SELECTION GUIDEThrust, vessel size, tunnel, voltage, weight and battery data for the complete Sleipner DC thruster range: E-series and SE/SEP tunnel thrusters, ER and SR retractables, SX and EX externals, plus the control panels and remotes that run them.
DocumentSleipner DC Thrusters The Complete Range
FormatPDF · 2 pages · 1.1 MB
LanguageEnglish
Tunnel Thrusters
E-series (brushless)
| Model |
Thrust at 24/48V and 21/42V (kg) |
Ideal vessel size (m/ft) |
Tunnel ID (mm) |
Propeller |
Voltage (V) |
Weight (kg) |
| E30/125S |
30 |
6-8/20-28 |
125 |
Single |
12 |
TBD |
| E40/125S |
40 |
8-10.5/26-34 |
125 |
Single |
12 |
TBD |
| E50/140S |
50 |
8-11/27-37 |
140 |
Single |
12/24 |
TBD |
| E60/185S |
60 |
8-11/27-37 |
185 |
Single |
12/24 |
TBD |
| E80/185TC |
80 |
10-15/35-48 |
185 |
Twin Counter |
12/24 |
TBD |
| E95/185TC |
95 |
12-17/35-55 |
185 |
Twin Counter |
12/24 |
TBD |
| E100/185T |
100 |
12-17/35-55 |
185 |
Twin |
24/48 |
25 |
| E120/215T |
120 |
14-20/44-64 |
215 |
Twin |
24/48 |
27 |
| E130/250T |
130 |
13-19/42-63 |
250 |
Twin |
24/48 |
29 |
| E150/215T |
150 |
14-20/44-64 |
215 |
Twin |
24/48 |
27 |
| E170/250TC |
170 |
15-22/50-70 |
250 |
Twin Counter |
24/48 |
30 |
| E210/250TC |
210 |
17-24/55-78 |
250 |
Twin Counter |
24/48 |
37 |
| E240/250TC |
240 |
17-24/55-78 |
250 |
Twin Counter |
48 |
37 |
| E250/300TC |
250 |
22-30/72-100 |
300 |
Twin Counter |
24/48 |
43 |
| E300/300TC |
300 |
22-30/72-100 |
300 |
Twin Counter |
48 |
43 |
| E340/300TC |
340 |
19-30/62-98 |
300 |
Twin Counter |
48 |
43 |
SE / SEP (PRO)
| Model |
Voltage |
Thrust at 12/24V (kg) |
Thrust at 10.5/21V (kg) |
Ideal vessel size (m/ft) |
Tunnel ID (mm) |
Propeller |
Min. battery CCA (DIN) |
| SE20 / SEP20 |
12V |
25 |
20 |
>7/23 (as printed) |
110 |
Single |
200 |
| SE25 / SEP25 |
12V |
30 |
25 |
>7/24 (as printed) |
110 |
Single |
200 |
| SE30 / SEP30 |
12V |
40 |
30 |
6-8/20-28 |
125 |
Single |
200 |
| SE40 / SEP40 |
12V |
48 |
40 |
8-10.5/26-34 |
125 |
Single |
300 |
| SE50 / SEP50 |
12V / 24V |
62 |
50 |
8-11/27-37 |
140 |
Single |
350 / 175 |
| SE60 / SEP60 |
12V / 24V |
73 |
60 |
8-11/27-37 |
185 |
Single |
350 / 175 |
| SE80 / SEP80 |
12V / 24V |
96 |
80 |
10-15/35-48 |
185 |
Twin |
550 / 300 |
| SE100 / SEP100 |
12V / 24V |
116 |
100 |
12-17/35-55 |
185 |
Twin |
750 / 400 |
| SE120 / SEP120 |
24V |
139 |
120 |
13-18/42-60 |
215 |
Twin |
450 |
| SE130 / SEP130 |
12V / 24V |
160 |
130 |
13-19/42-62 |
250 |
Twin |
750 / 400 |
| SE150 |
24V |
182 |
150 |
14-20/44-64 |
215 |
Twin |
560 |
| SE170 |
24V |
210 |
170 |
15-22/50-70 |
250 |
Twin Counter |
560 |
| SE210 |
24V |
250 |
210 |
17-24/55-78 |
250 |
Twin Counter |
560 |
| SE250 |
24V |
300 |
250 |
18-25/60-84 |
300 |
Twin Counter |
700 |
| SE300 |
48V |
340 |
300 |
22-30/72-100 |
300 |
Twin Counter |
400 |
E-series motors keep the rated thrust electronically over a wider voltage range, so their thrust is the same at 24/48V and 21/42V. E30–E95 are new. Battery CCA ratings are DIN; multiply by 1.9 for the SAE rating at 0° F (ABYC). CCA is the current a lead-acid battery can deliver at 0° F (−18° C) for 30 seconds while keeping at least 1.2 volts per cell (7.2 volts for a 12-volt battery).
Retractable Thrusters
E-series retract (ERL / ERV) – thrust at 24/48V and 21/42V
| Model |
Thrust high V (kg) |
Thrust low V (kg) |
Ideal vessel size (m/ft) |
Tunnel ID (mm) |
Propeller |
Voltage |
Weight (kg) |
Min. CCA (DIN) |
| ERL80/185T |
80 |
80 |
10-15/35-48 |
185 |
Twin |
12/24 |
TBD |
550/300 |
| ERL95/185T |
95 |
95 |
12-17/35-55 |
185 |
Twin |
12/24 |
TBD |
750/400 |
| ERL100/185T |
100 |
100 |
12-17/35-55 |
185 |
Twin |
24/48V |
51.7/51.5 |
300/150 |
| ERL130/250T |
130 |
130 |
13-19/42-62 |
250 |
Twin |
24/48V |
92.5/92.3 |
300/180 |
| ERL170/250TC |
170 |
170 |
15-22/50-70 |
250 |
Twin Counter |
24/48V |
93.0/92.8 |
420/255 |
| ERV100/185T |
100 |
100 |
12-17/35-55 |
185 |
Twin |
24/48V |
44.4/44.2 |
300/150 |
| ERV130/250T |
130 |
130 |
13-19/42-62 |
250 |
Twin Counter |
24/48V |
83.4/83.2 |
300/180 |
| ERV170/250TC |
170 |
170 |
15-22/50-70 |
250 |
Twin Counter |
24/48V |
83.9/83.7 |
420/220 |
| ERV210/250TC |
210 |
210 |
17-24/55-78 |
250 |
Twin Counter |
24V/48 |
90.8/90.6 |
600/320 |
| ERV250/300TC |
250 |
80 (as printed) |
22-30/72-100 |
300 |
Twin Counter |
48V |
122.3 |
350 |
| ERV300/300TC |
300 |
300 |
22-30/72-100 |
300 |
Twin Counter |
48V |
122.3 |
395 |
SR / SRL / SRV – thrust at 12/24V and 10.5/21V
| Model |
Thrust high V (kg) |
Thrust low V (kg) |
Ideal vessel size (m/ft) |
Tunnel ID (mm) |
Propeller |
Voltage |
Weight (kg) |
Min. CCA (DIN) |
| SR80/185T |
96 |
80 |
10-15/35-48 |
185 |
Twin |
12/24V |
31 |
550/300 |
| SR100/185T |
116 |
100 |
12-17/35-55 |
185 |
Twin |
12/24V |
44 |
750/400 |
| SRL80/185T |
96 |
80 |
10-15/35-48 |
185 |
Twin |
12/24V |
31 |
550/300 |
| SRL100/185T |
116 |
100 |
12-17/35-55 |
185 |
Twin |
12/24V |
44 |
750/400 |
| SRL130/250T |
160 |
130 |
13-19/42-62 |
250 |
Twin |
12/24V |
82 |
750/400 |
| SRL170/250TC |
210 |
170 |
15-22/50-70 |
250 |
Twin Counter |
24V |
88 |
560 |
| SRV80/185T |
96 |
80 |
10-15/35-48 |
185 |
Twin |
12/24V |
31 |
550/300 |
| SRV100/185T |
116 |
100 |
12-17/35-55 |
185 |
Twin |
12/24V |
44 |
750/400 |
| SRV130/250T |
160 |
130 |
13-19/42-62 |
250 |
Twin |
12/24V |
82 |
750/400 |
| SRV170/250TC |
210 |
170 |
15-22/50-70 |
250 |
Twin Counter |
24V |
88 |
560 |
| SRV210/250TC |
250 |
210 |
17-24/55-78 |
250 |
Twin Counter |
24V |
112 |
560 |
| SRV250/300TC |
300 |
250 |
11-25/59-82 (as printed) |
250 (as printed) |
Twin Counter |
24V |
141 |
700 |
| SRV300/300TC |
340 |
300 |
22-30/72-98 |
300 |
Twin Counter |
48V |
120 |
400 |
ER weights and CCA are given per voltage (24V/48V). PRO (variable speed) item codes exist for SR, SRL and SRV 80–130 models.
External Thrusters
SX – thrust at 12V (12/24V) and 10.5V (10.5/21V)
| Model |
Thrust high V (kg) |
Thrust low V (kg) |
Ideal vessel size (m/ft) |
Tunnel ID (mm) |
Propeller |
Voltage |
Weight (kg) |
Min. CCA (DIN) |
| SX35/140 50MM |
42 |
35 |
6-10/19-32 |
140 |
Single |
12V |
15.3 |
200 |
| SX35/140 150MM |
42 |
35 |
6-10/19-32 |
140 |
Single |
12V |
15.3 |
200 |
| SX50/140 50MM |
62 |
50 |
8-11/27-37 |
140 |
Single |
12V |
15.3 |
350 |
| SX50/140 150MM |
62 |
50 |
8-11/27-37 |
140 |
Single |
12V |
15.3 |
350 |
| SX35/140 50POD |
42 |
35 |
6-10/19-32 |
140 |
Single |
12V |
15.3 |
200 |
| SX50/140 50POD |
62 |
50 |
8-11/27-37 |
140 |
Single |
12V |
15.3 |
350 |
| SX 80/185 T |
96 |
80 |
10-15/35-48 |
185 |
Twin |
12/24 |
52 |
550 |
| SX 100/185 T |
116 |
100 |
12-17/35-55 |
185 |
Twin |
12/24 |
57 |
750 |
EX – thrust at 23V and performance thrust at 24V
| Model |
Thrust high V (kg) |
Thrust low V (kg) |
Ideal vessel size (m/ft) |
Tunnel ID (mm) |
Propeller |
Voltage |
Weight (kg) |
Min. CCA (DIN) |
| EX70C |
67 |
95 |
10-15/35-48 |
150 |
Single |
24V |
19.5 |
190 |
| EX95S |
67 |
95 |
10-15/35-48 |
150 |
Single |
24V |
19.5 |
190 |
| EX180D |
130 |
180 |
14-18/44-59 |
150 |
dual |
24v |
35 |
375 |
SX35/50 come for 50 mm or 150 mm hulls and as POD versions, with SXP (PRO) versions and cowls COWL-SX35/50; SX 80/100 use cowls 90080.
Control Panels and Remotes
| Item code |
Description |
Thruster signal |
|
| 8950 G |
Touchpanel (grey) |
On/Off |
View part → |
| 8955 G |
Round touchpanel (grey) |
On/Off |
View part → |
| 8960 G |
Joystick panel (grey) |
On/Off |
View part → |
| 8960 S |
Joystick panel (black) |
On/Off |
View part → |
| 8965 |
Boat switch panel |
On/Off |
View part → |
| 8940 G |
Dual joystick panel (grey) |
On/Off |
View part → |
| 8940 S |
Dual joystick panel (black) |
On/Off |
View part → |
| 8909 C |
Docking panel |
On/Off |
View part → |
| 8700 |
Touch panel retract |
S-Link CAN-bus |
View part → |
| PJC211 |
Single joystick PRO |
S-Link CAN-bus |
View part → |
| PJC212 |
Dual joystick PRO |
S-Link CAN-bus |
View part → |
| RCS-20U |
Remote bow/stern, S-Link (North America; RCS-20E for EU) |
S-Link CAN-bus |
View part → |
| RC-20U |
Remote bow/stern (RC-20E for EU) |
On/Off |
View part → |
| RC-21U |
Remote bow/windlass (RC-21E for EU) |
On/Off |
View part → |
| RC-22U |
Remote windlass x2 (RC-22E for EU) |
On/Off |
View part → |
| RC-23U |
Remote bow x2/windlass x2 (RC-23E for EU) |
On/Off |
View part → |
All panels are multi-voltage with child safety. PJC211/PJC212 and the RCS remote work with PRO DC speed control (RCS: on/off only per the sheet). Use E type remotes for EU and U type remotes for North America; the remote receiver accepts up to four independent transmitters. Most Sleipner (Side-Power) DC 12 and 24V models from 1999/2000 and later can be updated to PRO variable speed control.
Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.
Products in this Selection Guide