OWNER'S MANUALGypsy and chain/rope match, deck cut-outs, cable sizing, wiring diagrams, operation, servicing, kit-level parts lists and performance data for the Lewmar VX1, VX1L, VX2, VX2+ and VX3 vertical windlasses.
DocumentLewmar VX Vertical Windlass Owner's Manual
FormatPDF · 36 pages · 11.4 MB
LanguageEnglish
Performance
| Model |
Volts |
Motor |
Typical max. pull |
Max. line speed |
Typical working load |
| VX1 |
12 |
300 W |
400 kg 882 lb
|
25 m/min 82 ft/min
|
100 kg 220 lb
|
| VX1 |
12 |
500 W |
675 kg 1488 lb
|
25 m/min 82 ft/min
|
169 kg 373 lb
|
| VX1L |
12 |
500 W |
650 kg 1433 lb
|
20 m/min 60 ft/min
|
160 kg 352 lb
|
| VX1L |
12 |
800 W |
920 kg 2028 lb
|
21 m/min 63 ft/min
|
230 kg 507 lb
|
| VX2 |
12 |
700 W |
850 kg 1874 lb
|
29 m/min 95 ft/min
|
213 kg 470 lb
|
| VX2 |
24 |
900 W |
850 kg 1874 lb
|
29 m/min 95 ft/min
|
213 kg 470 lb
|
| VX2+ |
12 / 24 |
1000 W |
1025 kg 2260 lb
|
39 m/min 128 ft/min
|
257 kg 567 lb
|
| VX3 |
12 / 24 |
1500 W |
1175 kg 2590 lb
|
40 m/min 131 ft/min
|
294 kg 648 lb
|
Values tested at +/- 10% on a 12/24V system typical of boat installations.
| Model |
Current at working load |
Weight gypsy only |
Weight gypsy/drum |
Breaker |
| VX1 300 W |
66 A |
12.5 kg (28 lb) |
13.5 kg (30 lb) |
50 A |
| VX1 500 W |
126 A |
12.5 kg (28 lb) |
13.5 kg (30 lb) |
90 A |
| VX1L 500 W |
56 A |
6.0 kg (13.5 lb) |
7.0 kg (15.4 lb) |
50 A |
| VX1L 800 W |
80 A |
6.0 kg (13.5 lb) |
7.0 kg (15.4 lb) |
70 A |
| VX2 12V |
120 A |
13.9 kg (31 lb) |
14.9 kg (33 lb) |
90 A |
| VX2 24V |
60 A |
13.9 kg (31 lb) |
14.9 kg (33 lb) |
50 A |
| VX2+ 12V |
131 A |
16.1 kg (35 lb) |
17.1 kg (38 lb) |
110 A |
| VX2+ 24V |
74 A |
16.1 kg (35 lb) |
17.1 kg (38 lb) |
90 A |
| VX3 12V |
132 A |
16.1 kg (35 lb) |
17.1 kg (38 lb) |
110 A |
| VX3 24V |
70 A |
16.1 kg (35 lb) |
17.1 kg (38 lb) |
90 A |
Gypsy & Rode Match
The gypsies are made for Lewmar rope/chain rodes (rope spliced to a chain tail). Use windlass grade, medium lay nylon rope (3 strand or 8 plait); other makes may need experimenting.
VX1 / VX1L
| Gypsy |
Rope |
Chain |
D mm |
D in |
P mm |
P in |
W mm |
W in |
| 68100034 |
12-16 mm (1/2 - 5/8") |
6 mm ISO 4565 |
6 |
0.236 |
18 |
0.709 |
21.6 |
0.85 |
| 68100034 |
|
6mm DIN766 |
6 |
0.236 |
18.5 |
0.728 |
20.4 |
0.803 |
| 68100034 |
|
7mm ISO 4565 |
7 |
0.276 |
21 |
0.826 |
23 |
0.905 |
| 68100034 |
|
7mm DIN766 |
7 |
0.276 |
22 |
0.866 |
23.8 |
0.937 |
| 68100034 |
|
1/4" G40 |
7 |
0.276 |
21.3 |
0.840 |
24.4 |
0.962 |
| 68100034 |
|
1/4" BBB |
7.14 |
0.281 |
22.1 |
0.870 |
25.2 |
0.992 |
| 68100033 |
12-16 mm (1/2") |
8mm ISO 4565 |
8 |
0.315 |
24 |
0.945 |
28.8 |
1.134 |
| 68100033 |
|
8mm DIN766 |
8 |
0.315 |
24 |
0.945 |
27.2 |
1.07 |
| 68100033 |
|
5/16" G40 |
8.4 |
0.329 |
26.2 |
1.030 |
29.7 |
1.168 |
VX2 / VX2+ / VX3
| Gypsy |
Rope |
Chain |
D mm |
D in |
P mm |
P in |
W mm |
W in |
| 68120040 |
12-16 mm (1/2 - 5/8") |
6 mm ISO 4565 |
6 |
0.236 |
18 |
0.709 |
21.6 |
0.85 |
| 68120040 |
|
6mm DIN766 |
6 |
0.236 |
18.5 |
0.728 |
20.4 |
0.803 |
| 68120040 |
|
7mm ISO 4565 |
7 |
0.276 |
21 |
0.826 |
23 |
0.905 |
| 68120040 |
|
7mm DIN766 |
7 |
0.276 |
22 |
0.866 |
23.8 |
0.937 |
| 68120040 |
|
1/4" G40 |
7 |
0.276 |
21.3 |
0.840 |
24.4 |
0.962 |
| 68120040 |
|
1/4" BBB |
7.14 |
0.281 |
22.1 |
0.870 |
25.2 |
0.992 |
| 68120041 |
12-16 mm (1/2 - 5/8") |
8 mm ISO 4565 |
8 |
0.315 |
24 |
0.945 |
28.8 |
1.134 |
| 68120041 |
|
5/16" G40 |
8.4 |
0.329 |
26.2 |
1.030 |
29.7 |
1.168 |
| 68120041 |
|
8 mm DIN 766 |
8 |
0.315 |
24 |
0.945 |
27.2 |
1.070 |
| 68120042 |
12-16 mm (1/2 - 5/8") |
Lewmar 9.5mm G40 |
9.5 |
0.374 |
28 |
1.102 |
32 |
1.260 |
| 68120042 |
|
5/16" Campbell S3 |
8 |
0.315 |
32 |
1.260 |
28 |
1.102 |
| 68120042 |
|
3/8" Campbell S4 |
10 |
0.394 |
29 |
1.142 |
35 |
1.378 |
| 68120042 |
|
10 mm DIN 766 |
10 |
0.394 |
28 |
1.102 |
36 |
1.417 |
| 68120043 |
12-16 mm (1/2 - 5/8") |
10 mm ISO 4565 |
10 |
0.394 |
30 |
1.181 |
36 |
1.417 |
| 68120043 |
|
Lewmar 9.5mm G40 |
9.5 |
0.374 |
28 |
1.102 |
32 |
1.260 |
| 68120043 |
|
3/8" Campbell S3 |
10 |
0.394 |
34.5 |
1.358 |
34.5 |
1.358 |
All gypsies take 3 strand and 8 plait rope.
Change Notice: VX2/3 6 mm Gypsy (Iss A, 05/04/2019)
- The 6 mm hybrid gypsy used on the VX2/2+/3 and RX2/2+/3 is not compatible with 6 mm ISO chain.
- For 6 mm ISO chain a new gypsy kit uses the CPX2/3 6 mm gypsy modified for the VX and RX 2/3, with revised cones; it is a direct fit.
- 68120045 (metal, 006): 6mm ISO 4564, ¼" G40, ¼" BBB; rope 12-14 mm, 1/2", 3-strand and 8-plait.
- 68120040 (hybrid, 7mm ¼"): 7mm ISO 4565, 7mm DIN766, ¼" G40, ¼" BBB; rope 12-16 mm, 1/2" – 5/8".
- 68120041 (hybrid, 8mm 5/16"): 8mm ISO 4565, 8mm DIN766, 5/16" G40; rope 12-16 mm, 1/2" – 5/8".
- 68120042 (hybrid, 10mm DIN): 10mm DIN766, 5/16" Campbell S3, 3/8" Campbell S4, 9.5mm G40; rope 12-16 mm, 1/2" – 5/8".
- 68120043 (hybrid, 10mm ISO): 10mm ISO 4565, 3/8" Campbell S3, Lewmar 9.5mm G40; rope 12-16 mm, 1/2" – 5/8".
- The 6/7mm gypsy for the VX1 and HX1 is not affected.
Planning & Deck
- Make an accurate drilling template from the product dimensions; position it relative to the bow roller, the chain locker and the handle rotation. Pick a flat area if possible.
- Lead from the roller horizontal to the top of the gypsy, on its centre line within ±5°.
- Minimum deck thickness 40mm (1 1/2"). Thin, foam or balsa cored decks need reinforcement. A deck spacer (65100038) is available for thinner decks; thicker decks need a longer shaft (not standard).
- Leave enough vertical fall for the rode; do not put the motor/gearbox under the chain pipe fall.
- Seal freshly cut hole edges. Do not use a permanent adhesive/sealant (e.g. 5200).
| Model |
Studs |
Sensor holes |
Hole saws |
| VX1 |
4 × 10 mm (3/8") |
14 mm (9/16") and 18 mm (45/64") |
40 mm (1 37/64") and 67 mm (2 1/4") |
| VX2/3 |
3 × 10 mm (3/8") |
14 mm (9/16") and 18 mm (45/64") |
46 mm (1 13/16") and 67 mm (2 1/4") |
| VX1L |
4 × 10 mm (3/8") |
15 mm (gearbox fitting) |
100 mm (3 15/16") and 67 mm (2 1/4") |
The VX2/3 tool list gives a 62 mm (2 7/16") hole saw where the fitting steps give 67 mm (as printed); check against the deck mounting detail before cutting.
Fitting
- Screw the studs into the base until they bottom out; studs with a flat go with the flat nearest the base. VX1-3 studs 21Nm.
- Place the base mat; optionally seal the base, pad or studs.
- Lightly grease the shaft, check the drive key, slide the motor/gearbox up the shaft to the deck, away from the rode fall.
- Check the mounting faces are parallel. Washer then M8 nut with Loctite threadlock, 21Nm. Let rubbery sealants cure before final tightening.
-
Loading the rode: remove the cover, pull out the control arm, feed the rode into the entry hole and tie it off, refit the cover, release the arm round the gypsy, then power load the rest.
The deck template in the manual is a guide only, not a cutter: check before drilling.
Electrical
| Model |
Current at working load |
Breaker supplied |
CSA to ISO 10133 Annex A, 20 m |
AWG to ABYC E11, 66 feet |
| VX1 300 |
66 A |
50 A |
25 mm² |
4 |
| VX1 500 |
126 A |
70 A |
35 mm² |
1 |
| VX1L 500 |
56 A |
50 A |
16 mm² |
4 |
| VX1L 800 |
80 A |
70 A |
25 mm² |
2 |
| VX2 12V |
120 A |
90 A |
35 mm² |
1 |
| VX2 24V |
60 A |
50 A |
10 mm² |
7 |
| VX2+ 12V |
131 A |
110 A |
50 mm² |
1 |
| VX2+ 24V |
74 A |
90 A |
16 mm² |
6 |
| VX3 12V |
132 A |
110 A |
50 mm² |
1 |
| VX3 24V |
70 A |
90 A |
10 mm² |
7 |
Length = battery + to battery – including breaker and switch gear. The electrical table gives a 70 A breaker for the VX1 500, the specification table 90 A (as printed). Cable insulation rated 90°C or higher; guide only, the installer confirms capacity and voltage drop.
- Fully insulated wiring, type III stranded tinned copper with copper crimp terminals; breaker close to the battery, dry and accessible. A tripped breaker must be reset by hand.
- Supplied: guarded rocker switch, contactor (VX1/VX1L 12V 68000939; VX2/3 12V 68000937, 24V 68000938). Switch wire 1.5 mm2 (16 AWG), chain counter fuse 3 A.
- Motor terminals: hold the back nut with a second wrench. VX1/2/3 front nut 15Nm to 18Nm; VX1L 5Nm to 6Nm. Do not overtighten.
- VX2/3 motor connections: D1 = F1, D2 = F2. Multi-station switches are wired in parallel.
Operation
Deploy & Recover
-
Braked free-fall: release the anchor locks, turn the handle anti-clockwise until the anchor pays out, control the rate with the handle, then fully tighten the gypsy drive cap. On gypsy/drum models use a Lewmar handle in the drum top nut.
-
Power: release locks, operate DOWN; operate UP to recover and secure the anchor to an independent strong point.
-
Manual recovery kits (VX2/3 only): gypsy 66120009, gypsy/drum 66120010.
- Always remove the winch handle after use.
Warping & Tips
-
Warping (gypsy/drum): lock the chain, put a winch handle in the top nut, turn anti-clockwise half a turn to free the clutch, remove the handle, run the drum. Re-tighten the top nut when done. Never wrap chain on the drum.
- Power the rode out while the boat takes way astern so it does not pile on the anchor; use this to moor stern-to.
- Motor towards the anchor to help recovery, but not over and beyond it.
- Scope guide as printed: depth to chain/rope 7 to 1 at anchor. Do not overload or stall; hold the rode on a cleat or chain stopper.
Servicing
Regularly
- Wash down with fresh water; check electrical connections, clean and lightly grease.
- Keep the anchor locker drain clear; if the locker floods, check the motor is dry and rust free.
- Check the rode splice and the gypsy (high wear item); smear grease on the cone/gypsy contact faces on reassembly.
- Check the mounting studs after the first two or three recoveries and regularly after.
Annually
- Check cables; strip, clean and lightly grease the above deck parts.
- Clean and repaint the motor/gearbox with marine oil based enamel if corroded.
- Remove the motor cover and blow dust off the brushes (do not breathe it).
Gypsy & Control Arm
- Isolate the windlass and secure the rode. Remove the chain cover screw (4mm allen key on VX1/VX1L, 5mm on VX2/3), pull the control arm out and lift off the cover and arm.
- Gypsy only: remove top cap, washer and upper cone. Gypsy/drum: undo the drum top cap, remove drum, drum washer, upper cone washer and upper cone. Lift off the gypsy.
- VX1/VX1L: to replace the lower cone and washer, remove the cone circlip. Fit the new gypsy with the part number on the stripper ring facing up.
- VX1/VX1L control arm is captive in the cover (release the t-clip on the hinge pin); VX2/3 arm comes off with its shoulder screw (5 mm Allen) and torsion spring. Wash in clean water (not jetwash) and grease the spring on reassembly.
Troubleshooting
-
Rode pays out on its own: rode not secured and gypsy drive cap slack. Tighten the cap with the winch handle and always secure the rode independently.
-
Will not run or sluggish: usually electrical. Keep 13.5 Volts on 12 V systems (26.5 Volts on 24 V); check cable size, switches, connections, battery, isolator, fuse and motor.
Parts Lists (Kits)
The extra download lists the complete VX 2/3 and RX 2/3 windlass part numbers (12v/24v, 6 mm and 7 mm, gypsy only and gypsy/drum).
Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.
Products in this Manual