INSTALLATION MANUAL

Install the Sleipner S-Link automatic main switch 897712 (12V) / 897724 (24V): placement, dimensions, fuse and cable fitting, S-Link and coil-feed wiring for SEP and retract thrusters, and panel fault messages.

DocumentSleipner S-Link Automatic Main Switch 897712, 897724 Installation Manual
FormatPDF · 16 pages · 1.2 MB
LanguageEnglish
Sleipner S-Link Automatic Main Switch 897712, 897724 — Installation Manual

Considerations and Dimensions

  • Install the AMS as close to the battery bank as possible, in a location that stays dry at all times, with quick access to the shut-off button and short power cables.
  • Only connect it to compatible original Sleipner control panels or control devices.
  • Do NOT fit it in spaces requiring ignition protected equipment.
  • Use the correct fuse for the installed thruster model (see the thruster installation manual). This manual is used in addition to the thruster manual and is intended for professionals.
Code Description mm inch
H Height 194.3 7.6
L Length 205 8.1
W Width 79 3.11
+W Width including fasteners 90 3.54
(a) Attachment hole from the top 51.5 2.03
(b) Attachment hole from the bottom 92.8 3.65
(c) Attachment hole from the side 37.5 1.5
(d) Distance between attachment holes 121.8 4.8
(e) Attachment hole from the side 45.7 1.8

Mounting, Fuse and Cables

  1. Remove the cover screws and cover; secure the AMS with the two mounting holes on each side.
  2. Remove the nuts and washers, install the fuse (type and rating per the thruster installation manual).
  3. Assemble washers, battery cable(s), end washer and nuts; tighten to 20 Nm (14.5 lb/ft). The bolts are brass: excessive torque damages the threads.
  4. Fit the thruster cable(s) the same way and tighten to the recommended torque.
  5. Manual override: pulled out = remote controlled ON/OFF (default); pushed in = OFF. Leave it OFF when leaving the boat for long periods or when installing or servicing the thruster system.

Do NOT use washers between lugs: it can cause overheating and a thermal event. Spring washers go in the outer position before tightening the nut. For dual cables, leave one washer on each bolt as shown in the PDF.

Electrical Installation

  • Fit only one thruster to each automatic main switch, and install the correct main fuse for the thruster model.
  • Coil feed from any 12V or 24V battery source through a 5A fuse; an on/off switch is optional, and not needed if the source already has a main switch.
  • Connect the S-Link cable to the S-Link network; the AMS is assigned to bow or stern.
  • The system diagram shows bow and stern SEP thrusters with PPC proportional power controllers (fixed multicable 5m), PJC 212 joystick panels at two stations, optional 8730 external switch interfaces and an S-Link supply; a manual main switch with ANL fuse can replace the AMS. Observe PPC battery terminal polarity.
  • ON/OFF configuration: 4-lead cable thruster ↔ AMS (red wire not connected into the AMS); proportional: 5-lead cables and 5-lead Y-connectors to the panels. Main cable sizes per the thruster manual.

With the main switch off, check with an ohmmeter that there is no connection between the electro-motor flange and the motor positive terminal, or the battery negative terminal on the motor.

Service and Troubleshooting

  • Keep the equipment clean and dry.
  • Check all cable and other connections are tight, without signs of excessive heat or corrosion.
Panel message Action
Manual override The override button has been pushed: pull it to activate
Fuse is blown Replace the fuse, or check the main cables to battery and thruster
Communication fail Panel has lost contact with the AMS: check S-Link and/or power connections
Power failure AMS has no power: check the 5A fuse, the power connection and power on the red and black wire
Overtemperature High internal temperature from excessive current: the contactor stays open until it cools below the threshold – wait for the AMS to cool

Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.