Specifications
Electric 3500
|
3500 |
| Motor |
24 V DC, 1.5 kW nominal |
| Max pull |
1600 kg 3520 lb
|
| Max line speed |
4–16 m/min 13–52 ft/min
|
| Working load |
213 kg 469 lb
|
| Line speed at working load |
14 m/min 46 ft/min
|
| Weight, deck unit |
25 kg 55 lb
|
| Weight, motor/gearbox |
5 kg 11 lb (as printed) |
Hydraulic 3500
|
3500 |
| Motor |
80 cc/rev |
| Flow min/max |
10–40 l/min |
| Max pressure |
175 bar 2538 psi
|
| Max pull |
1300 kg / 2860 lb at 140 bar (2035 psi) 1600 kg / 3520 lb at 175 bar (2538 psi) |
| Max line speed |
8–29 m/min 26–95 ft/min
|
| Working load |
213 kg 496 lb (as printed)
|
| Line speed at working load |
Dependent on power pack |
| Weight, deck unit |
25 kg 55 lb
|
| Weight, motor/gearbox |
28 kg 62 lb
|
The electric specification lists only the 24 V motor, while the cable and breaker tables also cover 12 V systems (as printed).
Deck Unit
- Four items to place: deck unit, motor/gearbox, chain pipe (optional) and controls. Allow space below deck for the motor/gearbox (and the hydraulic lines on hydraulic models).
- Align the chain centre line on the gypsy with the bow roller in a horizontal plane, with the vertical line within 10 degrees of the gypsy.
- Chain contact on the gypsy: at least 120, preferably 180 degrees.
- Cut and drill the deck to the installation template; bed the windlass and chain pipe on bedding compound. Hydraulic models: gypsy pawl facing aft, chain stripper facing forward.
- Grease the drive shaft and bolt the motor/gearbox on squarely; pack out if the deck underside is not parallel to the gearbox flange.
Hydraulic Plumbing
- For Lewmar Commander power packs or similar packs giving the required flow and pressure.
- Flush the pipework before the final connection. If rotation is wrong, swap the A and B hoses, the switch wiring or the DCV caps.
- Hose bore: up to 20 l/min 1/2"; up to 40 l/min 3/4". Go up a size on runs over 5–7 m.
- A case drain line must be fitted: min bore 6 mm (1/4"), safe working pressure 18 bar (250 psi), ideally run to the reservoir separately.
- Fittings: motor ports 1/2" BSP female; case drain 1/4" BSP female.
- Switch supply 12 V or 24 V DC, minimum 3 amps.
Electrical Installation
- Follow the dual-direction or single-direction diagram for your system.
- Mount the control box within 1 meter of the motor, preferably dry.
- Fit the rubber boots before the final crimp, check against the diagram before powering up, and grease all terminals before fitting the boots.
- Connect the motor thermal cutout into the switch wiring: the motor warranty is void if it is not connected.
- Electric deck switches: 16/0.2 wire to the control box. Air deck switches: keep the breather hole under the switch clear of sealant.
- Fit an ON/OFF isolator to isolate the windlass when not in use and for maintenance.
- A voltage drop of more than 2 volts raises motor current, cuts performance and overheats the motor. Use PVC or butyl rubber insulated cable.
| System |
Battery to motor |
Cable mm² |
Wire (USA) |
| 12 V |
1–10 m |
35 |
1 |
| 12 V |
10–15 m |
50 |
1/0 |
| 12 V |
15–20 m |
70 |
2/0 |
| 24 V |
1–10 m |
25 |
3 |
| 24 V |
10–15 m |
35 |
1 |
| 24 V |
15–20 m |
50 |
1/0 |
Dual Direction, with Overload Protection
Single Direction Solenoid Box
Operation & Maintenance
The main shaft is splined to the capstan. The gypsy is either driven by the capstan through dog teeth or runs free on its full-wrap brake band; turning the top nut lifts or lowers the capstan to engage or release the dog drive. A pawl locks the gypsy for short periods when the capstan is used alone.
Using It
-
Power up/down: brake band and pawl released, dog drive fully engaged.
-
Manual chain release: secure the gypsy with a winch handle in the brake band bi-square, raise the capstan with the handle in the top nut until the dog drive is clear, then ease the brake to let the chain run; tighten the brake to slow or stop it.
-
Capstan (rope only): lock the gypsy with the brake band or pawl, raise the capstan to disengage the dog drive, press Up.
-
Re-engaging the dog drive: lower the capstan onto the gypsy until it resists, back off a quarter turn, press Up/Down so it springs into engagement, tighten the top nut if needed, then release the brake band or pawl.
Safety & Maintenance
- Never power in or out without the dog drive fully engaged; keep clear of free-running chain; never leave a winch handle in the windlass.
- Hold the chain at anchor on a stopper or strong point; tie off the anchor when the windlass is not in use. Use the engine to help recovery and never exceed the rated load.
- Every six months: wash off salt with fresh water, clean and grease the main shaft, spline and bearings with marine grease.
- Remove and clean the brake band and gypsy (no grease on the band surface); replace if worn.
- Clean and repaint any corrosion on the motor/gearbox with marine oil-based enamel.
3500 Anchor Windlass Parts List

Stripper (item 7) and gypsy (item 9) carry no part number in the list; the gypsy kit depends on your chain (see the chain chart). B0537 is printed for both the M8 × 100 screw and the M12 washer.
Gypsy Kits
| Gypsy ident no. |
Gypsy kit no. |
| 351 |
68000574 |
| 352 |
68000575 |
| 353 |
68000576 |
| 354 |
68000577 |
Remote Chain Pipes
| Lewmar part no. |
Description |
|
| 68000037 |
14–16 mm remote chain pipe (CH) |
View part → |
| Lewmar part no. |
Description |
| 68000024 |
8–13 mm remote chain pipe |
| 68000314 |
14–16 mm remote chain pipe (BR) |
Dimensions
Electric (24 V)
Hydraulic
The manual refers to an installation template for the deck cut-outs; it is not included in this PDF.