OWNER'S MANUAL

Engine room layout, mounting, ducting, wiring and technical data for the Vetus VENT76A and VENT102 extractor fans (3" and 4", 12 or 24 V).

DocumentVetus Extractor Fans VENT76A, VENT102 Installation & User Manual
FormatPDF · 20 pages · 3.1 MB
LanguageEnglish
Vetus Extractor Fans VENT76A, VENT102 — Installation & User Manual

Technical Data

Type VENT76_A VENT102_
Motor 12 V or 24 V direct current 12 V or 24 V direct current
Speed 4800 rpm 4800 rpm
Current Max. 8 A for 12 V; 4 A for 24 V Max. 9 A for 12 V; 4.5 A for 24 V
Capacity Max. 4 m3/min (141 CFM) for 13.6 V Max. 8 m3/min (282 CFM) for 13.6 V
Duct connection ø 76 mm (3") ø 102 mm (4")
Weight 1.2 kg (2.65 lbs) 1.5 kg (3.30 lbs)
Ambient temperature Maximum 70 degrees C (158 degrees F) Maximum 70 degrees C (158 degrees F)

The motor is ignition protected, ISO8846. Optional mounting kits: VENTKITA (VENT76_A) and VENTKITB (VENT102_); dimensions in the PDF.

Engine Room Ventilation

  • For ventilating the engine room, toilet or galley. Not recommended for supplying air to the engine: engine suction makes the fan overspeed and overheat.
  • Engine without its own air inlet: ventilate only with the engine stopped. With a separate inlet (grille with plenum chamber): extract hot air with the engine running or stopped.
  • Diesel: air in low, extract high. Petrol: air in high, extract low (below the top of the engine bed) but clear of bilge water.

Installation and Wiring

  • Fit on a bulkhead or floor well above the bilge water, away from splashes, drips or deck wash water.
  • Use the fan as a template; drill for 4.8 mm (no. 10) screws; tighten evenly without splitting the mounting feet.
  • Duct internal diameter 76 mm (3") for VENT76_A or 102 mm (4") for VENT102_: smooth inside, resistant to at least 70º C (158 degrees F), water, oil, fuel and under/over-pressure; short with few, wide bends; stainless hose clamps. Without a duct, fit a grille.
  • Wire at least 2.5 mm2 (AWG 14). Medium time lag fuse in the + wire: VENT76_A 8 A @ 12 V / 4 A @ 24 V; VENT102_ 9 A @ 12 V / 4,5 A @ 24 V. Red +, black −.
  • Run the fan at least 4 minutes and check for vapour before starting the engine. NEVER switch it on while refuelling.

Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.