Instructions of use for the Lalizas Self-Contained Breathing Apparatus SOLAS/MED 71327 (6L) and 71328 (9L): components, technical data, pre-use checks, donning and doffing, cylinder change, service intervals, charging and storage.

Technical Data
| Item | 71327 | 71328 |
|---|---|---|
| Type | Open circuit, positive pressure | Open circuit, positive pressure |
| Air supply | On demand | On demand |
| Warning pressure | 50-60Bar | 50-60Bar |
| Working pressure | 300Bar | 300Bar |
| Total rated duration | 45min | 60min |
| Cylinder volume | 6L | 9L |
| Cylinder material | Steel | Carbon composite |
| Weight | <15kg | <12kg |
| Storage temperature | -30°C to +65°C | -30°C to +65°C |
| Operating temperature | -10°C to +60°C | -10°C to +60°C |
| Storage lifetime | 10 years | 10 years |
- Self-contained open-circuit compressed air breathing apparatus with positive pressure full face mask; apparatus for fire-fighting of Type 2 tested to EN 137 (2006) and EN 136 (1998) incl. AC (1999) and AC (2003), ISO 23269-2:2011; certified to MED Directive 2014/90 and SOLAS requirements. Approved as breathing apparatus of the fire-fighter's outfit.
- Not for use in accidents with cargoes. It is not a diving apparatus. Lalizas strongly recommends use by well-trained personnel only.
- Durations estimated at an average consumption of 40L/min with a fully charged cylinder; workload, physical fitness, restrictive clothing, emotional stress and fatigue increase consumption.
- Each SCBA shall be used with an approved lifeline as part of the fire-fighter's outfit (FSS Code Ch.3.2.1.3), attachable by snap-hook to the harness or a separate belt.
Main Components
- Back frame: donning cushion harness, adjustable cylinder holding Velcro webbing, rubber pad, two grooves for the high and medium pressure hoses. Flame retardant, waterproof and antistatic.
- First stage regulator: reduces 300bar to a constant ≈7bar and a flow of >350L/min; relief valve opens above 11bar; G5/8 connecting thread (EN144-2). High pressure hose (WP 300Bar) to the pressure gauge (0–40Mpa / 400Bar, readable to 1Mpa / 10bar) and warning whistle (sounds below 50-60bar, >90dB (A)); medium pressure hose (WP 20Bar) to the second stage.
- Second stage regulator: "on demand" valve with ON & OFF buttons, fast joint on its hose, plug-in interface to the face piece, 360º rotation at the mask joint.
- Face piece: Class 3 mask for special use per EN 136:1998 + AC (2003) – visor, speech diaphragm, exhalation valve, plug-in interface, rubber straps, sealing edge, head net. Leakage requirements are unlikely to be met if facial hair or spectacle side arms pass under the facial seal.
Cylinder & Valve
- 71327: steel cylinder 6L, working pressure 300bar (EN 1964-1).
- 71328: composite cylinder 9L, working pressure 300bar (EN 1975 & EN 12245).
- Cylinder thread for both models 18x1, 5mm (EN 144-1) (as printed); colour coded for breathing air per EN 1089-3:2001.
- Cylinder valve: inlet M18X 1, 5mm (EN 144-1), outlet G5/8 (EN 144-2), working pressure 30MPa, relief valve, rubber knob operable while wearing; the spindle cannot be completely unscrewed in normal operation.
- If you do not use a Lalizas cylinder: it must be designed to national regulations, hold at least 1200 liter of air, and be marked with charging pressure, capacity and the inspection body stamp; the complete apparatus shall undergo practical performance tests.
- Supplied in heavy duty plastic carrying suitcases.
Brief Check Before Use
- Remove the SCBA from the suitcase.
- Push the face piece lock button and detach the second stage regulator from the face piece.
- Push the "OFF" button of the second stage regulator.
- Open the cylinder valve until you hear the whistle and the gauge stabilises: it must read at least 80% of the rated filling pressure (300bar), i.e. 240-300bar (±10% with ambient temperature). Close the valve and watch the gauge for 60 sec: a drop of 20bar or less (printed "20dar") means the system is leak-tight; more than 20bar → send it to a Lalizas authorized service station.
- Put the second stage regulator to your mouth and inhale to check the on demand valve; the whistle sounds again – check the gauge reads approximately 50 bar when it sounds.
- When the gauge reads zero, detach the second stage regulator from the first stage at the fast joint.
- Check the second stage O-ring, the visor and the sealing edge for damage.
- Assemble the second stage regulator to the face piece and don the face piece.
- Plug the tube entrance with your finger and inhale: the face piece should deform towards your face. Any deficiency → authorized service station.
- Doff the face piece and reconnect the second stage regulator to the first stage at the fast joint. The SCBA is ready to use or to pack for storage.
Fitting & Use
- Harness: don it like a jacket, no twisted harness or hose; adjust the shoulder straps tight but comfortable; close the waist belt buckle and fasten the strap.
- Push the "OFF" button of the second stage regulator.
- Open the cylinder valve slowly counterclockwise until fully open; listen for the whistle and check 240-300bar (at least 80%). Take extra care to have the cylinder valve fully opened during use.
- Face mask: fully extend the straps; place the lower strap over your head; pull the head-net on top of the face piece; fit the sealing edge to your face and pull the head net over the head with its loop; tighten the side straps – do not over-tighten, this can distort the seal; breathe freely.
- Seal check: take a breath and hold it, feel the flow stop, insert a finger under the seal – the demand valve should give steady flow again; remove the finger and let the mask reseal.
- Ambient air breathing: press the lock button, detach the second stage regulator and press "OFF"; reattach it to have device air again immediately.
Doffing & After Use
- Check how much air is left and close the cylinder valve; below 80% (240-300bar) the cylinder needs refilling.
- Pull the metal buckles forward to release the head-net straps and remove the face piece.
- Release the waist belt, slacken the shoulder straps and remove the apparatus.
- Cylinder change: open the Velcro webbing and unscrew the hand-wheel connector; mark the cylinder empty or half load and send it for charging; fit the rubber protection cover on the first stage regulator. To fit a charged Lalizas cylinder (6L 300bar or 9L 300bar): place it in the webbing, remove the cover, align and screw the valve to the first stage hand wheel, fasten the webbing.
- After every use clean and visually inspect the apparatus; reassemble and pack when all components are thoroughly dry.
Maintenance and Service
| Action | After use | Every month | Every 4 months | Every 1 year * | Every 2 years | Every 5 years |
|---|---|---|---|---|---|---|
| Clean and disinfect as necessary (A) | X | |||||
| Visual inspection (B) | X | X | ||||
| Charge cylinder to correct pressure (C) | X | |||||
| Function test (E) | X | X | ||||
| Check manufacturing date of the cylinder | X | X | ||||
| Check cylinder pressure | X | X | ||||
| Service (authorized service station) | X | |||||
| Air replacement (authorized service station) | X | |||||
| Hydraulic test (D) (authorized service station) | X |
* or more frequently in case of severe use.
- Cleaning (A): no organic solvents (acetone, white spirit, trichloroethylene or similar); do not immerse the apparatus. Back frame and straps: brush or sponge with warm soapy water, rinse, dry in clean air away from heat and sunlight. Cylinder, valve and regulators: wet cloth in hot water, then dry cloth.
- Face piece: warm fresh water (maximum 43ºC) and neutral soap, rinse, shake and dry with a cotton cloth or clean gauze (not ginned cotton); disinfect mask and sealing edge with a cotton cloth moistened in 70% isopropyl alcohol and let it evaporate away from heat and sunlight.
- Visual inspection (B): face piece and on demand valve; cylinder valve, regulator, hose, gauge and connections; straps and buckles. Don and check the straps; check visor, sealing edge, head net and rubber straps; check the second stage for wear and the ON-OFF buttons; remove the cylinder, release the remaining air and recharge to 300bar.
- Charging (C): air to EN12021; cylinder to national standards with original test date and mark; hydraulic test (D) every five years after manufacture not exceeded. Open the valve, connect the G5/8 hand wheel of the charging hose, set the compressor to 300 bar; assemble to the apparatus 24 hours after charging; with "OFF" pushed, open the valve for 15 sec to check pressure, first stage and whistle; about 300 bar steady for 20 sec, then push "ON" to vent (search for a leak if it does not stay steady). Close the valve, vent and remove the hose, refit the plug, repack.
- Function test (E): see the pre-use check; it should last only a few seconds.
- Storage: clean, dry, away from direct heat, dust, sunlight, extreme cold and damaging chemicals; not compressed; storage temperature -30ºC to +65ºC. Transport tightly packed in a strong box.
- Life expectancy: 10 years from date of manufacture when maintained per the instructions and national regulations and serviced annually by a Lalizas authorized service station (or more frequently in severe use).
Lalizas safety notification: to be used only by well-trained personnel following the manufacturer's instructions; misuse can lead to injuries or even death; non-trained personnel must not use the respirators, either for safety or training. If something is not clear, do not use the equipment and contact a Lalizas representative / service station.
Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.
Products in this Manual
-

Lalizas Self Contained Breathing Apparatus Solas/Med, Without Cylinder