INSTALLATION MANUAL

Wiring diagrams for Vetus solenoid switches (relays) on anchor windlasses: single relays for series motors with two field coils, dual make/break relays for one-field-coil and permanent-magnet motors, and the interlock relays needed with two separate switches.

DocumentVetus Solenoid Switches (Relay) Installation Manual
FormatPDF · 4 pages · 0.3 MB
LanguageEnglish
Vetus Solenoid Switches (Relay) — Installation Manual

Which Relay for Which Motor

Relay Voltage Use (diagram)
AFST1512S 12V Single relay; series motor, 2 field coils (two relays: hauling in / letting go) View part →
AFST324S 24V Single relay; series motor, 2 field coils View part →
AFST624S 24 V Single relay; series motor, 2 field coils View part →
AFST1512D 12V Dual relay; series motor with 1 field coil, or permanent magnet motor View part →
AFST324D 24V Dual relay; series motor with 1 field coil, or permanent magnet motor View part →
AFST624D 24 V Dual relay (Hercules); series motor with 1 field coil, or permanent magnet motor View part →
STM9050 12 V Extra interlock relay when two separate switches are used View part →
STM3871 24 V Extra interlock relay when two separate switches are used Ask us to source it →

Older codes SOL1512S, SOL324S, SOL1512D and SOL324D appear alongside the AFST relays on the same diagrams. Windlass models on the diagrams: Hercules, Alexander III, Ajax, Tiger, Condor, Picus, Puma II, Achilles II, Titan. All relays IP66.

Wiring Diagram Legend

  • 1 battery, 2 fuse, 3 switch (hauling in), 4 switch (letting go), 5 solenoid switch (single relay), 6 windlass motor (series motor, 2 field coils), 7 solenoid switch AFST624S.
  • 8 solenoid switch (dual relay), 9 windlass motor (series motor, 1 field coil), 10 windlass motor (permanent magnet motor), 11 switch (hauling in and letting go), 12 solenoid switch STM9050 / STM3871.

The two motor relays (5) must never be switched on at the same time. This can happen when two separate switches (3, 4) are used for hauling in and letting go: in that case install 2 extra relays (12) as shown on the drawing.

Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.