INSTALLATION MANUAL

Part numbers, relay sizing, mounting with or without the guard, terminals and wiring for the Selden SEL-Bus emergency stop button and relay.

DocumentSelden SEL-Bus Emergency Stop & Relay Installation Manual
FormatPDF · 16 pages · 1.5 MB
LanguageEnglish
Selden SEL-Bus Emergency Stop & Relay — Installation Manual

What the Manual Covers

Part No. Description
540-648 Emergency stop button Ask us to source it →
540-649-01 Protective guard for emergency stop button Ask us to source it →
532-498 Relay 12V 100A Ask us to source it →
532-499 Relay 24V 100A Ask us to source it →
532-599 Relay 12/24V 250A Ask us to source it →

The relay switches the incoming power to the SEL-Bus PSU. Size it for voltage and load: 100A per PSU in a 12V installation, 50A per PSU at 24V.

Relay Voltage (V) Current (A) Power consumption (W)
532-498 12 100 6
532-499 24 100 6
532-599 12/24 250 3 (45 on start up)

With Protective Guard (recommended)

  1. Choose fasteners with a head smaller than Ø 9.5x4mm and thread smaller than Ø5mm (e.g. MLC6S M5, MRT M5).
  2. Drill the mounting holes.
  3. Attach the button to the guard.
  4. Connect the cables.
  5. Apply sealant in the grooves under the guard.
  6. Fasten button and guard.

Without Guard

  1. Max. mounting surface thickness 4mm; if thicker, make a 40mm countersink on the back.
  2. Drill the mounting hole.
  3. Fit the button with its nut.
  4. Connect the cables. On an uneven surface extra sealant may be needed.

Mount the button within easy reach whenever SEL-Bus devices are in use.

Terminals & Wiring

Unit Terminal Connector Use
Stop button 11 & 12 Blade receptacle 2.8x0.5mm Normally closed contact, to the relay
Stop button X1- & X2+ Blade receptacle 2.8x0.5mm Optional LED, 12-24V, best on the navigation light switch
Relay 532-498 / 532-499 30 & 87 Ring terminal, M6 Power terminals
Relay 532-498 / 532-499 85 & 86 Blade receptacle 6.8x0.8mm Control terminals, relay coil
Relay 532-599 +A1 & -A2 Ring terminal, M8 Power terminals
Relay 532-599 Red & black cables – Control terminals, relay coil
Relay Voltage (V) Fuse current rating (A) Min cable area (mm2)*
532-498 12 2 1
532-499 24 1 0.35
532-599 12 4 1
532-599 24 2 0.35
  • *Max. cable length 10m.
  • Recommended circuit: +12/24V from the fuse and battery disconnect switch, through the relay power terminals to PSU +; the stop button (11/12) in the relay coil circuit via its fuse.
  • A remote power switch can be added in the coil circuit (second wiring diagram in the PDF).
  • Warranty 2 years when installed, operated and maintained per the manual.

Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.