the central opening; deburr. An inaccurate cut spoils the gasket seal.
  • Fit the adhesive gasket (not below 18°C) adhesive side up on the instrument, screw the 4 stud bolts into the bushes, fit the panel and secure from behind with shaped washers, growers and nuts. Panel up to 10 mm thick: washer flaps up; thicker than 10 mm: flaps down.
  • Peel off the protective film at the end.

Electrical Connection

  • Keep cables 1 m from radio cables (2 m from SSB).
  • Fit an easily reached on/off switch and a 4A fast-blow fuse on the supply line; size cables for their length; do not power it from the engine starting batteries.
  • CAN extensions must not exceed 100 meters in total. Push the female connectors on and tighten the ring nuts fully.
  • Single panel: supply cable 9÷32 VDC, CAN BUS adapter, CAN T connector, CAN M/M extension to the inverter (J3), terminators as shown. Quick suggests cutting power to the display when the driver is not powered.
  • Multi-display / multi-gyro: master and slave panels linked by Ethernet (an Ethernet switch 10/100 Mbps is needed for multi-gyro, not included).
  • While under way with the flywheel at full speed, do not cut the power: it would interrupt the precession control. On a power cut both stabilizer and panel switch off after 5 seconds and restart with the initial settings when power returns.

Using the Panel

  • At power-up the panel loads its programme (about 2 minutes – do not disconnect it), then touch the screen to reach HOME: status, flywheel speed percentage and natural / controlled precession angle.
  • ON/OFF switches the stabilizer only. Precession can be used only with the stabilizer on: it switches on automatically at 80% speed and off below 50%; you can switch it off at any time, and for safety it switches back on automatically after 15 minutes.
  • Status: OFF (flywheel may still turn below 35 rpm), READY, SPOOLING UP, HIGH SEAS (protection mode for sea state), SPOOLING DOWN.
  • Eco mode (user): two levels that reduce generator load on 90–260 Vac gyros or extend battery time on 12 Vdc gyros, with a possible slight loss of performance; switching takes about 5 seconds. The R4-driver edition gives up to 20%.
  • Safe mode (automatic, multi-gyro only): keeps the system running at reduced performance when one gyro, its panel or its driver fails, is off or is in a different state.
  • Setup User: brightness, alarm buzzer, units, language, day/night. Service page: speed, DC bus voltage, power, bearing and inverter temperatures, working hours. Commissioning, Setup and Factory pages are for Quick personnel.

Alarms

A flashing red alarm icon opens the Active Alarms page (history can be scrolled). On these alarms precession stops and the flywheel slows to a stop while the panel stays on; it all restarts when the fault clears.

Alarm Problem What to check
Input voltage too low / PFC fault Power supply issue Shore / generator voltage: minimum higher than 90VAC or 200VAC depending on model
Input current too high Motor current limit reached Motor power cables, motor sensor calibration, or Quick Service
Motor current too high / Input overvoltage Motor current regulation failed Motor power cables, motor sensor calibration, or Quick Service
Start of the motor failed The motor can't start J1 cable, motor sensor calibration, or Quick Service
External enable input / Communication error RC and driver can't communicate Power on the driver; J3 cable
Can bus watchdog fault / Precession sensor fault Internal error Contact Quick Service
Driver fault Driver doesn't work Driver and its LED; repair/replace; Quick Service
Position sensor value out of range Flywheel speed/position control failed J1 cable, or Quick Service
Overtemperature inverter Driver at maximum temperature (ambient >55°C) Ambient temperature at the driver (driver must be installed vertically)
Overtemperature motor Gyro bearing/motor at maximum temperature (ambient >55°C, bearing >90°C) Ambient temperature at the gyro; bearing with bearing checker
Temperature limit Gyro bearing/motor at maximum temperature (ambient >55°C, bearing >100°C) Ambient temperature at the gyro; bearing with bearing checker

Before any work, disconnect the stabilizer and make sure the flywheel has stopped completely: a spinning flywheel keeps generating current.

Maintenance & Technical Lockout

  • Scheduled maintenance by authorised Quick personnel is mandatory after 1 year from activation or 1000 hours of bearing operation, whichever comes first; a pop-up warns from the 12th month or 900h. The wrench icon stays until the service is done.
  • If it is not done the flywheel speed is reduced: 13th month / 900h warning only; 14th month / 1000h – 20% reduction; 15th month / 1050h – 70%; 16th month / 1100h – 100%, not running. Only a Quick service centre can restore it, and missed maintenance voids the warranty.
  • The R4-driver edition lists bearing, inverter and precession checks every 1000 hours by Quick service.
  • Clean without solvents or fuels; do not remove the safety labels.