Specification

Operating voltage 9 V to 28 V DC only
Max switching current 5 A resistive, 2.75 A inductive (L/R 0.026)
Switch type Normally-open, momentary contact
Wire size 1 mm²
Contact life 100,000 operations
Ingress protection IP67 above deck, IP65 below deck (subject to installation)

For Lewmar 12V and 24V DC product control systems. Wiring: two white leads to the momentary normally-open contact, 5 A max.

Models

Part no. Model
48000258 Custom Deck Switch Open, blasted View switch →
48000259 Custom Deck Switch Closed, blasted View switch →
48000256 Custom Deck Switch Open, polished View switch →
48000257 Custom Deck Switch Closed, polished View switch →

Installation

  • Electrical work by a qualified electrician, with power isolated.
  • Fit to a flat surface within ±1 mm. Drill a 25 mm (1") central hole through the deck using the supplied template.
  • Mark and drill the fixing holes; screw or bolt heads must be countersunk to sit flush in the switch.
  • Bed with a sealing compound that keeps IP67 and survives the environment; tighten all 3 fixings evenly, not over-tight.
  • DC systems only; follow ISO 10133 as a minimum, and for AC circuits on board. Not for ignition-protected areas.

Operation and Care

  • Operate with fingers, bare feet or soft-soled shoes only. The open version can be pressed through the lid; on the closed version lift the lid to use it by foot and close it afterwards.
  • Leave the lid closed. Isolate powered deck equipment when not in use.
  • No power washers, and no direct hose flow at the switch. Clean only with mild soap and a light fresh-water rinse.
  • Keep chemicals, deck cleaners, petroleum-based fluids, deck polish, brighteners, varnish, paint and oil off and away from the switch.

Before Every Trip

  • Test the switch and the equipment it controls under no load first.
  • No visible damage, wear, chips or cracks; rubber membrane not sticky, cracked or split.
  • A smooth, positive click; not spongy, no squelching or bubbling; no sign of water ingress.
  • Fixings and seal to the deck secure. Any defect: do not use, replace the switch.

Annually

  • A qualified technician removes the switch and repeats all checks, inspects the underside for corrosion or water and checks the wiring.
  • Open circuit (OFF): no measurable continuity. Closed circuit (ON): less than 3 Ω.
  • Expect a service life of 3 to 5 years from purchase, depending on UV, weather and use.
  • Brief the crew on the three ways to isolate the equipment: the switch, the panel circuit breaker and the main battery isolator.

Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.