INSTALLATION MANUAL

Wiring for the 12-00159 signal adapter: drive an ENGBO thruster system from a Sleipner remote control receiver or a Sleipner control panel.

DocumentSleipner Signal Adapter Engbo – Sleipner 12-00159 Installation Manual
FormatPDF · 4 pages · 0.1 MB
LanguageEnglish
Sleipner Signal Adapter Engbo – Sleipner 12-00159 — Installation Manual

Sleipner 4-Way Connector

Pin Wire Signal
1 Black (-)
2 Blue Signal STB
3 Grey Signal PORT
4 Red (+)

Connection Cases

Sleipner Remote → ENGBO Panel/Thruster

  • The adapter sits between the Sleipner remote receiver's 4-way connector and the ENGBO control unit, alongside the ENGBO control panel.
  • Two layouts are shown: thrusters with relay/motor XF40R, 60R, 75R, 90R, and the XF20 thruster motor.
  • The adapter's red (B+) lead goes to BATT + on the ENGBO control unit (XF20) or to the B+ line (relay versions).
  • Remote receiver supply: see the remote control manual.
  • If the thrust direction is wrong, swap the blue and grey wires.

ENGBO Thruster → Sleipner Panel

  • A Sleipner control panel (with an optional Sleipner remote receiver) connects through the 4-lead cable to the adapter, which wires into the ENGBO control unit.
  • Relay/motor versions XF40R, 60R, 75R, 90R use a terminal block for the B+ (red) connection; on the XF20 the red lead goes to BATT +.
  • Terminal numbers and wire colours at the ENGBO control unit are shown on the diagrams in the PDF – follow them exactly.

Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.