Product information and rearming instructions for the Hammar MA1 hydrostatic inflator fitted to Lalizas inflatable lifejackets: how it activates, the single point indicator, the 5-year expiry, rearming steps and final checks.
DocumentLalizas Lifejackets with Hammar MA1 Inflator Instructions & Rearming
FormatPDF · 15 pages · 1.7 MB
LanguageEnglish
Download PDF ▾

The MA1 Inflator
- Automatic inflator with manual backup: it punctures the gas cylinder to give the lifejacket full buoyancy.
- Activates automatically when submerged and a pressure difference of about 10 cm is reached; full buoyancy within seconds.
- Hydrostatic valve: protection against inadvertent inflation from rain, spray, splash or humidity.
- Out of water performance: temperature +65°C to –30°C; high humidity, rain and wave resistance.
- Don the lifejacket according to the lifejacket manufacturer's instructions to secure its function and automatic inflation.
Single Point Indicator & Service
- Green: inflator ready for use. After activation (automatic or manual) it turns red and the inflator must be replaced. Always check the indicator before using the lifejacket.
- The inflator needs no service or maintenance for 5 years: replace it after the five years expiry date or when the indicator is red.
- All inflatable lifejackets need an annual service: follow the lifejacket manufacturer's instructions.
In Water Performance
- >10 cm pressure difference = activation depth reached: automatic activation.
- <10 cm pressure difference = activation depth not reached: manual activation required.
- If you wear a survival suit or other clothing that increases your buoyancy, you might want to activate before the 10 cm pressure difference is reached: pull the pull-tab. Make sure you know how to reach the pull-tab on your lifejacket.
Rearming After Use or When Expired
| Ref. | Rearming kit part |
|---|---|
| A | Gas cylinder + body |
| B | Sealing ring |
| C | Cap with hydrostatic valve |
| D | Locking ring |
| E | Opening key |
- Work on a smooth, flat and dry surface. Insert the opening key between the black locking ring and the yellow cap and turn it anticlockwise; the locking ring turns anticlockwise.
- Hold the yellow cap with one hand and keep turning the locking ring anticlockwise until it stops.
- Lift off the yellow cap. Remove the old inflator body and gas cylinder from inside the bladder and dispose of them in an environmentally friendly manner.
- Check the rearming kit: single point indicator on the cap green; indicator on the black body green; expiry date on the cap within limit; correct gas cylinder size. Do not assemble any cap or body that does not meet these requirements.
- Insert the inflator body in the bladder with the gas cylinder pointing upwards; let the sealing ring rest on the rounded sealing surface of the body.
- Position the replacement cap with the hydrostatic valve pointing to the right, 90° relative to the gas cylinder, and put it on the body.
- Press firmly on the cap and turn the black locking ring clockwise into the locked position.
Final Check
- Pull the cap to make sure it is locked on the inflator body.
- Check the locking ring is locked and cannot be turned anticlockwise by hand.
- Inflate the lifejacket through the oral tube and check it stays inflated at least over night.
Packing
- Deflate through the oral tube and press all residual air out of the bladder so it can be folded per the lifejacket manufacturer's instructions.
- Make sure the lifejacket is dry before packing.
Rearming kit: ask your dealer for the kit suitable for your lifejacket.
Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.