Instructions for use and maintenance of the Lalizas ESCAPE-15 Emergency Escape Breathing Device (EEBD, MED approved): checks, donning, rated duration, function test, charging, service intervals and spare part codes.

Application / Limitation
- To be used only for ESCAPE from a compartment that has a hazardous atmosphere.
- Not to be used for fighting fires, entering oxygen deficient voids, tanks, diving, or to be worn for a complete shift.
- Approved to MED Directive by DVL GL (as printed); conforms to 2014/90/EU MED directive.
Short Description
- Air cylinder, regulator reducer, pressure gauge, pressure hose, carrying bag, hood-orinasal mask.
- Opening the lid of the bag releases a locking clip and activates the valve pressure reducer: constant breathing air flow through the hose into the hood.
- Air supply lasts 15 minutes from opening the lid of the bag (not from putting on the hood). End of rated duration is at 10bar cylinder pressure, visible in the gauge window on the bag.
- Shelf life 10 years from cylinder manufacturing date.
Before Use
- Supplied ready for immediate use.
- Check the pressure gauge: needle at about 200 bar. Cylinders are filled at about 20°C to 200 bars; stored at 0°C the needle shows about 185bars, at 40°C about 215bars. The quantity of air (and duration) is the same in all cases.
- Check the anti-tamper tag on the lid of the bag is intact.
Use & Fitting
- Place the neck strap of the carrying bag overhead and adjust until the equipment sits in the centre of the chest.
- Pull upwards the 'pull strap' on the lid of the bag: air supply into the hood begins; you have 15 minutes of steady air supply.
- Immediately remove the hood, grip both sides of its base with the hands inside the neck seal, stretch the neck seal and put the hood over the head with the half mask over nose and mouth. Breathe normally and leave the hazardous environment as soon as possible.
- Spectacle wearers: stretch the neck seal over spectacles.
- Do not remove the equipment until in a safe area. At the end of rated duration remove the hood and take off the equipment.
- After use: do not drop or throw down the equipment; pass it to an authorized service station.
Warning (Lalizas): duration begins from activation of the air supply, not from putting on the hood. Time required to escape to a safe area must be within the specified capacity of the equipment. Although exposed parts are chosen not to give rise to frictional sparks, the apparatus should not be used in explosive atmospheres.
Maintenance & Service Intervals
| Action | After use | Every month | Every 4 months | Every 1 year | Every 2 years | Every 5 years |
|---|---|---|---|---|---|---|
| Clean and disinfect as necessary (A) | X | |||||
| Visual inspection (B) | X | X | ||||
| Charge cylinder to correct pressure (C) | X | |||||
| Function test (E) | X | |||||
| Check manufacturing date on the cylinder | X | X | ||||
| Check gauge needle | X | X | X | |||
| Annual service (authorized service station) | X | |||||
| Air replacement (authorized service station) | X | |||||
| Hydraulic test (D) (authorized service station) | X |
- Cleaning (A): no organic solvents (acetone, alcohol, white spirit, trichloroethylene or similar); do not immerse the hood assembly or valve; clean with a cloth moistened in cleaning/disinfecting solution, remove residue with a cloth moistened with clean water, then dry. Cleaning and disinfecting not above 30°C; drying not above 60°C. No mechanical, electrical or ultrasonic agitation.
- Visual inspection (B): hood and neck seal; valve/reducer, hose and connections; bag, straps and buckles.
- Charging (C): air quality to EN12021; cylinder conforms to national standards, carries original test date and test mark, and the next hydraulic test date (D, every five years after manufacture) is not exceeded. Press the plunger on top of the reducing valve with a plastic probe and insert the locking clip; remove the G5/8 plug and connect the G5/8 hand wheel of the charging hose; set the compressor to 200bar; at ambient the gauge should read about 200 bar ('Boost' charge if required); vent the hose, remove it and refit the plug. Charging can raise temperature and give an incomplete charge.
- In the end: repack the unit into the bag; connect the clip to the D ring for the 'ready for use' condition without detaching the locking clip from the valve; close the lid.
- Daily check: cylinder fully charged (about 200 bar), anti-tamper tag intact, unit available.
- Function test (E): lasts only a few seconds. Remove the cylinder from the bag, pull the locking pin, listen for the air and feel the airflow inside the hood; stop it by pressing the plunger on top of the reducing valve with a plastic probe; insert the locking pin and put the cylinder back. If in doubt, contact a service station.
- Storage: protect from the environment; in wall cabinets keep the contents gauge visible for the daily check. Transport tightly packed in a strong box.
Lalizas: training and reading the instructions are necessary before use; only trained competent personnel should inspect and service, keeping a record; service only by Lalizas authorized service stations; notify Lalizas of any fault or failure. Comply also with national regulations of the country of use, including for equipment in storage.
Spare Parts
| Code | Description | |
|---|---|---|
| 01611 | Anti-tamper tags | Ask us to source it → |
| 01614 | Hood and Pipe for EEBD | Ask us to source it → |
| 01616 | Bag for EEBD | Ask us to source it → |
| 01623 | Wall Bracket for EEBD | Ask us to source it → |
Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.
Products in this Manual
-

Lalizas Emergency Evacuation Breathing Device ''Escape-15'', Solas/Med-Mer
LAL-70321
$295.00 USDUnit price /