INSTALLATION MANUALSizing, package contents, sailmaker's dimensions, top foil worksheet, assembly, wiring and wire sizes, operation, manual override, service intervals, troubleshooting and spare parts for the MKIV Electric Unit 2E and 3E jib furlers.
DocumentHarken MKIV Electric Jib Reefing & Furling Unit 2E, 3E Installation Manual
FormatPDF · 48 pages · 6.3 MB
LanguageEnglish
Sizing Check
| Part no. |
Unit |
Wire Ø |
Rod Ø |
|
| 7412.13 12V |
MKIV Electric Unit 2E, 12 V |
5/16", 3/8" (8, 10 mm) |
-12, -17, -22 (7.14, 8.38, 9.53 mm) |
Ask us to source it → |
| 7412.13 24V |
MKIV Electric Unit 2E, 24 V |
5/16", 3/8" (8, 10 mm) |
-12, -17, -22 (7.14, 8.38, 9.53 mm) |
Ask us to source it → |
| 7413.13 12V |
MKIV Electric Unit 3E, 12 V |
7/16", 1/2" (11, 12 mm) |
-22, -30 (9.53, 11.10 mm) |
Ask us to source it → |
| 7413.13 24V |
MKIV Electric Unit 3E, 24 V |
7/16", 1/2" (11, 12 mm) |
-22, -30 (9.53, 11.10 mm) |
Ask us to source it → |
Toggles and rod adapter studs (sold separately)
| Part no. |
Description |
Clevis pin |
Unit |
|
| 7312.22 5/8 |
Jaw/jaw toggle with short link plate |
5/8" (15.9 mm) |
2E |
Ask us to source it → |
| 7413.22 3/4 |
Jaw/jaw toggle with short link plate |
3/4" (19.1 mm) |
2E, 3E |
Ask us to source it → |
| 7413.22 7/8 |
Jaw/jaw toggle with short link plate |
7/8" (22.2 mm) |
3E |
Ask us to source it → |
| 7424 -12 |
Rod adapter stud with nosepiece |
— |
2E |
View part → |
| 7425 -17 |
Rod adapter stud with nosepiece |
— |
2E |
View part → |
| 7426 -22 |
Rod adapter stud with nosepiece |
— |
2E, 3E |
View part → |
| 7427 -30 |
Rod adapter stud with nosepiece |
— |
3E |
View part → |
A Harken toggle/link plate assembly is required, and the mating turnbuckle with an eye at the lower end is bought separately. Bushings may be needed for smaller clevis pins. Black anodized foils standard since April 2021; clear foils available.
Do not drill the boat's chainplate or toggle: it can cause rig failure. Use the correct toggle and clevis pin, and have an old headstay checked by a professional rigger.
Standard Package
| Part no. |
Description |
Unit |
|
| 7412.31.BLACK |
7' (2.13 m) foil, standard (8 per unit) |
2E |
Ask us to source it → |
| 7413.31.BLACK |
7' (2.13 m) foil, standard (10 per unit) |
3E |
Ask us to source it → |
| 7412.33.BLACK |
2' (610 mm) bottom foil |
2E |
Ask us to source it → |
| 7413.33.BLACK |
2' (610 mm) bottom foil |
3E |
Ask us to source it → |
| 7412.31F |
Connectors 9.75" (248 mm), 7 per unit |
2E |
Ask us to source it → |
| 7413.31F |
Connectors 9.75" (248 mm), 9 per unit |
3E |
Ask us to source it → |
| 7412.32F |
Bottom connector 14" (356 mm) |
2E |
Ask us to source it → |
| 7413.32F |
Bottom connector 14" (356 mm) |
3E |
Ask us to source it → |
| H-39794 |
Halyard swivel |
2E |
Ask us to source it → |
| H-39392 |
Halyard swivel |
3E |
View part → |
| BEB500.12.1 |
Electric control box, 12 V |
2E, 3E |
View part → |
| HCP1918 |
40 A circuit breaker, 12 V |
2E, 3E |
Ask us to source it → |
| BEB500.24.1 |
Electric control box, 24 V |
2E, 3E |
Ask us to source it → |
| HCP1917 |
30 A circuit breaker, 24 V |
2E, 3E |
Ask us to source it → |
| DSDBK2 |
Digital system switch |
2E, 3E |
Ask us to source it → |
| 7430 |
Emergency crank handle |
2E, 3E |
View part → |
| 7431 |
Drill adapter for manual drive |
2E, 3E |
View part → |
| 947 |
Prefeeder |
2E, 3E |
View part → |
| HFG725 |
Injector with 1 oz 5200 adhesive |
2E, 3E |
Ask us to source it → |
| 2117 |
Bow shackle (8 mm) |
2E |
View part → |
| 2124 |
Bow shackle (10 mm) |
3E |
View part → |
Also supplied: Parker 801 hose 1/2" ID, 2' (610 mm) with hose clamp, connector bushings, wedges, foil screws, trim cap and screws, feeder, blue and red Loctite, hex keys (3, 4, 5, 6 mm for 2E; 3, 4, 6, 10 mm for 3E).
Sailmaker's Dimensions
| Lower unit + toggle |
A |
B |
C |
D |
E |
F |
G |
H |
| 7412.13 + 7312.22 5/8 |
5 3/8" (143) |
9 1/8" (231) |
3 1/4" (82) |
33 1/16" (841) |
24 1/2" (622) |
22 5/8" (574) |
4 1/2" (116) |
8 11/32" (212) |
| 7412.13 + 7413.22 3/4 |
5 3/8" (143) |
9 1/8" (231) |
3 1/4" (82) |
(856) |
25 3/32" (637) |
23 1/4" (590) |
5 3/16" (132) |
8 11/32" (212) |
| 7413.13 + 7413.22 3/4 |
7 5/16" (186) |
11 5/8" (296) |
3 1/4" (82) |
32 1/2" (826) |
25 3/32" (637) |
23 1/4" (590) |
5 3/16" (132) |
8 11/32" (212) |
| 7413.13 + 7413.22 7/8 |
7 5/16" (186) |
11 5/8" (296) |
3 1/4" (82) |
33 3/16" (840) |
25 11/16" (652) |
23 13/16" (605) |
5 3/4" (146) |
8 11/32" (212) |
Millimetres in brackets. Letters follow the drawing on page 7 of the PDF: A and B on the halyard swivel, C the tack setback, D from the clevis pin to the top of the lower unit, E to H on the lower unit and toggle.
Luff
- Luff tape #6 (6/32" or 5 mm); cut the top of the tape 18–24" (450–600 mm) below the head and extend it below the feeder.
- Minimum inside shackle dimensions: 2E A 1 3/4" (44 mm), B 11/16" (17 mm); 3E A 1 7/8" (48 mm), B 13/16" (21 mm).
- A shorter luff may be needed with a halyard restrainer or an extra toggle. Sun cover on either side; match the rest of the inventory.
Foil Height
- Top foil with cap rides below the upper terminal: 2E 5/8" (16 mm), 3E 1" (25 mm); just below the shoulder of a swage.
- With a 7303 or 7304 halyard deflector, add 25 mm (1").
- Pin-to-pin length of the toggle for snaking the stay: 5/8" (15.9 mm) pin 2 5/8" (67 mm), 3/4" (19.1 mm) pin 3 9/32" (83 mm), 7/8" (22.2 mm) pin 3 7/8" (98 mm).
Top Foil Worksheet
| Dimension |
Unit 2E |
Unit 3E |
| B: bottom of terminal to top of foil |
.63" (16 mm) |
1.00" (25 mm) |
| D: number of foils × |
84" (2133.6 mm) |
84" (2133.6 mm) |
| E: bottom foil |
24.0" (610 mm) |
24.00" (610 mm) |
| F: bottom of foil to top of link plates |
17.5" (445 mm) |
15.41" (391 mm) |
| G with 7312.22 5/8 toggle |
11.67" (296 mm) |
— |
| G with 7413.22 3/4 toggle |
12.27" (312 mm) |
12.27" (312 mm) |
| G with 7/8" toggle |
— |
12.85" (327 mm) |
| Short top foil threshold |
8 11/16" (221 mm) |
9 3/4" (248 mm) |
Top foil length C = pin-to-pin − (A + B + E + F + G) − D. Below the short-top-foil threshold, the PDF gives cutting techniques (shorten the adjoining foil, connector and trim cap); under 1" (25 mm) on the 2E or 1 1/2" (38 mm) on the 3E, eliminate the top foil.
Assembly
Foils go together with the supplied 3M 5200 adhesive, injected dry. Cure is best at 70°F (22°C) and 50% humidity; do not apply below 40°F (5°C) or above 100°F (38°C). Use opened adhesive within 3 hours. Foils can be raised and the sail fitted right after assembly; if possible let it sit a couple of days before sailing. 4200 Fast Cure is the faster alternative. Damaged foils can be separated by heating the joint with a propane torch.
Foils
- Drill two 5/32" (4 mm) trim cap holes; centre punch marks 3/8" (10 mm) and 1 3/16" (30 mm) from the top on the 2E, 3/8" (10 mm) and 1 3/8" (35 mm) on the 3E.
- Plastic bushing halves on the stay with the hook of the longer half facing out; tap the trim cap in and fit its screws.
- Red Loctite in the screw holes; inject 3/4–1 ml of adhesive per joint on the 2E, 1–1 1/4 ml on the 3E, stopping when it shows at a screw hole.
- Halyard swivel above the feeder window, taller half up. Slide the lower unit on with the clamp facing down to clear the foil notches.
Toggle, Feeder and Rig
- Rod: red Loctite on the nosepiece threads, align the flats with the two cotter pin holes, fit and spread both cotter pins.
- Sta-Lok or Norseman stud: fit the washer above the stud. Shallow jaw of the toggle up.
- Isolator and link plates to the lower unit with blue Loctite; secure to the toggle with locknuts. A ball-end hex key helps.
- Feeder screw is plastic-coated and stiff; when removing, loosen no more than one full turn.
- Turnbuckle on the boat: hold the lower unit about 5' (1.5 m) up on one halyard and the foils on a second; renew cotter pins and locknuts.
Make sure the drum assembly and foils are securely lifted on a halyard before adjusting the turnbuckle. The foils can drop suddenly and injure hands.
Electrical System
| Cable run |
0–5 m (0–16.4 ft) |
5–10 m (32.8 ft) |
10–15 m (49.2 ft) |
15–20 m (65.6 ft) |
| Wire size, 12 or 24 V |
10 mm² / 6 AWG |
16 mm² / 4 AWG |
25 mm² / 2 AWG |
35 mm² / 1 AWG |
- Remote switch wire 14 AWG (2 mm²) with a 5 A fuse; ring terminals on all connections.
- Remote circuit breaker between the power supply and the control box: 40 A (HCP1918) on 12 V, 30 A (HCP1917) on 24 V.
- Run the power wire inside the supplied 1/2" ID Parker hydraulic hose (19.7 mm / .775" OD), clamped to the coupling extension, so the motor compartment stays watertight.
- 7406 through-deck fitting: 1 3/8" (35 mm) hole saw, 1/4" (6.25 mm) drill, three 6 mm × 35 mm fasteners, sealant and blue Loctite. Drilling template on page 45 of the PDF.
- Unit 3E performance charts (12.7 V and 25.4 V) give typical boat length 45'–60'.
Mount the control box with the terminals up or sideways, never upside down: the system will not operate.
Operation
Halyard and Furling
- Halyard swivel within the top 4–6" (100–152 mm) of the foil, halyard pulling 8–10° aft. Fit a permanent plastic-coated wire pendant if the luff is short.
- Halyard deflector 7303 (Unit 2) or 7304 (Unit 3), or halyard restrainer 945, when the sheaves sit too close to the headstay.
- Sun cover on the port side: furl clockwise; on starboard: counter-clockwise. Label the switches furl / unfurl.
- Ease sheets and furl in small steps in a breeze. Stop at once if a sheet jams, the halyard wraps or the motor labours.
Manual Operation
- Check the emergency handle can rotate without hitting the pulpit.
- Disconnect power and tell the crew not to restore it; go forward with PFD, harness and tether.
- Unthread the manual drive cap and turn the foil with the 7430 emergency handle or a cordless drill on the 7431 adapter.
- Always carry the emergency handle; a cordless drill can run flat.
After a halyard wrap, do not go aloft on the boat's halyards and do not use the boat: have a professional rigger inspect the masthead from a separate hoist and replace damaged parts.
Maintenance
Clean and Store
- Flush the unit with soap and fresh water whenever you wash the boat; occasionally lower the sail and flush the halyard swivel.
- Scrub inside the grooves with a scrap of luff tape. Spray McLube on the sail luff tape off the boat: sprayed decks are very slippery.
- Loosen the foil clamp and lower the foil before slacking the backstay, or the foils can lock against the upper terminal.
- Where it freezes, store the foils under cover, grooves down or at an angle. Ice will rupture the aluminium.
- Remove the lower unit and halyard swivel for storage or transport; clean them thoroughly afterwards, including the tack and swivel ball bearings.
Inspect
- Chafe, wear or damage; clevis and cotter pins below and inside the lower unit; headstay tension.
- Swage fitting and lower toggle for stress corrosion; Norseman, Sta-Lok or rod terminals for loosening.
- All screws on the unit; that the foil has not dropped into the lower unit; the wire for wear or unravelling.
| Lower unit service |
Interval |
| Normal use |
Every four years |
| Harsh conditions such as high heat or charter use |
Every two years |
The rebuild replaces seals and grease. Get an RMA number from Harken and send the lower unit with motor housing, motor, emergency drive cap and tack shackle. Disassembly without training can let moisture in.
Troubleshooting
| Problem |
Probable cause |
Solution |
| Sail will not furl or is hard to furl |
Halyard wrapping: swivel too low or halyard angle too shallow |
Raise the swivel with a wire pendant, or fit a halyard restrainer |
| Sail will not furl or is hard to furl |
Foils riding on the turnbuckle, or too high and binding on the swage eye |
Raise or lower the foils (adjusting turnbuckle) |
| Sail will not furl or is hard to furl |
Salt or dirt in bearings |
Flush with fresh water and lubricate with a dry spray lubricant such as McLube |
| Sail will not furl or is hard to furl |
Sail flogging too much |
Release a short length of sheet, furl a small amount and repeat |
| Sail will not furl or is hard to furl |
Foil out of clamp |
Reinstall the foil in the lower unit and tighten the clamp screws |
| Headstay rotates in jerks or elliptically |
Insufficient headstay tension |
Tighten headstay and/or backstay |
| Sail does not stay furled |
Sail not furled tightly |
Keep some sheet tension when furling in light air |
| Sail will not go up |
Luff tape frayed or wrong size, dirt in groove |
Check the tape; clean the groove with a scrap of luff tape on a halyard and downhaul |
| Sail will not raise completely or luff will not tension |
Halyard swivel hitting the end stop |
Luff is too long and must be recut |
| Sun cover rolls up inside the sail |
Wrong switch used to furl |
Unroll and furl with the other switch; label the switches furl / unfurl |
MKIV Electric 2E / 3E Spare Parts
| Part no. |
Description |
Unit |
|
| 7412.13BASE 12V |
Lower unit 12 V |
2E |
Ask us to source it → |
| 7412.13BASE 24V |
Lower unit 24 V |
2E |
Ask us to source it → |
| 7413.13BASE 12V |
Lower unit 12 V |
3E |
Ask us to source it → |
| 7413.13BASE 24V |
Lower unit 24 V |
3E |
Ask us to source it → |
| H-42346 |
Torque tube clamp |
2E |
Ask us to source it → |
| HFS747 |
Torque tube screws (4) |
2E |
View part → |
| H-42967 |
Torque tube clamp |
3E |
Ask us to source it → |
| HFS1107 |
Torque tube screws (4) |
3E |
View part → |
| H-40516 |
Manual drive cap |
2E, 3E |
Ask us to source it → |
| 4665 |
Cap safety label |
2E, 3E |
Ask us to source it → |
| H-73616 |
Motor housing kit 12 V (also replaces earlier housing styles) |
2E, 3E |
Ask us to source it → |
| H-73805 |
Motor housing kit 24 V (also replaces earlier housing styles) |
2E, 3E |
Ask us to source it → |
| MP-127 |
Torlon ball bearings for H-39794 swivel (92) |
2E |
Ask us to source it → |
| H-38028A |
Clip/Smalley ring (2) |
2E |
Ask us to source it → |
| MP-128 |
Torlon ball bearings for H-39392 swivel (88) |
3E |
Ask us to source it → |
| H-39916 |
Clip/Smalley ring for balls (2) |
3E |
Ask us to source it → |
| HFG681 |
Trim cap set without screws |
2E |
View part → |
| HFG682 |
Trim cap set without screws |
3E |
View part → |
| HFG672 |
Trim cap screw set (HFS1127) |
2E, 3E |
View part → |
| HFG348 |
Foil screw set (38 HFS1106) |
2E |
View part → |
| HFG349 |
Foil screw set (46 HFS1106) |
3E |
View part → |
| HFG296 |
Connector bushing set (H-42032 / H-42033) |
2E |
View part → |
| HFG297 |
Connector bushing set (H-42073 / H-42074) |
3E |
View part → |
| HFG300 |
Plastic connector wedge set (18 H-39487) |
2E |
View part → |
| HFG324 |
Plastic connector wedge set (22 H-39487) |
3E |
View part → |
| HFG626 |
Connector set without bushings |
2E |
View part → |
| HFG627 |
Connector set without bushings |
3E |
View part → |
| H-39559 |
Feeder with screw (HFS1129) and tab (H-35671A) |
2E |
View part → |
| H-39756 |
Feeder with screw (HFS1130) and tab (H-38372A) |
3E |
View part → |
| H-44998 |
Isolator |
2E, 3E |
Ask us to source it → |
| HFS748 |
Link plate screw M6 × 1 × 20 socket cap (10 per toggle) |
2E, 3E |
Ask us to source it → |
| HFS937 |
M12 nylon locking nut (5/8" toggle) |
2E |
View part → |
| HFS991 |
M16 nylon locking nut (3/4", 7/8" toggles) |
2E, 3E |
View part → |
| HFS203 |
Cotter pin 5/32" × 1 1/4" 18-8 |
2E, 3E |
View part → |
| 945 |
Halyard restrainer (optional) |
2E, 3E |
View part → |
Toggle legs, crosspins and clevis pins differ by pin size: see the toggle parts list in the PDF.
Parts in this Manual We Carry
Harken part numbers as printed in the installation manual, matched to the genuine parts in our store.
Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.
Products in this Manual