INSTRUCTIONS
Inspection intervals, zipper care, repacking, cleaning and donning steps for the Lalizas Neptune SOLAS immersion suit, plus the procedure for the Lalizas inspection device used for the air-pressure test and repair of immersion suits.
DocumentLalizas Neptune Immersion Suit SOLAS Instructions for Use
FormatPDF · 1 page · 0.1 MB
LanguageEnglish

Inspection & Care Intervals
| Interval | What Lalizas states |
|---|---|
| Monthly | Inspections suggested to be carried out by the ship's crew according to SOLAS regulation III/20.7. Monthly donning practice should reduce donning time from minutes to seconds. |
| Every six months | Hang the suit on a broad hanger for at least 48 hours so any moisture inside can dry out. |
| At least once a year | Lubricate the zippers (or whenever the chain feels dry and the sliding force is up); for a frequently used suit, approx. every 10 uses. |
| Not exceeding three years | Full inspection by a Lalizas authorized service station (more frequently for suits over ten years of age). Contact your Flag Administration for further advice. |
Zipper Operation & Service
- Before opening and closing, remove dust and debris from the zipper teeth, inside and outside, with water or a brush.
- Pull the zipper head in the same direction as the zipper teeth: wrong pulling can damage the teeth and the zipper's airtight performance.
- Pull slowly; do not open and close repeatedly for a long time (the head gets hot and damaged).
- If cloth blocks the zipper, pull the head back slightly, free the cloth and try again. Never force it.
- Apply the candle (stick up and down) on the outside of the closed zipper, open and close it TWICE, then store the suit with the zipper OPEN.
Repacking & Cleaning
- Lay out on a flat clean surface, arms out, zipper OPEN. Roll from the feet up to the chin.
- Heavy bending may cause leakage: permanent bends should not be sharper than 2.5 cm radius.
- Tuck the face flap into the neck area (so the Velcro does not attach to the suit), fold the arms over the rolled legs and across the chest, tuck the hood into the roll, place in the bag and pull the safety ropes slowly.
- Store in a clean, dry area accessible immediately in an emergency; do not compress the suit (loss of thermal protection).
- If soiled or contaminated with oil, hand-wash with mild detergent, rinse with plenty of fresh water, rub stains gently with a soft bristle brush and dry before packing. NEVER dry-clean or expose it to chemical solvents or cleaners.
Donning Instructions for Lalizas Immersion Suits
- Remove the suit from the storage bag.
- Don the suit, feet first, while lying or sitting on the deck.
- Place your weaker arm first into the sleeve of the immersion suit.
- Put on the hood with your free hand & put your free arm into the sleeve.
- Pull the zipper straight up to close.
- Secure the flap over the face / mouth. To avoid injury make sure that all straps are secured.
- Don the lifejacket. If your lifejacket is inflatable, do not activate it until immersed in water.
- Jump into the water, feet first.
- Turn onto your back.
Lalizas: do not fully don the immersion suit inside a vessel's cabin, as the buoyancy of the suit makes it difficult to escape from an enclosed space.
Inspection Device for Immersion Suits (70168)
The aluminum kit contains: A face fixture (two parts), B pressure gauge (0–6kPa), C foot pump (with multi-valve adaptor), D glue and applicator.
Set-up & Air Test
- Lay the suit on a work table and check for damage.
- Place face fixture part 1 inside the hood area and zip up, stretching the hood fabric so it has no folds; fit face fixture part 2 through the bolts and joints (the zipper head passes through the hole).
- Install the o-ring gasket and tighten the butterfly nut to eliminate leakage around the face seal.
- Check the pressure gauge (dial surface & pointer), insert it in the face fixture socket, fit the foot pump connector and the multi-valve adaptor.
- Pump air into the suit to 0,7 up to 1,4 kPa (0.1 to 0,2 psi) [acc. MSC/Circ.1114] and maintain it for the test (some bubbles at the zipper slides and toothed part in the face fixture are normal).
- Sprinkle seams and closures with soapy water, check for bubbles and mark the leaking areas.
Repair & Service Date
- Remove the test device, clean the suit with fresh water and dry it, keeping the marks visible.
- Seams and closures: apply a gentle amount of glue on the marked areas, let dry 8–10 minutes, apply a second layer, let dry 8 hours.
- Rips, tears and punctures: glue both sides, let dry 8–10 minutes, glue both sides again, press together for 2 minutes, let dry 8 hours.
- Mark the service date (air pressure test) on the suit's service table, or on the indicated area with the date and type of service.
Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.