INSTALLATION MANUAL

Installation of the Quick Q NCG-V B00 gateway that lets a Volvo Penta control system drive one BT QSY or BTQ (with MSC) thruster on the Quick "Q Centric" network: Volvo Penta requirements, wiring, status LED and technical data.

DocumentQuick Q NCG-V B00 Gateway Installation Manual
FormatPDF · 52 pages · 4.2 MB
LanguageEnglish
Quick Q NCG-V B00 Gateway — Installation Manual

What It Does & Requirements

  • Lets Volvo Penta control systems command ONE BT QSY or BTQ (with MSC) thruster on the "Q Centric" network.
  • Isolated OEM CAN bus interface with isolated OEM network supply, integrated 120Ω termination, N2K-compliant pinout on the OEM connector; firmware update via USB-C; 12/24 Vdc supply.
  • In the box: gateway, Volvo Penta OEM network NCG adapter cable, manual and warranty.
Volvo Penta requirement
System Volvo Penta Assisted Docking for DPI and IPS (10, 15, 20 and 30); Volvo Penta Joystick Docking for single DPI engine installation
Hardware Part Number 24510291 – CONVERTER, THRUSTER CONTROL MODULE (THCM)
Software Quick proportional thrusters supported from EVC2.0 25W49; THCM software 24972444, loaded from the VMM during an Autoconfig in EVC (the THCM ships with older software). Older boats: update EVC2 with the VODIA aftermarket tool.

Mounting & Wiring

  • Mount near the OEM system's communication control unit, accessible for maintenance, on a smooth, level surface with room above the front for the connectors.
  • Fix with 4 flat-head screws under 4 mm (not supplied): Ø 2.5 mm pilot holes in fibreglass, 4 M4 flat-head screws on metal. Do not overtighten.
  • At least 25 cm from the compass, 50 cm from radio receivers, 1 m from radio transmitters (except SSB), 2 m from SSB transmitters and the radar beam; cables 1 m from radio signal cables and 2 m from SSB transmitter cables.
  • Q NETWORK: plug in the drop cable from the "Q Centric" network (max 5 m).
  • OEM NETWORK: plug in the M12 female end of the supplied adapter cable; its other end goes to the Volvo Penta Thruster Control Module P/N 24510291. OEM connector pins: VCC, GND, CAN H, CAN L.
  • Check all connections before powering up.

Status LED

LED Meaning
Off Not powered
Steady green Powered, no problems
Steady orange Low supply: below 9.5 V (clears above 10 V)
Orange, 1 repeated flash OEM network not connected (normal if the OEM system is off or disabled)
Orange, 2 repeated flashes "Q Centric" network not connected – check its connections
Orange, 3 repeated flashes Neither network connected
Red, flashing very fast CRC error flash: firmware corrupted – contact Quick
Red, flashing fast EEPROM CRC error: disconnect the power; at restart factory settings are restored

Maintenance: none special. Disconnect power, then clean the front with a soft cloth dampened with water; no chemicals.

Technical Data

Supply voltage from 9 to 32 Vdc
Maximum current absorption 500 mA @ 9 Vdc
OEM bus supply 12 Vdc, 220 mA max
Termination resistor 120 Ω
Operating temperature from -20 °C to +70 °C
Protection rating IP67
Communication interface 2x CAN bus
Weight 200 g
EMC class EN 60945 - FCC PART 15 rules 47