INSTALLATION MANUAL
Installation and connection of the Quick QNN-DRV 4CH 700 (tunable white) and QNN-DRV 4CH 350 (RGBW) LED downlight drivers controlled by the LDIM BUS RGBW gateway, with the list of compatible QCC/QNN downlights and their cut-outs.
DocumentQuick QNN-DRV RGBW/TW LED Drivers User Manual
FormatPDF · 28 pages · 3.9 MB
LanguageEnglish

The Two Drivers
| QNN-DRV 4CH 700 | QNN-DRV 4CH 350 | |
|---|---|---|
| Drives | Tunable white (TW) and white single-colour downlights | RGBW downlights |
| Output | 4 channels constant current, 700 mA max each | 4 channels constant current, 350 mA max each |
| Max load | 3 x 6W TW @ 12V; 6 x 6W TW @ 24V; 3 x 12W TW @ 24V | 3 x 6W RGBW @ 12V; 6 x 6W RGBW @ 24V; 3 x 12W RGBW @ 24V |
| Input | Power and control from the LDIM BUS RGBW through a 5-pole connector | 5 constant voltage cables 10 ÷ 30 Vdc from the LDIM BUS RGBW |
| Operating / storage temperature | +5°C to +50°C / –40°C to +70°C | +5°C to +50°C / –40°C to +70°C |
| Humidity / housing | 80% non-condensing / IP20, SELV | 80% non-condensing / IP20, SELV |
| In the box | Driver, 2 input connectors, RJ45 line terminator, warranty, manual | Driver, 2 input connectors, RJ45 line terminator, warranty, manual |
The module only works when coupled and correctly connected to a Quick LDIM BUS RGBW. The cover pages print "driver costant voltage", while the manuals describe constant-current outputs.
Mounting & Wiring
- Mounts on a DIN rail; install on a vertical surface for ventilation, inside a protected distribution panel that unauthorised people cannot reach, away from rain, dust and humidity.
- Always fit a fast-acting 3A fuse on the driver supply. Disconnect the power before installing or servicing.
- Control signal cable (5-pole connector): max 100 metres (328'), max cross section 2.5mm².
- Driver to lights: shielded CAT5e (FTP) Ethernet cable with RJ-45 male-to-male connectors (not supplied), max 25 metres (82') with RJ45 extensions; close the line with the RJ45 terminator.
- Cleaning: damp cloth on the front only, no corrosive substances, no liquids on the unit; power off first.
Fitting the Downlights
- Drill the hole given in the table for your downlight.
- Connect it as in the wiring diagram and test that it works.
- Spring models: position the springs as shown and push the light into the hole. Screw models: fix it to the panel with self-tapping screws (not supplied).
- Press the frame onto the light. On the Chiara QNN the frame screws on clockwise.
Compatible QCC/QNN Downlights
| Model | Hole | Model | Hole |
|---|---|---|---|
| Kor XP LP 6W QCC/QNN | Ø 65 mm | Danae LP 6W QCC/QNN | 90x90 mm |
| Kor XP HP QCC/QNN | Ø 65 mm | Danae HP 6W QCC/QNN | 90x90 mm |
| Kai XP LP 6W QCC/QNN | Ø 65 mm | Danae LP 12W QCC/QNN | 90x90 mm |
| Kai XP HP QCC/QNN | Ø 65 mm | Danae HP 12W QCC/QNN | 90x90 mm |
| Blake XP LP QCC/QNN | Ø 65 mm | Cristian 6W QCC/QNN | Ø 89 mm |
| Blake XP HP QCC/QNN | Ø 65 mm | Cristian 12W QCC/QNN | Ø 89 mm |
| Marina XP LP QCC/QNN | Ø 65 mm | Kristine 6W QCC/QNN | 90x90 mm |
| Marina XP HP QCC/QNN | Ø 65 mm | Kristine 12W QCC/QNN | 90x90 mm |
| Apollo XP LP QCC/QNN | Ø 65 mm | Demetra 6W QCC/QNN | 85x85 mm |
| Apollo XP HP QCC/QNN | Ø 65 mm | Demetra 12W QCC/QNN | 85x85 mm |
| Daphne XP LP QCC/QNN | Ø 65 mm | Vanessa 6W QCC/QNN | 90x85 mm |
| Daphne XP HP QCC/QNN | Ø 65 mm | Vanessa 12W QCC/QNN | 90x85 mm |
| Zeus LP 6W QCC/QNN | Ø 89 mm | Venus 88 6W QCC/QNN | Ø 65 mm |
| Zeus HP 6W QCC/QNN | Ø 89 mm | Chiara QCC/QNN | Ø 65 mm |
| Zeus LP 12W QCC/QNN | Ø 89 mm | Zeus HP 12W QCC/QNN | Ø 89 mm |
Only the QCC/QNN versions of these lights work with these drivers; the standard versions are not listed.