OWNER'S MANUAL

Approvals, fitting, harness use, inflation, re-arming kit numbers, the Harness Release System, maintenance and service-centre spares for the Spinlock Deckvest DURO+ 275N automatic or manual lifejacket with integrated deck harness.

DocumentSpinlock Deckvest DURO+ Owner's Manual
FormatPDF · 60 pages · 2.4 MB
LanguageEnglish
Spinlock Deckvest DURO+ — Owner's Manual

Approvals and Specifications

Item DURO+
Lifejacket EN ISO 12402-2 : 2020 – 275N; minimum buoyancy 275N (62lb)
Deck harness EN ISO 12401:2009, integrated
Manual version Also approved to ISO 12402-6 : 2020 – Special Application Lifejacket, user assisted PFD, manual only: the user must inflate it for flotation and face-up righting
Inflation system UML Pro Sensor Elite automatic firing head (or Pro Sensor Elite manual firing head), manual handle, oral tube
CO2 cylinder 60g
Size One size, chest 60 - 150cm
User Aged above 16 years and weighing not less than 50 kg
Temperature -30° C to +60° C

Options: sprayhood, Pylon light, Lume-On, HRS (Harness Release System), PLD. Spinlock does not service lifejackets more than 10 years old.

Features

  • Pylon light with a 23cm elevation, activated on contact with water (optional).
  • Sprayhood structured to stand free of the face (optional).
  • Back adjustment point for fit and to reduce pressure on the neck.
  • UML Pro Sensor Elite firing head with visual indicator showing the armed status of cylinder and head; indicator window on the rear.
  • Safety line attachment loop in high tensile fibre (lighter and quieter than steel D-rings); optional rear safety line attachment point.
  • Contoured crotch strap; chest pack attachment points; QBZ split zip for instant access to the oral tube; red lifting / buddy loop; whistle.
  • Lume-On illumination (optional): water activated, minimum 2hrs flashing at full intensity, 5 year shelf life.

Fitting

  1. Put on as a jacket.
  2. Fasten the buckle.
  3. Pull the chest belt webbing tight – it is unsafe to wear any lifejacket or harness loosely.
  4. Adjust the back strap so the chest belt sits above the lowest point of the rib cage.
  5. Pass the crotch strap through the legs before fastening the plastic buckle on the front; it can be stored in the rear pocket.

The crotch strap is recommended; the jacket is tested and approved without it at your own risk.

Using the Harness

  • Anchorage point is at the centre of the chest. Use an approved personal safety line only, with no sharp edges at the attachment point.
  • Attach to jack lines or fixed eyes able to withstand more than 1 tonne. Never attach to lifelines, standing or running rigging.
  • Harness and safety line prevent falling overboard; they give no protection against falls from height and can transmit very large forces.
  • After a major fall (full body weight dropped and stopped) do not continue to use the product.

Inflating

Method How
Manual Sharply pull the rubber handle downwards; the CO2 cylinder inflates the bladder within seconds.
Oral Open the zip at the yellow breakout point on the front panel, remove the end cap and blow until fully inflated.
Automatic Inflates within seconds of the inflator being submerged; the automatic capsule fires a sprung pin through the CO2 cylinder.

Below freezing a full cylinder may not inflate the jacket adequately: top up orally after the CO2 has discharged (not before). Firing the CO2 into a fully inflated jacket can over-pressurise and damage it.

Deflating and Testing

  • Deflate: invert the oral-tube end cap into the valve and gently squeeze out all air or gas; return the cap.
  • Test in shallow water just deep enough for your head to be above the surface: automatic inflation within five seconds of water contacting the firing head.
  • For an oral test remove cylinder and firing head first.
  • After testing deflate fully and dry the Deckvest thoroughly.

Re-arming and Repacking

  1. Remove the cylinder and old firing cap by unscrewing anti-clockwise.
  2. Check the firing mechanism moves freely and is free from contamination.
  3. Fit the new cap first, then the new cylinder, ensuring a secure fit. Only approved Spinlock Deckware re-arming kits should be used.
Part No. UML Pro Sensor Elite re-arm
DW-RAK/E275 Automatic version View kit →
DW-CYD60 Manual version View kit →

Repacking

  1. Deflate, separate the zip chain at the yellow end section, pull the zips out and re-attach them on the firing-head side; run the slider round to that side.
  2. Concertina the bladder onto itself and align the firing head over the indicator window; check the cylinder is tight and the firing cap secure, and that the manual cord is not caught.
  3. Sprayhood (if fitted) goes underneath the bladder: lay it out, fold the window into its pocket and concertina the rest.
  4. Concertina the top in, run the zip round to close, fasten the flap across the breakout point and tuck the zip ends inside the cover.

Harness Release System (Optional)

  • To release: pull the HRS handle cord only – the harness loop releases. Do not try to open it by rotating the lock with the handle.
  • Re-arming: push the harness loop ends through the cover around the black belt webbing; the top loop must always pass through the bottom loop.
  • Place the harness loop into the lock and use the handle to rotate the lock anticlockwise to the Locked position – do not over-rotate. Check the loop is secured and attach the handle to the press stud.
  • Retro-fitting (service guide): the original harness loop is cut out and cannot be replaced once cut. 2021 models onwards use a separate flap secured to the belt.
Part No. Description
DW-HRS/6D Harness Release System kit Ask us to source it →
DW-HRS/6D/STROP Strop only Ask us to source it →

Owner Checks

  • During use: check buckles and fastenings regularly.
  • Before and after use: look for damage, abrasion, wear, tear or contamination, especially stitching and webbing.
  • Annually: inspect the fabric; inflate orally until firm and leave 24hrs (any loss of firmness = leak, unsafe); check the oral valve under water; remove and inspect all components; make sure the CO2 cylinder is screwed in tight.
  • Spinlock recommends a service at least every two years by an approved service center; the inspection record in the manual is laid out for an inspection every 3 months.
  • Clean by hand with cylinder and automatic parts removed, fresh water max 30° C, dry in a cool ventilated dark room. Some dye may transfer when first used wet.

Service Centre Checks

  • Bladder test with clean dry air to approx. 2 psi (14 kPa), 24 hrs at stable temperature; more than approx. 10% softening = replace the bladder.
  • Firing mechanism tightened to the manifold at 3nm with a calibrated tool; new automatic cartridge with expiry at least 2 years away; both indicators green.
  • Cylinder: 60g for 275N; check label and weight; Spinlock fits yellow retainers to the cylinder on all 275N models – replace on service.
  • Corroded cylinder coating = replace. Jackets over 10 years old should not be serviced.

Spare Parts (Quick Service Guide, Deckvest 6D & DURO+)

Part No. Description
DW-BLD/275UML/2 Bladder, 275N Ask us to source it →
DW-UPS UML Pro Sensor Elite firing unit Ask us to source it →
DW-UMLE UML Pro Sensor Elite firing cap View part →
DW-SV06 Replacement cylinder O-ring, yellow UML Mk5 and Pro Sensor Ask us to source it →
DW-SV07 Spare oral tube cap Ask us to source it →
DW-BKL38 Crotch strap buckle, male Ask us to source it →
DW-ZPL Zip slider pack (pre 2022 dated products) Ask us to source it →
DW-PY/L1 Pylon replacement light, all Deckvest models View part →
DW-PCC Chest pack View part →

The 275N bladder is also listed with a fitted UML Pro Sensor Elite unit: DW-BLD/275UML/2 with DW-UPS/F. Service tools: DW-SV1, DW-SV2, DW-SV3. The service guide also covers fitting the Ocean Signal MOB 1 and PLB 3 and the Lume-On lights; it is for approved Deckvest service centres.

Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.

Products in this Manual