INSTRUCTIONS

Product information and rearming instructions for the Hammar MA1 hydrostatic inflator fitted to Lalizas inflatable lifejackets: how it activates, the single point indicator, the 5-year expiry, rearming steps and final checks.

DocumentLalizas Lifejackets with Hammar MA1 Inflator Instructions & Rearming
FormatPDF · 15 pages · 1.7 MB
LanguageEnglish
Lalizas Lifejackets with Hammar MA1 Inflator — Instructions & Rearming

The MA1 Inflator

  • Automatic inflator with manual backup: it punctures the gas cylinder to give the lifejacket full buoyancy.
  • Activates automatically when submerged and a pressure difference of about 10 cm is reached; full buoyancy within seconds.
  • Hydrostatic valve: protection against inadvertent inflation from rain, spray, splash or humidity.
  • Out of water performance: temperature +65°C to –30°C; high humidity, rain and wave resistance.
  • Don the lifejacket according to the lifejacket manufacturer's instructions to secure its function and automatic inflation.

Single Point Indicator & Service

  • Green: inflator ready for use. After activation (automatic or manual) it turns red and the inflator must be replaced. Always check the indicator before using the lifejacket.
  • The inflator needs no service or maintenance for 5 years: replace it after the five years expiry date or when the indicator is red.
  • All inflatable lifejackets need an annual service: follow the lifejacket manufacturer's instructions.

In Water Performance

  • >10 cm pressure difference = activation depth reached: automatic activation.
  • <10 cm pressure difference = activation depth not reached: manual activation required.
  • If you wear a survival suit or other clothing that increases your buoyancy, you might want to activate before the 10 cm pressure difference is reached: pull the pull-tab. Make sure you know how to reach the pull-tab on your lifejacket.

Rearming After Use or When Expired

Ref. Rearming kit part
A Gas cylinder + body
B Sealing ring
C Cap with hydrostatic valve
D Locking ring
E Opening key
  1. Work on a smooth, flat and dry surface. Insert the opening key between the black locking ring and the yellow cap and turn it anticlockwise; the locking ring turns anticlockwise.
  2. Hold the yellow cap with one hand and keep turning the locking ring anticlockwise until it stops.
  3. Lift off the yellow cap. Remove the old inflator body and gas cylinder from inside the bladder and dispose of them in an environmentally friendly manner.
  4. Check the rearming kit: single point indicator on the cap green; indicator on the black body green; expiry date on the cap within limit; correct gas cylinder size. Do not assemble any cap or body that does not meet these requirements.
  5. Insert the inflator body in the bladder with the gas cylinder pointing upwards; let the sealing ring rest on the rounded sealing surface of the body.
  6. Position the replacement cap with the hydrostatic valve pointing to the right, 90° relative to the gas cylinder, and put it on the body.
  7. Press firmly on the cap and turn the black locking ring clockwise into the locked position.

Final Check

  • Pull the cap to make sure it is locked on the inflator body.
  • Check the locking ring is locked and cannot be turned anticlockwise by hand.
  • Inflate the lifejacket through the oral tube and check it stays inflated at least over night.

Packing

  • Deflate through the oral tube and press all residual air out of the bladder so it can be folded per the lifejacket manufacturer's instructions.
  • Make sure the lifejacket is dry before packing.

Rearming kit: ask your dealer for the kit suitable for your lifejacket.

Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.