INSTRUCTIONS
Cable exit positions by mast section and the wiring routine for Selden spreader up-lights and down-lights.
DocumentSelden Spreader Up-lights & Down-lights Instructions
FormatPDF · 2 pages · 0.6 MB
LanguageEnglish

Side Position S
| Section | S | Section | S |
|---|---|---|---|
| F176 | B+25 | C156 | B-25 |
| F194 | B+28 | C175 | B-35 |
| F212 | B+30 | C193 | B-35 |
| F228 | B+28 | C211 | B-45 |
| F246 | B+24 | C227 | B-50 |
| F265 | B+26 | C245 | B-55 |
| F286 | B+24 | C264 | B-55 |
| F305 | B+24 | C285 | B-55 |
| F324 | B+35 | C304 | B-55 |
| R370 | B+45 | E321, E365 | B-55 |
Cut Outs
- Turn the mast side up.
- Drill a Ø 4,9 mm hole H=200 mm above the spreader height, side position S from the table.
- Enlarge to Ø 8,0mm and grind the hole inside and out.
- Repeat for each spreader, then make the same holes on the opposite side.
Running and Connecting the Cables
- Fit the cable conduit into the mast (see PHB 1025); mark the conduit through the Ø 8,0 mm exits.
- Pull the conduit out, cut ~ Ø 20 mm holes with a hole saw, grind, and push it back.
- Push a plastic rod up to the uppermost exit, attach the cable and pull it down to the extrusion end. For up- and down-light, use a cable with 3 wires to the first spreaders.
- Strap the cables, fit the rubber adapter and drill Ø 4,0 mm for its screws; connect two or three wires to the connector.
- Fasten the female terminals to the mast; fit the spreader, cut the light cable to length and connect the male terminal.
- Check colours match in male and female terminals. Mark the down-light wire with tape. Always use the blue wire as minus (-).
Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.