INSTALLATION MANUAL

Deck cut-out, sealing and assembly of the Sleipner Side-Power 8750 deck footswitch (single) and 8751 kit.

DocumentSleipner Footswitch 8750, 8751 Installation Manual
FormatPDF · 2 pages · 0.1 MB
LanguageEnglish
Sleipner Footswitch 8750, 8751 — Installation Manual

Fitting Instructions

  1. The switch mounts from the top of the deck whatever the deck thickness; the part below deck must stay out of water and wet areas.
  2. Drill a 65mm (2.5") hole at the chosen position.
  3. Run a bead of sealing compound around the underside of the lower body flange without blocking its four drain holes, and centre the switch in the hole.
  4. Place the rubber cover over the plunger shaft, then the cover/bezel assembly with its six holes lined up with the flange holes.
  5. Turn the rubber cover so its arrow shows the direction of thrust for that switch.
  6. Screw cover/bezel and rubber cover down evenly with the six self-tapping screws provided.
  7. If the deck is thicker than 45mm (1.75"), make the electrical connections before securing the switch.
  8. Make all connections secure and insulated against accidental shorting. Operate the switch with firm, continuous pressure.

Sleipner footswitch 8750 exploded view: cover/bezel assembly, rubber cover, plunger shaft, lower body flange

Item code Description
8751 Footswitch kit
8750 Single switch

Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.