INSTRUCTIONS

Instructions of use for the Lalizas Self-Contained Breathing Apparatus SOLAS/MED 71327 (6L) and 71328 (9L): components, technical data, pre-use checks, donning and doffing, cylinder change, service intervals, charging and storage.

DocumentLalizas Self-Contained Breathing Apparatus SOLAS/MED Instructions of Use
FormatPDF · 12 pages · 0.4 MB
LanguageEnglish
Lalizas Self-Contained Breathing Apparatus SOLAS/MED — Instructions of Use

Technical Data

Item 71327 71328
Type Open circuit, positive pressure Open circuit, positive pressure
Air supply On demand On demand
Warning pressure 50-60Bar 50-60Bar
Working pressure 300Bar 300Bar
Total rated duration 45min 60min
Cylinder volume 6L 9L
Cylinder material Steel Carbon composite
Weight <15kg <12kg
Storage temperature -30°C to +65°C -30°C to +65°C
Operating temperature -10°C to +60°C -10°C to +60°C
Storage lifetime 10 years 10 years
  • Self-contained open-circuit compressed air breathing apparatus with positive pressure full face mask; apparatus for fire-fighting of Type 2 tested to EN 137 (2006) and EN 136 (1998) incl. AC (1999) and AC (2003), ISO 23269-2:2011; certified to MED Directive 2014/90 and SOLAS requirements. Approved as breathing apparatus of the fire-fighter's outfit.
  • Not for use in accidents with cargoes. It is not a diving apparatus. Lalizas strongly recommends use by well-trained personnel only.
  • Durations estimated at an average consumption of 40L/min with a fully charged cylinder; workload, physical fitness, restrictive clothing, emotional stress and fatigue increase consumption.
  • Each SCBA shall be used with an approved lifeline as part of the fire-fighter's outfit (FSS Code Ch.3.2.1.3), attachable by snap-hook to the harness or a separate belt.

Main Components

  • Back frame: donning cushion harness, adjustable cylinder holding Velcro webbing, rubber pad, two grooves for the high and medium pressure hoses. Flame retardant, waterproof and antistatic.
  • First stage regulator: reduces 300bar to a constant ≈7bar and a flow of >350L/min; relief valve opens above 11bar; G5/8 connecting thread (EN144-2). High pressure hose (WP 300Bar) to the pressure gauge (0–40Mpa / 400Bar, readable to 1Mpa / 10bar) and warning whistle (sounds below 50-60bar, >90dB (A)); medium pressure hose (WP 20Bar) to the second stage.
  • Second stage regulator: "on demand" valve with ON & OFF buttons, fast joint on its hose, plug-in interface to the face piece, 360º rotation at the mask joint.
  • Face piece: Class 3 mask for special use per EN 136:1998 + AC (2003) – visor, speech diaphragm, exhalation valve, plug-in interface, rubber straps, sealing edge, head net. Leakage requirements are unlikely to be met if facial hair or spectacle side arms pass under the facial seal.

Cylinder & Valve

  • 71327: steel cylinder 6L, working pressure 300bar (EN 1964-1).
  • 71328: composite cylinder 9L, working pressure 300bar (EN 1975 & EN 12245).
  • Cylinder thread for both models 18x1, 5mm (EN 144-1) (as printed); colour coded for breathing air per EN 1089-3:2001.
  • Cylinder valve: inlet M18X 1, 5mm (EN 144-1), outlet G5/8 (EN 144-2), working pressure 30MPa, relief valve, rubber knob operable while wearing; the spindle cannot be completely unscrewed in normal operation.
  • If you do not use a Lalizas cylinder: it must be designed to national regulations, hold at least 1200 liter of air, and be marked with charging pressure, capacity and the inspection body stamp; the complete apparatus shall undergo practical performance tests.
  • Supplied in heavy duty plastic carrying suitcases.

Brief Check Before Use

  1. Remove the SCBA from the suitcase.
  2. Push the face piece lock button and detach the second stage regulator from the face piece.
  3. Push the "OFF" button of the second stage regulator.
  4. Open the cylinder valve until you hear the whistle and the gauge stabilises: it must read at least 80% of the rated filling pressure (300bar), i.e. 240-300bar (±10% with ambient temperature). Close the valve and watch the gauge for 60 sec: a drop of 20bar or less (printed "20dar") means the system is leak-tight; more than 20bar → send it to a Lalizas authorized service station.
  5. Put the second stage regulator to your mouth and inhale to check the on demand valve; the whistle sounds again – check the gauge reads approximately 50 bar when it sounds.
  6. When the gauge reads zero, detach the second stage regulator from the first stage at the fast joint.
  7. Check the second stage O-ring, the visor and the sealing edge for damage.
  8. Assemble the second stage regulator to the face piece and don the face piece.
  9. Plug the tube entrance with your finger and inhale: the face piece should deform towards your face. Any deficiency → authorized service station.
  10. Doff the face piece and reconnect the second stage regulator to the first stage at the fast joint. The SCBA is ready to use or to pack for storage.

Fitting & Use

  1. Harness: don it like a jacket, no twisted harness or hose; adjust the shoulder straps tight but comfortable; close the waist belt buckle and fasten the strap.
  2. Push the "OFF" button of the second stage regulator.
  3. Open the cylinder valve slowly counterclockwise until fully open; listen for the whistle and check 240-300bar (at least 80%). Take extra care to have the cylinder valve fully opened during use.
  4. Face mask: fully extend the straps; place the lower strap over your head; pull the head-net on top of the face piece; fit the sealing edge to your face and pull the head net over the head with its loop; tighten the side straps – do not over-tighten, this can distort the seal; breathe freely.
  5. Seal check: take a breath and hold it, feel the flow stop, insert a finger under the seal – the demand valve should give steady flow again; remove the finger and let the mask reseal.
  6. Ambient air breathing: press the lock button, detach the second stage regulator and press "OFF"; reattach it to have device air again immediately.

Doffing & After Use

  • Check how much air is left and close the cylinder valve; below 80% (240-300bar) the cylinder needs refilling.
  • Pull the metal buckles forward to release the head-net straps and remove the face piece.
  • Release the waist belt, slacken the shoulder straps and remove the apparatus.
  • Cylinder change: open the Velcro webbing and unscrew the hand-wheel connector; mark the cylinder empty or half load and send it for charging; fit the rubber protection cover on the first stage regulator. To fit a charged Lalizas cylinder (6L 300bar or 9L 300bar): place it in the webbing, remove the cover, align and screw the valve to the first stage hand wheel, fasten the webbing.
  • After every use clean and visually inspect the apparatus; reassemble and pack when all components are thoroughly dry.

Maintenance and Service

Action After use Every month Every 4 months Every 1 year * Every 2 years Every 5 years
Clean and disinfect as necessary (A) X
Visual inspection (B) X X
Charge cylinder to correct pressure (C) X
Function test (E) X X
Check manufacturing date of the cylinder X X
Check cylinder pressure X X
Service (authorized service station) X
Air replacement (authorized service station) X
Hydraulic test (D) (authorized service station) X

* or more frequently in case of severe use.

  • Cleaning (A): no organic solvents (acetone, white spirit, trichloroethylene or similar); do not immerse the apparatus. Back frame and straps: brush or sponge with warm soapy water, rinse, dry in clean air away from heat and sunlight. Cylinder, valve and regulators: wet cloth in hot water, then dry cloth.
  • Face piece: warm fresh water (maximum 43ºC) and neutral soap, rinse, shake and dry with a cotton cloth or clean gauze (not ginned cotton); disinfect mask and sealing edge with a cotton cloth moistened in 70% isopropyl alcohol and let it evaporate away from heat and sunlight.
  • Visual inspection (B): face piece and on demand valve; cylinder valve, regulator, hose, gauge and connections; straps and buckles. Don and check the straps; check visor, sealing edge, head net and rubber straps; check the second stage for wear and the ON-OFF buttons; remove the cylinder, release the remaining air and recharge to 300bar.
  • Charging (C): air to EN12021; cylinder to national standards with original test date and mark; hydraulic test (D) every five years after manufacture not exceeded. Open the valve, connect the G5/8 hand wheel of the charging hose, set the compressor to 300 bar; assemble to the apparatus 24 hours after charging; with "OFF" pushed, open the valve for 15 sec to check pressure, first stage and whistle; about 300 bar steady for 20 sec, then push "ON" to vent (search for a leak if it does not stay steady). Close the valve, vent and remove the hose, refit the plug, repack.
  • Function test (E): see the pre-use check; it should last only a few seconds.
  • Storage: clean, dry, away from direct heat, dust, sunlight, extreme cold and damaging chemicals; not compressed; storage temperature -30ºC to +65ºC. Transport tightly packed in a strong box.
  • Life expectancy: 10 years from date of manufacture when maintained per the instructions and national regulations and serviced annually by a Lalizas authorized service station (or more frequently in severe use).

Lalizas safety notification: to be used only by well-trained personnel following the manufacturer's instructions; misuse can lead to injuries or even death; non-trained personnel must not use the respirators, either for safety or training. If something is not clear, do not use the equipment and contact a Lalizas representative / service station.