OWNER'S MANUAL

Operation, automatic switch-off setting, thermal protection and dimensions of the Vetus BPAJ, BPAS, BPJR(C) and BPSR(C) on/off thruster panels, plus the wiring diagrams for remote control of a battery main switch and the BPAJ / BPAS drill pattern.

DocumentVetus Bow & Stern Thruster Control Panels BPAJ, BPAS, BPJR(C), BPSR(C) User Manual
FormatPDF · 2 pages · 0.5 MB
LanguageEnglish
Vetus Bow & Stern Thruster Control Panels BPAJ, BPAS, BPJR(C), BPSR(C) — User Manual

Use

  • Be careful: with 2 control panels installed, never operate the bow thruster from both panels at the same time.
  • Switch on the main switch, then press the on/off switch twice: after the first press the LED flashes blue and the buzzer sounds continuously; press again within 6 seconds. The LED stays blue and the buzzer gives (- . -).
  • The motor runs on the direction switch. Changing from port to starboard (or back) in one movement gives a delay of about 1.5 seconds so the motor stops before reversing.
  • Operating a direction switch for more than 2 minutes at a time switches the motor off: a warning (. - . . -) sounds while the switch is held and the LED flashes red for 5 seconds. Release it; once the LED is back to blue the motor can run again.
  • Switch off: press on/off once after use; the panel sounds (. . . - . -). Switch off the main switch when leaving the ship.

Automatic Switch-Off and Protection

  • Standard setting: the panel switches itself off 30 minutes after the direction switch was last used; this can be switched off (the panel then only switches off with the on/off button) and on again.
  • To change it: switch off the thruster power supply (battery main switch), hold the direction switch (or both) to starboard, switch the power back on and watch the LED(s): RED = automatic switch-off now OFF, BLUE = automatic switch-off now ON. Release the switch(es); the setting is kept when the power is switched off.
  • Thermal protection of the control current: on overload the panel sounds ( . - . . - ) once and the LED alternates red and blue for about 7 seconds; once the overload is solved the system works normally again.

Overall Dimensions

Panel Front In front of panel Behind panel Body Panel thickness
BPAJ (joystick) 97 × 94.5 mm (3 13/16" × 3 3/4") 62 mm (2 7/16") 89 mm (3 1/2") ø 52 mm (2 1/16") Min. 1,5 – max. 22 mm
BPAS (touch) 97 × 94.5 mm (3 13/16" × 3 3/4") 5 mm (3/16") 89 mm (3 1/2") ø 52 mm (2 1/16") Min. 1,5 – max. 22 mm
BPJR(C) (round joystick) ø 63.5 mm (2 1/2") 57 mm (2 1/4") 89 mm (3 1/2") ø 52 mm (2 1/16") Min. 1,5 – max. 22 mm
BPSR(C) (round push buttons) ø 63.5 mm (2 1/2") 11 mm (7/16") 89 mm (3 1/2") ø 52 mm (2 1/16") Min. 1,5 – max. 22 mm

BPAJ / BPAS drill pattern (scale 1:1): ø 52 mm (2 1/16") hole, plate 97 × 94.5 mm. Print at 100% and check the dimensions before drilling.

Wiring Diagrams (Negative Switching Relay as of 2023)

  • Remote control of a battery main switch through the thruster panel, 12 / 24 V.
  • BOW25 and BOW35, single battery and with a second battery and battery splitter.
  • BOW55, BOW60, BOW75, BOW95, BOW125, BOW160, BOW220 and BOW285 (48 V), single battery and with two batteries.
No. Wiring colour code
1 Blue
2 Red (+)
3 Black (-)
4 White
5 Grey

Legend: main fuse, main switch, control current fuse, solenoid switch, electric motor, control panel, battery, plug, socket, extension cable, alternator, thermal protection, fuse, battery splitter.