INSTALLATION MANUAL

How the Vetus BISEP19 bilge water/oil separator filters oil out of the bilge pump discharge, where to mount it, how to change the filter discs, and its service parts.

DocumentVetus Bilge Water/Oil Separator BISEP19 Installation Manual
FormatPDF · 28 pages · 2.3 MB
LanguageEnglish
Vetus Bilge Water/Oil Separator BISEP19 — Installation Manual

How It Works and Technical Data

  • Fitted in the bilge pump discharge line, the filter element (a mass of surface-treated fibres) absorbs and retains up to 95% of oils, fats and emulsions, and isolates heavy metals; it can be washed and reused after the oil is collected.
  • Heavily contaminated water holds 100 to 200 mg/l (100 to 200 ppm); the element handles up to 600 mg/l and absorbs approximately 600 g of oil – at an average 40mg/l that is about 15.000 liters of water.
  • Use a bilge pump of approximately 20l/min; two separators in parallel increase capacity. The separator adds resistance in the discharge line.
Item Value
Housing / cover Polypropylene GF / Styrol-Acrylnitril SAN (transparent)
Weight 0.45 kg (1 lb)
Max. ambient / water temperature 75 °C (170°F) / 55 °C (130°F)
Max. over pressure 0.5 bar (50 kPa, 4 psi)
Hose connection 19 mm (3/4")
Nominal bilge pump capacity 20 l/min (4.4 Imp.Gal., 5.3 US Gal.)
Back pressure at 20 l/min 140 mbar (14 kPa, 2 psi)
Absorption Oil and grease up to 95%, lead up to 88%, copper up to 71%, nickel up to 71%, zinc up to 57%
Dimensions ø148 (5 13/16"), height 163 (6 7/16"); 118, 77, 70, 50 and 9.5 mm as drawn

Mounting

  • Mount on a vertical bulkhead in an easily visible place, always above the waterline and high enough to stop bilge water running back or siphoning (installation examples show min. 30 cm (12")); allow for heel on a sailboat.
  • Use flexible 19 mm hose on both sides (pump to separator, separator to through-hull); fit with water or soap only, never oily products; stainless steel hose clamps.
  • With very long hose runs, fit a check valve just downstream of the bilge pump to stop it cycling on and off.

Changing the Filter

  1. Check the element regularly and replace it before it is saturated with oil.
  2. Unscrew the cap by turning the housing anticlockwise – by hand only, never with tools.
  3. Take out the 15 loose discs one by one, clean the housing and insert the new discs one by one.
  4. Grease the O-ring (silicone oil or PTFE spray), refit the cap by hand and check the seal: a badly closed cover lets bilge water escape past the O-ring.
  5. Before frost, drain the separator by removing the hose couplings (there is no drain valve).

Service Parts

Vetus BISEP19 service parts drawing

Part Pos. Description
BISEP19F2 1 Filter material (15x) Ask us to source it →
FTR3302 2 Set: o-ring (5x) View part →

Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.