INSTALLATION MANUALTechnical data, dimensions, installation of the reel (PTR) and strap (PTG) versions on deck or on a wall, wiring with the recommended controls, care and the parts list for the Quick Pontoon PT 350, 700 and 1000 on-deck windlasses.
DocumentQuick Pontoon PT 350, 700 & 1000 On-Deck Windlass Installation & User's Manual
FormatPDF · 56 pages · 5.0 MB
LanguageEnglish
Technical Data
The model number is not the motor output: PT 350 = 150 W, PT 700 = 250 W, PT 1000 = 350 W. R = reel (anchor rode), G = flat strap (lifting a tender).
|
PT 350 R / PT 350 G |
PT 700 R / PT 700 G |
PT 1000 R / PT 1000 G |
| Motor output |
150 W |
250 W |
350 W |
| Supply voltage |
12 V |
12 V |
24 V |
| Maximum pull |
260 kg 573,2 lb
|
600 kg 1322,7 lb
|
750 kg 1653,4 lb
|
| Maximum working load |
100 kg 220,4 lb
|
220 kg 485,0 lb
|
250 kg 551,0 lb
|
| Working load |
40 kg 88,1 lb
|
80 kg 176,3 lb
|
100 kg 220,4 lb
|
| Current at working load (1) |
13 A |
22 A |
16 A |
| Maximum chain speed (2) |
20,8 m/min 68,2 ft/min
|
20,8 m/min 68,2 ft/min
|
21,5 m/min 70,5 ft/min
|
| Chain speed at working load (2) |
19,3 m/min 63,3 ft/min
|
18,1 m/min 59,3 ft/min
|
18,3 m/min 60,0 ft/min
|
| Motor cable size (3) |
10 mm² (AWG 7) |
10 mm² (AWG 7) |
10 mm² (AWG 7) |
| Protection circuit breaker (4) |
20 A |
30 A |
20 A |
| Weight |
10 kg 22 lb
|
10,2 kg 22,4 lb
|
10,2 kg 22,4 lb
|
Deck thickness: 20 ÷ 40 mm (3/4" ÷ 1" 9/16). (1) After an initial period of use. (2) Measured with 6 mm rope. (3) Minimum value for a total cable length L ≤ 20 m; size the cable for the actual run. (4) DC circuit breaker, delayed-action (thermal-magnetic or hydraulic-magnetic). Studs for thicker decks on request.
Dimensions mm (inch)
- PT R and PT G: 294 (11 37/64), 173 (6 13/16) and 220 (8 43/64).
- PTR with the bow-roller accessory (as printed: only models 350 – 1000): 596 (23 29/64) overall length; other dimensions 308 (12 9/64), 231 (9 7/64), 148 (5 53/64), 220 (8 43/64).
Electrical System
-
PT 350 R / PT 350 G: the reversing contactor is integrated; wire battery → hydraulic-magnetic circuit breaker → windlass. Cable size is for L = L1 + L2 + L3.
-
PT 700 / PT 1000 (R and G): a separate reversing contactor unit is supplied, shown as mod. T6411-12 (12V) in the diagrams (also for the 24 V PT 1000, as printed). Cable size is for L = L1 + L2 + L3 + L4 + L5. Install the contactor away from water.
- Control circuit fuse: 4 A (12 V), 2 A (24 V).
- Recommended Quick accessories: RL control board (mod. 800 – WCS 810), watertight hand-held remote HRC1002, foot switch (mod. 900, 900U/900D), strap-roller with spring catch (PTG only), hydraulic-magnetic circuit breaker, chain counter CHC 1102 M, RRC radio control (R02, P02, H02).
- Fit at least two controls, so the windlass can still be run if one is damaged. View HRC 1002 →
Before You Drill
- In the box: PTR or PTG windlass, reversing contactor unit (700/1000 only), 30 m (98 ft) Dyneema "chain" (PTR only, as printed), drill template, bolts and screws, manual, warranty.
- Tools: Ø 9 mm (23/64") and Ø 15 mm (63/64", as printed) drill bits; 13 mm hex wrench.
-
PTG: align the flat strap (the windlass centre) with the hook of the tender to be lifted.
-
PTR: align the reel with the bow roller; the roller must lean out past the bow (or stern) so the anchor runs up and down without obstruction.
- Upper and lower deck faces as parallel as possible, or the installation may be unsafe; deck thickness within the table range, otherwise consult a Quick dealer.
Fitting Procedure
- Choose on-deck or wall mounting, then drill with the drill template.
- Open the passage, then finish and seal it (marine paint, gel coat or two-pack epoxy).
- Position the windlass with a clear run for the power and control cables, and screw the studs into it.
- Connect the windlass cables to the reversing contactor unit, or to the battery where the contactor is integrated.
Safety and Maintenance
- The PT is built to weigh the anchor; it is not designed for storm loads. Switch it off when not in use and check for swimmers before dropping anchor.
- At anchor, make the rope fast to a stopper or bollard; the windlass must not be the only securing device. Under way, switch the breaker off and secure the rope.
- Switch off the motor power before any manual work and take the rope off the reel.
- Wash salt deposits off with fresh water regularly.

Parts List
| Pos. |
Description |
| 1 |
Screw |
| 2 |
Windlass casing "PT Plast" series |
| 3 |
Plug |
| 4 |
Nut |
| 5 |
Washer |
| 6 |
Gear Z100 M1.5 |
| 7 |
Gear Z20 M1.5 |
| 8 |
Gear Z80 M1 |
| 9 |
Gear Z16 M1 |
| 10 |
PT spacer |
| 11 |
Internal circlip |
| 12 |
Bearing |
| 13 |
External circlip |
| 14 |
Internal circlip |
| 15 |
Bearing |
| 16 |
Screw |
| 17 |
Screw |
| 18 |
Windlass base PT series |
| 19 |
Plug L |
| 20 |
Oil seal |
| 21 |
Windlass extruded PT series |
| 22 |
Cable outlet PT |
| 23 |
Shaft PT 1 series |
| 24 |
Shaft PT 2 series |
| 25 |
Shaft PT 3 series |
| 26A |
Windlass motor 150W 12V PT |
| 26B |
Windlass motor 250W 12V PT |
| 26C |
Windlass motor 350W 24V PT |
| 27 |
Nut |
| 28 |
Screw |
| 29 |
Windlass reel "PT Plast" series |
| 30 |
Windlass base PT series |
| 31 |
Microswitch button 16A/250W |
| 32 |
Reversing contactor card 45A |
| 33 |
Screw |
| 34 |
Gear Z100 M1 |
| 35 |
Gear Z20 M1 |
| 36 |
Complete bow roller PT stainless steel |
| 37 |
Screw |
| 38 |
Screw |
| 39 |
Cover base PT series stainless steel |
The parts list gives descriptions only; ask us with the model (PT 350, 700 or 1000, R or G) and the serial number on the product label.
Drill Template
The Pontoon series drilling template (PTR 350/700/1000) is in the downloads, with the Ø 9 mm stud holes and the cut-out. Print it at 100% and check the 100 mm reference line before drilling.
Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.
Products in this Manual